(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Sehubungan dengan adanya Peraturan Baru Kementerian Perdagangan No.36 Tahun 2023 tentang Pembatasan Impor Barang, MISUMI Indonesia melakukan tindakan pencegahan. Lihat informasi detailnya di sini
    Due to New Regulation of Ministry Of Trade No.36 of 2023 concerning retrictions on imports of goods, MISUMI Indonesia do precautions measure. See detail information here
  • Nomor telepon alternatif Kontak Layanan Pelanggan : 021-29182911| 021-29182991 | 021-29182997 | 021-29182998
    Alternative telephone number Contact Customer Service: 021-29182911 | 021-29182991 | 021-29182997 | 021-29182998

Cable KQE 60 V Cross-linked Polyethylene Insulation

Cable KQE 60 V Cross-linked Polyethylene Insulation

Click this image to zoom it.

Move the mouse over the image to zoom

• KQE Low voltage single core cable.
• Conductor structure is Tin Plated Annealed Copper Stranded Wire
• Insulated cable is Cross-linked Polyethylene material as RoHS complied wires.
• 60V cable for weak current circuit.
• Operating temperature range is 0-80℃.
• 6 cable colors are available W (White), BK (Black), R (Red), BE (Blue), Y (Yellow) and GN (Green)
• Can order cable for 4 sizes of length. (10m, 50m, 100m and 400m)
• Minimum bending radius is 8 times of finished outer diameter. (Fixed Part Only)

  • Strand Wire
  • Less than 100 V

● Does not melt under heat of soldering irons or similar and allows for easy connection of electric device wiring.


·Be careful not to confuse total length and quantity when ordering.

The Electrical Appliance and Material Safety Law certificate has not been obtained.

PDF

Part Number

Configured Part Number is shown.

Specifications

KQE 60 V Cross-linked Polyethylene Insulation:Related Image

ModelSection Area
KQE0.2*(AWG24)
00.3 * (AWG22)
00.5 * (AWG20)
0.75 * (AWG18)
* (~ mm2) is to be used only as an estimated section area. Refer to the comparison table on >>Click here for details.


Be sure to read the following precautions when you place an order.
* Length in "m" is included in our part numbers. Always specify quantity as number of units, not as meters.

More Information

KQE 60 V Cross-linked Polyethylene Insulation:Related Image

Operating Temperature Range0 ~ 80°C
BendingFinished Outer Diameter x 8 (Fixed Part Only)
 
ModelSection Area
(mm2)
ColorTotal Length
(m)
ConductorPolyethylene
Insulator Thickness
(mm)
Finished Outer Diameter
Approx. (mm)
Electrical PropertiesApproximate Weight
(kg/km)
Structure
(Strands / mm)
Outer Diameter
(mm)
Conductor Resistance
Ω / km (20°C)
Insulation Properties
MΩkm (20°C)
Test Voltage
V / Min
Allowable Current
A (30°C)
KQE0.2 *(AWG24)W (White)
BK (Black)
R (Red)
BE (Blue)
Y (Yellow)
GN (Green)
10
/
50
/
100
/
400
(1 Roll)
7/0.180.540.2511112500200042.5
0.3 * (AWG22)12/0.180.70.31.364.4200074
0.5 * (AWG20)20/0.1810.31.5538.7150096
0.75 * (AWG18)30/0.181.10.31.725.81000129
* AWG size (AWG ~ ) is to be used only as a guide. Refer to the comparison table on >>Click here for details. * Allowable current is to be used only as a reference value and is not guaranteed.
* For the outer diameter size of cables, wire sheath (coat), etc., refer to "Finished Outer Diameter" in the table above. 
 
Structure Outline
ConductorTin Plated Annealed Copper Stranded Wire
InsulatorCross-linked Polyethylene
  
Current Reduction Factor
Ambient Temperature (°C)30405060
Current Reduction Factor1.000.900.770.63
Allowable current value indicates the calculated value of 1 cable laid aboveground in ambient temperature of 30°C, and is not a guaranteed value.
If the ambient temperature is 30 °C or above, the above current reduction factor is multiplied by the allowable current.
(Example) Allowable current value when the ambient temperature is 40 °C at 0.2mm2
4 x 0.9 = 3.6 (A)  
 
Package Type
Vinyl Bag: The wires are wound into a bundle and tied with rope or vinyl string and then packed in a vinyl bag.
Case: The wires are wound into a bundle and tied with string etc., and packed in a case (cardboard box).
ModelSection AreaTotal Length
400 m (1 roll)100m50m10m
KQE0.2 *(AWG24)Vinyl Bag (Case)Vinyl Bag (Case)Vinyl Bag (Case)Vinyl Bag (Case)
0.3 * (AWG22)Vinyl Bag (Case)Vinyl Bag (Case)Vinyl Bag (Case)Vinyl Bag (Case)
0.5 * (AWG20)Vinyl Bag (Case)Vinyl Bag (Case)Vinyl Bag (Case)Vinyl Bag (Case)
0.75 * (AWG18)Vinyl Bag (Case)Vinyl Bag (Case)Vinyl Bag (Case)Vinyl Bag (Case)
* AWG size (AWG ~ ) is to be used only as a guide. Refer to the comparison table on >>Click here for details.

Part Number
KQE-0.75-R-10
KQE-0.75-R-50
KQE-0.75-R-100
KQE-0.75-R-400
Part NumberMinimum order quantityVolume DiscountDays to ShipRoHSOverall Length
(m)
1 Piece(s) 16 Day(s) or more 1010
1 Piece(s) 16 Day(s) or more 1050
1 Piece(s) 16 Day(s) or more 10100
1 Piece(s) 16 Day(s) or more 10400

Loading...

  1. 1

Basic Information

Conductor Cross Section(mm2) 0.75 AWG size(AWG) 18 Number Of Cores(Core) 1
Finished outer diameter(mm) 1.7 Rated Voltage For Low Current Circuits Shield None
Sheath (outer coating) color Red Sheath (outer coating) material Polyethylene-Based Power supply/signal Dual use

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:021-8990-4102 / FAX:021-8990-5803
8:30am - 5:30pm (Monday - Friday)