Process Valve, 2 Port Valve For Compressed Air And Air-Hydro Circuit Control VNA Series (Part Numbers)

Process Valve, 2 Port Valve For Compressed Air And Air-Hydro Circuit Control VNA Series

A 2 port valve for compressed air and air-hydro circuit control made by SMC.
[Features]
· A universal 2 port valve exclusively for controlling air pressure systems and air-hydro circuits
· Cylinder actuation by external pilot air
· Balance poppet type that allows normal and reverse flow
· Can be operated at 0 MPa
· Wide variations

(i)Caution

  • Product images may be representative images. Refer to the catalog for details.

PDF

Process Valve, 2 Port Valve For Air-Hydro Circuit Control VNA Series Specifications

VNA Series external pilot solenoid type external appearance

VNA Series external pilot solenoid type external appearance

VNA Series air-operated type external appearance

VNA Series air-operated type external appearance

VNA□01 JIS symbol

VNA□01 JIS symbol

VNA□02 JIS symbol

VNA□02 JIS symbol

VNA□03 JIS symbol

VNA□03 JIS symbol

VNA□11 JIS symbol

VNA□11 JIS symbol

Fluid TemperatureVNA□□□A*1 -5 to +60°C
VNA□□□B
VNA□□□C
*1: -5 to +99°C
(air-operated type only)
Ambient Temperature*1 -5 to +50°C (60°C for air-operated type)
Proof Pressure1.5 MPa
Operating Pressure Range0 to 1 MPa
External Pilot AirPressure Range0.2 to 0.7 MPa
LubricationNot required (if lubricating, use turbine oil class 1 ISO VG32 *2)
Temperature*1: -5 to +50°C (60°C for air-operated type)
Mounting Orientation*3: Unrestricted

*1: No freezing.
*2: Do not lubricate if seal material is EPR.
*3: However, if the external pilot is a solenoid type, SMC recommends mounting the pilot solenoid valve in an upward facing vertical or horizontal orientation.

Model

ModelPiping Connection Port Diameter
Thread
Orifice Diameter
ø(mm)
Flow Rate CharacteristicsWeight (kg)
Measured with AirMeasured with Water*
C
(dm3/(bar·sec)]
bCvKvConversion CvAir Operated TypeExternal Pilot Solenoid Type
VNA1□□□-6A1/8103.50.350.880.91.00.10.2
VNA1□□□-8A1/45.90.241.51.51.7
VNA1□□□-10A3/87.90.161.91.82.1
VNA2□□□-10A15160.353.83.94.50.30.4
VNA2□□□-15A1/2230.254.84.65.4
VNA3□□□-20A3/420340.167.57.58.70.50.6

*This product cannot be used for water.

ModelPiping Connection Port Diameter
Thread
Orifice Diameter
ø(mm)
Flow Rate CharacteristicsWeight (kg)
Measured with AirMeasured with WaterAir Operated TypeExternal Pilot Solenoid Type
Effective Area
(mm2)
KvConversion Cv
VNA4□□□-25A12522010.4120.80.9
VNA5□□□-32A1 1/43232015.6181.31.4
VNA6□□□-40A1 1/24050024.2282.12.2
VNA7□□□-50A25077037.2433.13.2

Pilot Solenoid Valve Specifications

Piping Connection Port Diameter6A to 25A32 A to 50 A
Pilot Solenoid ValveSF4-□□□-23
SF4-□D-23-Q
SF4-□DZ-23-Q
VO307-□□□1
VO307-□D1-Q
VO307-□DZ1-Q
Electrical EntryGrommet, grommet terminal
Conduit terminal
DIN Terminal
Grommet, DIN terminal
Coil Rated Voltage (V)AC (50/60 Hz)100 V, 200 V, other (semi-standard)
DC24 V, other (semi-standard)
Allowable Voltage Fluctuation-15 to +10% of rated voltage
Temperature rise value35°C or less (when rated voltage is applied)50℃ or less (when rated voltage is applied)
Apparent PowerACInrush5.6 VA (50 Hz), 5.0 VA (60 Hz)12.7 VA (50 Hz), 10.7 VA (60 Hz)
Holding3.4 VA (50 Hz), 2.3 VA (60 Hz)7.6 VA (50 Hz), 5.4 VA (60 Hz)
Power ConsumptionDC1.8 W (without indicator light), 2 W (with indicator light)4 W (without indicator light), 4.2 W (with indicator light)
Manual OperationNon-locking push type
Other (semi-standard)
Non-locking push type

*See catalog for information on ordering pilot solenoid valves.

