(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Sehubungan dengan adanya Peraturan Baru Kementerian Perdagangan No.36 Tahun 2023 tentang Pembatasan Impor Barang, MISUMI Indonesia melakukan tindakan pencegahan. Lihat informasi detailnya di sini
    Due to New Regulation of Ministry Of Trade No.36 of 2023 concerning retrictions on imports of goods, MISUMI Indonesia do precautions measure. See detail information here
  • Nomor telepon alternatif Kontak Layanan Pelanggan : 021-29182911| 021-29182991 | 021-29182997 | 021-29182998
    Alternative telephone number Contact Customer Service: 021-29182911 | 021-29182991 | 021-29182997 | 021-29182998

Super Timer MS4S Series

Super Timer MS4S Series

[Features]
· A short barrel size of 66.5 mm from the neck down: Multi-mode, ON delay, Instantaneously connected ON delay, OFF delay, star delta, repeat operation type all implemented in a short barrel size of 66.5 mm from the neck down.
· Direct reading timed graduation not requiring conversion to hexadecimal notation is adopted: by using a direct reading timed hexadecimal scale of 30 seconds (minutes) and 60 seconds (minute), it can be set easily (time specification from 0.05 seconds to 60 hours is supported by 1 unit) even without converting the time limit setting such as 56 minutes, 27 minutes to hexadecimal.
· Improved measures in respect of the wave distortion in the power source: Improved resistance to power source wave distortion by use of an inverter and the like.
· An AC free power source: AC100 to 240V sharing of the power source voltage achieved.
· Zero scale instantaneous operation function: When the time period setting is done using a zero scale, because instantaneous output is enabled, sequence checking is simplified.

Part Number

Configured Part Number is shown.

