Circuit Protectors CP-HU Series

Circuit Protectors CP-HU Series

[CP-30HU] a combination of advanced breaker technology. Small, high performance circuit protector

PDF

Model CP30-HU Specifications

Frame A30
ModelCP30-HU
Number of Poles123
Rated current In (A)0.1 0.25 0.3 0.5 1 2 3 5
Rated
break
current
(kA)
UL 1077
CSA C22.2
No.235
Rated voltageV AC250
V DC65125-
AC2.5 kA at 250 V
10 kA at 125 V
10 kA at 250 V
DC10 kA at 65 V10 kA at 125 V-
IEC 60934
EN 60934
JIS C 4610
(Icn)
Rated insulation voltage Ui V250
AC2.5 kA at 230 V
10 kA at 120 V
10 kA at 230 V
DC10 kA at 65 V10 kA at 120 V-
IEC 60947-2
EN 60947-2
JIS C 8201-2-1 Ann.1
(Icu/Ics)
Rated insulation voltage Ui V250
AC2.5/2.5 kA at 230 V
10/10 kA at 120 V
10/10 kA at 230 V
DC10/10 kA at 60 V10/10 kA at 120 V-
Rated impulse withstand voltage Uimp (kV)2.5
AC/DC common useCommon use- (*1)
Reverse connectionPossible
Switch lifespan (times)Mechanical10,000
Electrical6,000
Standard ambient temperature (°C)40 (T40)
Operating characteristicsInstantaneous type (I); medium-speed type (M), (MD); low-speed type (S)
Tripping methodInstantaneous type (I): Electromagnetic (MO)
Medium-speed type (M), (MD); low-speed type (S): Fluid electromagnetic (HM)
Operation methodS-type (IEC 60934)
Trip-free operation methodTrip-free (IEC 60934)
External dimensions (mm)a17.53552.5
b73
c65
ca65
Product weight (kg)0.080.160.23
Accessory
devices

With inertial delay (ID)✓ Medium-speed type AC only
With alarm switch (AL)✓ (1c)
With auxiliary switch (AX)✓ (1c)
With shunt trip (SHT)✓ (Relay type only) (*2)
Parts
sold
separately
Large terminal cover (TC-L)Perfectly suitable (*5)
Embedded fittings (FP)Perfectly Suitable (*5)
Back surface wiring terminal (BT)Perfectly suitable (*3) (*5)
Jumper conductor (WB) for auxiliary circuit terminal
Suitable
Terminal cover (TC) for auxiliary terminal blockPerfectly Suitable (*5)
Terminal
shape

Main bodyWire holding screw M4
Alarm switch
auxiliary switch
Wire holding screw M3.5
Main body mounting methodFront surface mounting, IEC 35 mm rail mounting, embedded fittings mounting
Electrical Appliances and Material Safety ActCompatible
CE markingEN 60934: TÜV-certified
EN 60947-2: Self-declared (*4)

*1: Dedicated for AC use.
*2: Pole that has a shunt trip device will have no overcurrent tripping element. (Switch type shunt trip)
*3: Specify 20 A or less for the back surface wiring terminal.
*4: UL (cURus) and CE markings are displayed as standard.
*5: TUV and UL (cURus)-certified product.

ClassificationSymbol
Standard productPerfectly suitable
Semi-standard productSuitable
Made-to-orderPossible use

Classification

Notes

1: For special environments, productions of made-to-order for type 1 moisture fungus treatment, type 2 moisture fungus treatment, enhanced corrosion resistance and use in low temperatures can be made. This is not subject to UL (cURus) or CE marking.
2: Power supply and load can be connected in reverse.
3: The instantaneous type (I) may generate noise if used in an AC (sine wave) circuit and exceeds approx. 80% of the rated current, but this does not pose a performance problem. Therefore, please consider this point when using in a quiet environment.
4: Please avoid use in ambient environments with extreme temperature, humidity, dust, corrosive gas, vibration, or shock, and avoid use in circuits generating inrush current or in higher harmonic wave circuits. Unwanted operation or faults may occur.
5: Due to the automatic reset structure, the handle does not display the tripping position. However, only when an alarm switch is included, the structure will display the tripping position between ON and OFF.
6: The standard small terminal cover corresponds to IP20 from the front when the cover is closed. (TUV-certified)

Part Number
CP30-HU 1P 9-I 2A
CP30-HU 1P 9-MD 0.5A
Part NumberMinimum order quantityVolume DiscountDays to ShipRated block capacity When AC 250 V
(kA)
Rated block capacity When DC 60 V
(kA)
Rated block capacity voltage conditions besides AC 250 V/DC 60 V Number of Poles Rated Voltage Rated Current
(A)
Operating properties Warning output presence Representative Standard Dimension width
(mm)
Inertial delay included P1 internal circuit specification P2 internal circuit specification P3 internal circuit specification Rated block capacity when DC 120 V
(kA)
Rated block capacity when AC 230 V
(kA)
Rated block capacity when AC 120 V
(kA)
Rated block capacity When DC 125 V
(kA)
1 Piece(s) Quote 2.5kA10kAAvailable1-poleAC250V / DC65V2InstantaneousAvailablePSE / CE / UL / TUV / CSA17.5×Serial type / Warning switch / for general load---2.510-
1 Piece(s) Quote 2.5kA10kAAvailable1-poleAC250V / DC65V0.5Medium speedAvailablePSE / CE / UL / TUV / CSA17.5Serial type / Warning switch / for general load---2.510-

Loading...

  1. 1
 

Basic Information

Polarity presence NA Dimension height(mm) 73 Dimension depth(mm) 65
Connection Method Screw

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:021-8990-4102 / FAX:021-8990-5803
8:30am - 5:30pm (Monday - Friday)