Diagram

VNA Series diagram

VNA Series diagram

Component Parts

NumberPart NameMaterialNotes
1BodyAluminum alloyPlatinum silver coated
2Cover AssemblyAluminum alloyPlatinum silver coated
*3Plate AssemblyAluminum alloySeal material (NBR, FKM, EPR)
*4Valve ElementAluminum alloySeal materials (NBR, FKM, EPR)
5Piston AssemblyAluminum alloy-
6Travel SpringStainless steel-
7Return SpringPiano wire-
8Pilot Solenoid Valve--

*Parts 3 and 4 are for selection of valve composition.

Operating Principle

For VNA□01□, □11□ (N.C. Type)

  • When pilot solenoid valve 8 is not energized (or when air is exhausted from 12 (P1) port of the air operated type), valve 4 linked to piston 5 is closed via the action of the return spring 7.

For Opening the Valve

  • When the pilot solenoid valve is energized (or when pressurized air enters through port 12 (P1) of the air operated type), the pilot air that has entered under the piston moves upward, opening the valve.

For Closing the Valve

  • When the power to the pilot solenoid valve is cut (or when fluid is exhausted from port 12 (P1) of the air operated type), the pilot air under the piston is exhausted and the valve closed via the action of the return spring.

For VNA□02□, □12□ (N.C. Type)

  • In contrast for the N.C. type, when the power to the pilot solenoid valve is shut off (or when air is exhausted from port 10 (P2) of the air operated type), unenergized, the valve is held open via the return spring. When the pilot solenoid valve is energized (or when pressurized air enters through port 10 (P2) of the air operated type), the valve closes.

VNA□03□ (C.O. Type)

  • The valve of the C.O. type, which has no return spring, is in an arbitrary position when air is exhausted through ports 12 (P1) and 10 (P2). When pressurized air enters port 12 (P1) (exhaust from port 10 [P2]), the valve opens. The valve closes when pressurized air enters port 10 (P2) (exhaust from port 12 [P1]).

Drawing

 

(Units: mm)

 

Piping connection port diameter: 6A, 8A, 10A dimensional drawing

Piping connection port diameter: 6A, 8A, 10A dimensional drawing

*10 mm longer for EZ and TZ, and 17 mm longer for DZ.

  • VNA1□□□-6A main port 1 (A), 2 (B): 1/8
  • VNA1□□□-8A main port 1 (A), 2 (B): 1/4
  • VNA1□□□-10A main port 1 (A), 2 (B): 3/8

 

(Units: mm)

 

Piping connection port diameter: 10A, 15A, 20A, 25A dimensional drawing

Piping connection port diameter: 10A, 15A, 20A, 25A dimensional drawing

*10 mm longer for EZ and TZ, and 17 mm longer for DZ.

 

(Units: mm)

 

ModelMain Port
1 (A), 2 (B)
ABCDEFGHIJKLMNPQRSTU
VNA2□□□-10A3/86342291472.580.5758084.5124125.5144.552264.524.32.3253455
VNA2□□□-15A1/2
VNA3□□□-20A3/480503517.58492848993.5135.513715662315.528.32.3304360.5
VNA4□□□-25A190604020100108909599.5151.515317272366.533.32.3354973

 

(Units: mm)

 

Piping connection port diameter: 32A, 40A, 50A dimensional drawing

Piping connection port diameter: 32A, 40A, 50A dimensional drawing

 

(Units: mm)

 

ModelMain Port
1 (A), 2 (B)
Pilot Port
12 (P1), 10 (P2)
ABCDEFGHIJ
VNA5□□□-32A1 1/41/8105775326.5120.520129.5170.1211.555
VNA6□□□-40A1 1/21/412096603013724147187.622963
VNA7□□□-50A21/4140113743716024170210.625274

*See the SMC catalog for information other than that detailed above.