Part Number
MS4SA-AP
MS4SA-CE
MS4SA-DL
MS4SC-AP
MS4SC-CE
MS4SC-DL
MS4SF-AP1N
MS4SF-AP1NR
MS4SF-AP1T
MS4SF-AP1TR
MS4SF-CE1N
MS4SF-CE1NR
MS4SF-CE1T
MS4SF-CE1TR
MS4SF-DL1N
MS4SF-DL1NR
MS4SF-DL1T
MS4SF-DL1TR
MS4SM-AP
MS4SM-CE
MS4SM-DL
MS4SR-AP
MS4SR-APN
MS4SY-AP
Part NumberMinimum order quantityVolume DiscountDays to ShipRoHSPower Supply Voltage Representative Standard Dimension depth
(mm)
Operating Mode Rated control power supply voltage
(V)
Rated time limit Contact Configuration Types of operation Specifications Time specifications
1 Piece(s) Quote -AC-dedicatedCE / UL / TUV / CSA81.5ON delay — operationAC100-240V--OFF StartTime Limit 2c16-range switching from 0.6 s – 60 h
1 Piece(s) Quote -AC/DCCE / UL / TUV / CSA81.5ON delay — operationAC/DC24V--OFF StartTime Limit 2c16-range switching from 0.6 s – 60 h
1 Piece(s) 14 Day(s) 10Dedicated to DCCE / UL / TUV / CSA81.5ON delay — operationDC48-127V--OFF StartTime Limit 2c16-range switching from 0.6 s – 60 h
1 Piece(s) Quote -AC-dedicatedCE / UL / TUV / CSA81.5ON delay — operationAC100-240V--OFF StartTime limit 1c + instant 1c16-range switching from 0.6 s – 60 h
1 Piece(s) Quote -AC/DCCE / UL / TUV / CSA81.5ON delay — operationAC/DC24V--OFF StartTime limit 1c + instant 1c16-range switching from 0.6 s – 60 h
1 Piece(s) 88 Day(s) 10Dedicated to DCCE / UL / TUV / CSA81.5ON delay — operationDC48-127V--OFF StartTime limit 1c + instant 1c16-range switching from 0.6 s – 60 h
1 Piece(s) 88 Day(s) 10AC-dedicatedCE / UL / CSA81.5OFF delay — operationAC100-240V0.6–12 min-OFF StartTime Limit 2cFour range switching for minute-unit products: 0.6–12 min
1 Piece(s) 88 Day(s) 10AC-dedicatedCE / UL / CSA81.5OFF delay — operationAC100-240V0.6–12 minIncludes resetOFF StartIncludes time limit 1c + instant resetFour range switching for minute-unit products: 0.6–12 min
1 Piece(s) 14 Day(s) 10AC-dedicatedCE / UL / CSA81.5OFF delay — operationAC100-240V0.6 to 12s-OFF StartTime Limit 2cFour range switching for second-unit products: 0.6–12 s
1 Piece(s) 88 Day(s) 10AC-dedicatedCE / UL / CSA81.5OFF delay — operationAC100-240V0.6 to 12sIncludes resetOFF StartIncludes time limit 1c + instant resetFour range switching for second-unit products: 0.6–12 s
1 Piece(s) 88 Day(s) 10AC/DCCE / UL / CSA81.5OFF delay — operationAC/DC24V0.6–12 min-OFF StartTime Limit 2cFour range switching for minute-unit products: 0.6–12 min
1 Piece(s) 88 Day(s) 10AC/DCCE / UL / CSA81.5OFF delay — operationAC/DC24V0.6–12 minIncludes resetOFF StartIncludes time limit 1c + instant resetFour range switching for minute-unit products: 0.6–12 min
1 Piece(s) 14 Day(s) 10AC/DCCE / UL / CSA81.5OFF delay — operationAC/DC24V0.6 to 12s-OFF StartTime Limit 2cFour range switching for second-unit products: 0.6–12 s
1 Piece(s) 88 Day(s) 10AC/DCCE / UL / CSA81.5OFF delay — operationAC/DC24V0.6 to 12sIncludes resetOFF StartIncludes time limit 1c + instant resetFour range switching for second-unit products: 0.6–12 s
1 Piece(s) 88 Day(s) 10Dedicated to DCCE / UL / CSA81.5OFF delay — operationDC48-127V0.6–12 min-OFF StartTime Limit 2cFour range switching for minute-unit products: 0.6–12 min
1 Piece(s) 88 Day(s) 10Dedicated to DCCE / UL / CSA81.5OFF delay — operationDC48-127V0.6–12 minIncludes resetOFF StartIncludes time limit 1c + instant resetFour range switching for minute-unit products: 0.6–12 min
1 Piece(s) 88 Day(s) 10Dedicated to DCCE / UL / CSA81.5OFF delay — operationDC48-127V0.6 to 12s-OFF StartTime Limit 2cFour range switching for second-unit products: 0.6–12 s
1 Piece(s) 88 Day(s) 10Dedicated to DCCE / UL / CSA81.5OFF delay — operationDC48-127V0.6 to 12sIncludes resetOFF StartIncludes time limit 1c + instant resetFour range switching for second-unit products: 0.6–12 s
1 Piece(s) Quote -AC-dedicatedCE / UL / TUV / CSA81.5ON delay, flicker, one-shot, signal OFF delay — operationAC100-240V--OFF StartTime Limit 2c16-range switching from 0.6 s – 60 h
1 Piece(s) Quote -AC/DCCE / UL / TUV / CSA81.5ON delay, flicker, one-shot, signal OFF delay — operationAC/DC24V--OFF StartTime Limit 2c16-range switching from 0.6 s – 60 h
1 Piece(s) 88 Day(s) 10Dedicated to DCCE / UL / TUV / CSA81.5ON delay, flicker, one-shot, signal OFF delay — operationDC48-127V--OFF StartTime Limit 2c16-range switching from 0.6 s – 60 h
1 Piece(s) Quote -AC-dedicatedCE / UL / CSA83RepeatAC100-240V--OFF StartTime Limit 2c16-range switching from 0.6 s – 60 h
1 Piece(s) 14 Day(s) -AC-dedicatedCE / UL / CSA83RepeatAC100-240V--ON StartTime Limit 2c16-range switching from 0.6 s – 60 h
1 Piece(s) Quote -AC-dedicatedCE / UL / CSA81.5Star/DeltaAC100-240V--OFF StartTime limit 1a (Start output) 1a (Delta output) + instant 1a4-range switching from 6 sec to 120 sec

Loading...

  1. 1

Basic Information

Type Timer Display method Analog Dimension vertical(mm) 48
Dimension width(mm) 48 Connection Method Plug-In

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:021-8990-4102 / FAX:021-8990-5803
8:30am - 5:30pm (Monday - Friday)