Part Number
VNA411B-F25A-5DZ-Q
VNA412A-25A-2G
VNA412A-25A-3DZA
VNA412A-25A-4TZ
VNA412A-25A-5DZ
VNA412A-25A-5E
VNA412A-25A-5GA-B
VNA412A-25A-5GB
VNA412A-F25A-5D-Q
VNA412A-T25A-5D
VNA412B-25A-5D
VNA412B-F25A-5DZ-Q
VNA501A-32A
VNA501A-N32A
VNA502A-32A
VNA502A-N32A
VNA503A-32A
VNA511A-32A-1D
VNA511A-32A-1DZ
VNA511A-32A-2GS
VNA511A-32A-3DZ
VNA511A-32A-3G
VNA511A-32A-3GS
VNA511A-32A-4G
VNA511A-32A-5D
VNA511A-32A-5DZ
VNA511A-32A-5G
VNA511B-F32A-5D
VNA512A-F32A-6D
VNA601A-40A
VNA601A-F40A
VNA601A-N40A
VNA601B-40A
VNA603A-40A
VNA611A-40A-1DZ
VNA611A-40A-3DZ
VNA611A-40A-4D
VNA611A-40A-4DZ-Q
VNA611A-40A-4G
VNA611A-40A-5D
VNA611A-40A-5DZ
VNA611A-40A-5G
VNA611A-F40A-5D-Q
VNA611A-N40A-4D
VNA611B-40A-3G
VNA611B-40A-5DZ
VNA611B-40A-5G
VNA611B-40A-5GS
VNA611B-F40A-5DZ
VNA612A-40A-4DZ
VNA612A-40A-5DZ
VNA612B-40A-4DZ
VNA701A-50A
VNA702A-50A
VNA711A-50A-3D
VNA711A-50A-4D
VNA711A-50A-4G
VNA711A-50A-5DZ
VNA711A-50A-5G
VNA711A-F50A-4DZ
VNA711A-F50A-5DZ-Q
VNA711A-F50A-5G
VNA712A-50A-1G
VNA712A-50A-5G
VNA712A-F50A-4DZ
VNA712A-T50A-5D
Part NumberMinimum order quantityVolume DiscountDays to ShipType Applicable Fluid Switching Type Connection Type Plumbing Thread Nominal Driving Type Orifice Dia.
(Ø)
Operating Temperature Range
(°C)
Number of Solenoids Voltage Sealing materials Bracket Functions CE compliant Lead wire electrical entry Manual operation type
1 Piece(s) 15 Day(s) Electromagnetic TypeOilNormally ClosedG1Pilot Type--5~50Single Solenoid-FKMNone-CE-compliant productDIN terminal with light and surge voltage suppressorNon-locking, push type
1 Piece(s) 31 Day(s) Electromagnetic TypeAir / Oil / GasNormally Open[Rc (R)] Rc1Pilot Type25-5~50Single Solenoid200 V AC 50/60 HzNBRNoneNone-GrommetNon-locking, push type
1 Piece(s) 15 Day(s) Electromagnetic TypeAir / Oil / GasNormally Open[Rc (R)] Rc1Pilot Type--5~50Single Solenoid110 V AC 50/60 HzNBRNone-Not compatibleDIN terminal with light and surge voltage suppressorNon-locking, push type A (projecting)
1 Piece(s) 15 Day(s) Electromagnetic TypeAir / Oil / GasNormally Open[Rc (R)] Rc1Pilot Type--5~50Single Solenoid220 V AC 50/60 HzNBRNone-Not compatibleConduit terminal with light and surge voltage suppressorNon-locking, push type
1 Piece(s) 31 Day(s) Electromagnetic TypeAir / Oil / GasNormally Open[Rc (R)] Rc1Pilot Type25-5~50Single Solenoid24 V DCNBRNoneNone-DIN terminal with light and surge voltage suppressorNon-locking, push type
1 Piece(s) 15 Day(s) Electromagnetic TypeAir / Oil / GasNormally Open[Rc (R)] Rc1Pilot Type--5~50Single Solenoid-NBRNone-Not compatibleGrommet terminalNon-locking, push type
1 Piece(s) 15 Day(s) Electromagnetic TypeAir / Oil / GasNormally Open[Rc (R)] Rc1Pilot Type--5~50Single Solenoid-NBRIncluded-Not compatibleGrommetNon-locking, push type A (projecting)
1 Piece(s) 15 Day(s) Electromagnetic TypeAir / Oil / GasNormally Open[Rc (R)] Rc1Pilot Type--5~50Single Solenoid-NBRNone-Not compatibleGrommetLocking type B (tool required)
1 Piece(s) 15 Day(s) Electromagnetic TypeAir / Oil / GasNormally OpenG1Pilot Type--5~50Single Solenoid-NBRNone-CE-compliant productDIN terminalNon-locking, push type
1 Piece(s) 15 Day(s) Electromagnetic TypeAir / Oil / GasNormally OpenNPTF1Pilot Type--5~50Single Solenoid-NBRNone-Not compatibleDIN terminalNon-locking, push type
1 Piece(s) 20 Day(s) Electromagnetic TypeOil / GasNormally Open[Rc (R)] Rc1Pilot Type25-5~50Single Solenoid24 V DCFKMNoneNone-DIN terminalNon-locking, push type
1 Piece(s) 15 Day(s) Electromagnetic TypeOilNormally OpenG1Pilot Type--5~50Single Solenoid-FKMNone-CE-compliant productDIN terminal with light and surge voltage suppressorNon-locking, push type
1 Piece(s) 31 Day(s) Air Operating TypeAir / Oil / GasNormally Closed[Rc (R)] Rc1 1/4Pilot Type32-5~60--NBRNoneNone-NoneNon-locking, push type
1 Piece(s) 31 Day(s) Air Operating TypeAir / Oil / GasNormally ClosedNPT1 1/4Pilot Type32-5~60--NBRNoneNone-NoneNon-locking, push type
1 Piece(s) 31 Day(s) Air Operating TypeAir / Oil / GasNormally Open[Rc (R)] Rc1 1/4Pilot Type32-5~60--NBRNoneNone-NoneNon-locking, push type
1 Piece(s) 15 Day(s) Air Operating TypeAir / Oil / GasNormally OpenNPT1 1/4-32-5~60--NBRNone-Not compatibleNone-
1 Piece(s) 31 Day(s) Air Operating TypeAir / Oil / Gas[Others] Double acting[Rc (R)] Rc1 1/4Pilot Type32-5~60--NBRNoneNone-NoneNon-locking, push type
1 Piece(s) 20 Day(s) Electromagnetic TypeAir / Oil / GasNormally Closed[Rc (R)] Rc1 1/4Pilot Type32-5~50Single Solenoid100 V AC 50/60 HzNBRNoneNone-DIN terminalNon-locking, push type
1 Piece(s) 31 Day(s) Electromagnetic TypeAir / Oil / GasNormally Closed[Rc (R)] Rc1 1/4Pilot Type32-5~50Single Solenoid100 V AC 50/60 HzNBRNoneNone-DIN terminal with light and surge voltage suppressorNon-locking, push type
1 Piece(s) 15 Day(s) Electromagnetic TypeAir / Oil / GasNormally Closed[Rc (R)] Rc1 1/4Pilot Type32-5~50Single Solenoid200 V AC 50/60 HzNBRNone-Not compatible-Non-locking, push type
1 Piece(s) 31 Day(s) Electromagnetic TypeAir / Oil / GasNormally Closed[Rc (R)] Rc1 1/4Pilot Type32-5~50Single Solenoid110 V AC 50/60 HzNBRNoneNone-DIN terminal with light and surge voltage suppressorNon-locking, push type
1 Piece(s) 31 Day(s) Electromagnetic TypeAir / Oil / GasNormally Closed[Rc (R)] Rc1 1/4Pilot Type32-5~50Single Solenoid110 V AC 50/60 HzNBRNoneNone-GrommetNon-locking, push type
1 Piece(s) 15 Day(s) Electromagnetic TypeAir / Oil / GasNormally Closed[Rc (R)] Rc1 1/4Pilot Type32-5~50Single Solenoid110 V AC 50/60 HzNBRNone-Not compatible-Non-locking, push type
1 Piece(s) 31 Day(s) Electromagnetic TypeAir / Oil / GasNormally Closed[Rc (R)] Rc1 1/4Pilot Type32-5~50Single Solenoid220 V AC 50/60 HzNBRNoneNone-GrommetNon-locking, push type
1 Piece(s) 20 Day(s) Electromagnetic TypeAir / Oil / GasNormally Closed[Rc (R)] Rc1 1/4Pilot Type32-5~50Single Solenoid24 V DCNBRNoneNone-DIN terminalNon-locking, push type
1 Piece(s) 31 Day(s) Electromagnetic TypeAir / Oil / GasNormally Closed[Rc (R)] Rc1 1/4Pilot Type32-5~50Single Solenoid24 V DCNBRNoneNone-DIN terminal with light and surge voltage suppressorNon-locking, push type
1 Piece(s) 31 Day(s) Electromagnetic TypeAir / Oil / GasNormally Closed[Rc (R)] Rc1 1/4Pilot Type32-5~50Single Solenoid24 V DCNBRNoneNone-GrommetNon-locking, push type
1 Piece(s) 15 Day(s) Electromagnetic TypeOilNormally ClosedG1 1/4Pilot Type32-5~50Single Solenoid-FKMNone-Not compatibleDIN terminalNon-locking, push type
1 Piece(s) 15 Day(s) Electromagnetic TypeAir / Oil / GasNormally OpenG1 1/4Pilot Type32-5~50Single Solenoid12 V DCNBRNone-Not compatibleDIN terminalNon-locking, push type
1 Piece(s) 20 Day(s) Air Operating TypeAir / Oil / GasNormally Closed[Rc (R)] Rc1 1/2Pilot Type40-5~60--NBRNoneNone-NoneNon-locking, push type
1 Piece(s) 20 Day(s) Air Operating TypeAir / Oil / GasNormally ClosedG1 1/2Pilot Type40-5~60--NBRNoneNone-NoneNon-locking, push type
1 Piece(s) 20 Day(s) Air Operating TypeAir / Oil / GasNormally ClosedNPT1 1/2Pilot Type40-5~60--NBRNoneNone-NoneNon-locking, push type
1 Piece(s) 20 Day(s) Air Operating TypeOil / GasNormally Closed[Rc (R)] Rc1 1/2Pilot Type40-5~60--FKMNoneNone-NoneNon-locking, push type
1 Piece(s) 20 Day(s) Air Operating TypeAir / Oil / Gas[Others] Double acting[Rc (R)] Rc1 1/2Pilot Type40-5~60--NBRNoneNone-NoneNon-locking, push type
1 Piece(s) 20 Day(s) Electromagnetic TypeAir / Oil / GasNormally Closed[Rc (R)] Rc1 1/2Pilot Type40-5~50Single Solenoid100 V AC 50/60 HzNBRNoneNone-DIN terminal with light and surge voltage suppressorNon-locking, push type
1 Piece(s) 20 Day(s) Electromagnetic TypeAir / Oil / GasNormally Closed[Rc (R)] Rc1 1/2Pilot Type40-5~50Single Solenoid110 V AC 50/60 HzNBRNoneNone-DIN terminal with light and surge voltage suppressorNon-locking, push type
1 Piece(s) 20 Day(s) Electromagnetic TypeAir / Oil / GasNormally Closed[Rc (R)] Rc1 1/2Pilot Type40-5~50Single Solenoid220 V AC 50/60 HzNBRNoneNone-DIN terminalNon-locking, push type
1 Piece(s) 15 Day(s) Electromagnetic TypeAir / Oil / GasNormally Closed[Rc (R)] Rc1 1/2Pilot Type40-5~50Single Solenoid220 V AC 50/60 HzNBRNone-CE-compliant productDIN terminal with light and surge voltage suppressorNon-locking, push type
1 Piece(s) 20 Day(s) Electromagnetic TypeAir / Oil / GasNormally Closed[Rc (R)] Rc1 1/2Pilot Type40-5~50Single Solenoid220 V AC 50/60 HzNBRNoneNone-GrommetNon-locking, push type
1 Piece(s) 20 Day(s) Electromagnetic TypeAir / Oil / GasNormally Closed[Rc (R)] Rc1 1/2Pilot Type40-5~50Single Solenoid24 V DCNBRNoneNone-DIN terminalNon-locking, push type
1 Piece(s) Quote Electromagnetic TypeAir / Oil / GasNormally Closed[Rc (R)] Rc1 1/2Pilot Type40-5~50Single Solenoid24 V DCNBRNoneNone-DIN terminal with light and surge voltage suppressorNon-locking, push type
1 Piece(s) 20 Day(s) Electromagnetic TypeAir / Oil / GasNormally Closed[Rc (R)] Rc1 1/2Pilot Type40-5~50Single Solenoid24 V DCNBRNoneNone-GrommetNon-locking, push type
1 Piece(s) 20 Day(s) Electromagnetic TypeAir / Oil / GasNormally ClosedG1 1/2Pilot Type40-5~50Single Solenoid24 V DCNBRNoneCE compliant product-DIN terminalNon-locking, push type
1 Piece(s) 20 Day(s) Electromagnetic TypeAir / Oil / GasNormally ClosedNPT1 1/2Pilot Type40-5~50Single Solenoid220 V AC 50/60 HzNBRNoneNone-DIN terminalNon-locking, push type
1 Piece(s) 20 Day(s) Electromagnetic TypeOil / GasNormally Closed[Rc (R)] Rc1 1/2Pilot Type40-5~50Single Solenoid110 V AC 50/60 HzFKMNoneNone-GrommetNon-locking, push type
1 Piece(s) 31 Day(s) Electromagnetic TypeOil / GasNormally Closed[Rc (R)] Rc1 1/2Pilot Type40-5~50Single Solenoid24 V DCFKMNoneNone-DIN terminal with light and surge voltage suppressorNon-locking, push type
1 Piece(s) 20 Day(s) Electromagnetic TypeOil / GasNormally Closed[Rc (R)] Rc1 1/2Pilot Type40-5~50Single Solenoid24 V DCFKMNoneNone-GrommetNon-locking, push type
1 Piece(s) 20 Day(s) Electromagnetic TypeOil / GasNormally Closed[Rc (R)] Rc1 1/2Pilot Type40-5~50Single Solenoid24 V DCFKMNoneNone-Grommet with surge voltage suppressorNon-locking, push type
1 Piece(s) 15 Day(s) Electromagnetic TypeOilNormally ClosedG1 1/2Pilot Type40-5~50Single Solenoid-FKMNone-Not compatibleDIN terminal with light and surge voltage suppressorNon-locking, push type
1 Piece(s) 15 Day(s) Electromagnetic TypeAir / Oil / GasNormally Open[Rc (R)] Rc1 1/2Pilot Type40-5~50Single Solenoid220 V AC 50/60 HzNBRNone-Not compatibleDIN terminal with light and surge voltage suppressorNon-locking, push type
1 Piece(s) 20 Day(s) Electromagnetic TypeAir / Oil / GasNormally Open[Rc (R)] Rc1 1/2Pilot Type40-5~50Single Solenoid24 V DCNBRNoneNone-DIN terminal with light and surge voltage suppressorNon-locking, push type
1 Piece(s) 31 Day(s) Electromagnetic TypeOil / GasNormally Open[Rc (R)] Rc1 1/2Pilot Type40-5~50Single Solenoid220 V AC 50/60 HzFKMNoneNone-DIN terminal with light and surge voltage suppressorNon-locking, push type
1 Piece(s) 20 Day(s) Air Operating TypeAir / Oil / GasNormally Closed[Rc (R)] Rc2Pilot Type50-5~60--NBRNoneNone-NoneNon-locking, push type
1 Piece(s) 20 Day(s) Air Operating TypeAir / Oil / GasNormally Open[Rc (R)] Rc2Pilot Type50-5~60--NBRNoneNone-NoneNon-locking, push type
1 Piece(s) 31 Day(s) Electromagnetic TypeAir / Oil / GasNormally Closed[Rc (R)] Rc2Pilot Type50-5~50Single Solenoid110 V AC 50/60 HzNBRNoneNone-DIN terminalNon-locking, push type
1 Piece(s) 31 Day(s) Electromagnetic TypeAir / Oil / GasNormally Closed[Rc (R)] Rc2Pilot Type50-5~50Single Solenoid220 V AC 50/60 HzNBRNoneNone-DIN terminalNon-locking, push type
1 Piece(s) 31 Day(s) Electromagnetic TypeAir / Oil / GasNormally Closed[Rc (R)] Rc2Pilot Type50-5~50Single Solenoid220 V AC 50/60 HzNBRNoneNone-GrommetNon-locking, push type
1 Piece(s) 20 Day(s) Electromagnetic TypeAir / Oil / GasNormally Closed[Rc (R)] Rc2Pilot Type50-5~50Single Solenoid24 V DCNBRNoneNone-DIN terminal with light and surge voltage suppressorNon-locking, push type
1 Piece(s) 31 Day(s) Electromagnetic TypeAir / Oil / GasNormally Closed[Rc (R)] Rc2Pilot Type50-5~50Single Solenoid24 V DCNBRNoneNone-GrommetNon-locking, push type
1 Piece(s) 15 Day(s) Electromagnetic TypeAir / Oil / GasNormally ClosedG2Pilot Type50-5~50Single Solenoid220 V AC 50/60 HzNBRNone-Not compatibleDIN terminal with light and surge voltage suppressorNon-locking, push type
1 Piece(s) 20 Day(s) Electromagnetic TypeAir / Oil / GasNormally ClosedG2Pilot Type50-5~50Single Solenoid24 V DCNBRNoneCE compliant product-DIN terminal with light and surge voltage suppressorNon-locking, push type
1 Piece(s) 15 Day(s) Electromagnetic TypeAir / Oil / GasNormally ClosedG2Pilot Type50-5~50Single Solenoid-NBRNone-Not compatibleGrommetNon-locking, push type
1 Piece(s) 31 Day(s) Electromagnetic TypeAir / Oil / GasNormally Open[Rc (R)] Rc2Pilot Type50-5~50Single Solenoid100 V AC 50/60 HzNBRNoneNone-GrommetNon-locking, push type
1 Piece(s) 31 Day(s) Electromagnetic TypeAir / Oil / GasNormally Open[Rc (R)] Rc2Pilot Type50-5~50Single Solenoid24 V DCNBRNoneNone-GrommetNon-locking, push type
1 Piece(s) 15 Day(s) Electromagnetic TypeAir / Oil / GasNormally OpenG2Pilot Type50-5~50Single Solenoid220 V AC 50/60 HzNBRNone-Not compatibleDIN terminal with light and surge voltage suppressorNon-locking, push type
1 Piece(s) 15 Day(s) Electromagnetic TypeAir / Oil / GasNormally OpenNPTF2Pilot Type50-5~50Single Solenoid-NBRNone-Not compatibleDIN terminalNon-locking, push type

Loading...

Basic Information

Operating Environment Standard Body Material Aluminum Application Single Item

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:021-8990-4102 / FAX:021-8990-5803
8:30am - 5:30pm (Monday - Friday)