Overload Relays TH-T Series

Overload  Relays TH-T Series

Mitsubishi thermal relay TH-T series.
[Features]
・ ncredible performance housed in a small body.
・ The even more advanced version of the Mitsubishi Electric electromagnetic opening/closing device.
・ Can be used to detect motor overload and locked rotor current.
・ Product lineup containing overload short circuit protection, time lag and accelerated types for every application.
[Applications]
・ Motor burnout protection.

PDF

TH-T Series Features

Applicable to motor protection: can be used for standard motor overload and locking protection.
Easy current value setting: can directly set the motor current value. Adjust with a cross-head / straight-slot screwdriver.
Reset method change: easy to change between manual reset and automatic reset.
With 1a1b contact: can use different voltages for a and b contacts.
Terminal cover as standard equipment (TH-T18/TH-T50): Having a terminal cover as standard equipment reduces the time for customers to specify a separate model name or arrange for options. This reduces inventory and reduces cover costs. Safety has also improved for protecting the live parts.

TH-T18 Outline Drawing / Contact Configuration

TH-T series thermal relay: related image

Outline drawing

TH-T series thermal relay: related image

Contact Configuration

For combining with the following electromagnetic contactors.
TH-T18:S-T10, T12, T20 SD-T12, T20
Can use as single unit in combination with single unit mounting unit UT-HZ18.

TH-T50 Outline Drawing / Contact Configuration

TH-T series thermal relay: related image

Outline drawing

TH-T series thermal relay: related image

Contact Configuration

Cannot be used with single unit mounting.
Use the following connection conductor (sold separately) when combining with an electromagnetic contactor.
Combination with S-T35/T50 (BC), SD-T35/T50 (BC): UT-TH50

TH-T65 Outline Drawing / Contact Configuration

TH-T series thermal relay: related image

Outline drawing

TH-T series thermal relay: related image

Contact Configuration

Use the following connection conductor kit (sold separately) when combining with an electromagnetic contactor.
Combination with S (D) -T65/T80: BH559N350
Combination with S-T100: BH569N350
Combination with SD-T100: BH569N352

TH-T100 Outline Drawing / Contact Configuration

TH-T series thermal relay: related image

Outline drawing

TH-T series thermal relay: related image

Contact Configuration

Cannot be used with single unit mounting.
Use the following connection conductor kit (sold separately) when combining with an electromagnetic contactor.
Connection conductor kit (sold separately, model name: BH569N350) used
Combination with S (D) -T80: BH559N350
Combination with S-T100: BH569N350
Combination with SD-T100: BH569N352

Part Number
TH-T18KP 0.7A
TH-T18KP 0.9A
TH-T18KP 0.12A
TH-T18KP 0.17A
TH-T18KP 1.3A
TH-T18KP 1.7A
TH-T18KP 2.1A
TH-T18KP 2.5A
TH-T18KP 3.6A
TH-T18KP 9A
TH-T18KP 11A
TH-T18KP 15A
TH-T50 35A
TH-T100 95A
Part NumberMinimum order quantityVolume DiscountDays to ShipMotor capacity/nominal thermal nominal size 440 VAC
(kW/A)
Motor Capacity / Thermal Nominal Size VAC 220
(kW/A)
Coil rated voltage
(V)
Auxiliary Contact Representative Standard Dimension length
(mm)
Dimension width
(mm)
Dimension thickness
(mm)
Specifications Frame Size Finger protection/terminal cover Nominal heater size
(A)
Nominal heater size
(A)
Settling current adjustment range
(A)
Rated insulation voltage
(V)
Rate Impulse voltage resistant
(kV)
Rated current used level AC-15 (opening/closing AC electromagnetic contactor coil) a contact/b contact AC 24 V
(A)
Rated current used level AC-15 (opening/closing AC electromagnetic contactor coil) a contact/b contact AC 120 V
(A)
Rated current used level AC-15 (opening/closing AC electromagnetic contactor coil) a contact/b contact AC 240 V
(A)
Rated current used level AC-15 (opening/closing AC electromagnetic contactor coil) a contact/b contact AC 550 V
(A)
Rated current used level DC-13 (opening/closing direct current electromagnetic contactor coil) DC 24 V
(A)
Rated current used level DC-13 (opening/closing direct current electromagnetic contactor coil) DC 110 V
(A)
Rated current used level DC-13 (opening/closing direct current electromagnetic contactor coil) DC 220 V
(A)
Application Terminal screw size (main circuit/operating circuit) Trip class Trip free Reset method Operation display (lever display) Manual trip check
1 Piece(s) 5 Day(s) 0.10.18690-CE / CUL / TUV / CCC554676.5----------------------
1 Piece(s) 5 Day(s) -0.25690-CE / CUL / TUV / CCC554676.5----------------------
1 Piece(s) 5 Day(s) --690-CE / CUL / TUV / CCC554676.5----------------------
1 Piece(s) 5 Day(s) --690-CE / CUL / TUV / CCC554676.5----------------------
1 Piece(s) 5 Day(s) 0.2-690-CE / CUL / TUV / CCC554676.5----------------------
1 Piece(s) 5 Day(s) -0.75690-CE / CUL / TUV / CCC554676.5----------------------
1 Piece(s) Same day 0.4-690-CE / CUL / TUV / CCC554676.5----------------------
1 Piece(s) 5 Day(s) -1.1690-CE / CUL / TUV / CCC554676.5----------------------
1 Piece(s) 5 Day(s) 0.751.5690-CE / CUL / TUV / CCC554676.5----------------------
1 Piece(s) 5 Day(s) 2.23690-CE / CUL / TUV / CCC554676.5----------------------
1 Piece(s) 5 Day(s) -5.5690-CE / CUL / TUV / CCC554676.5----------------------
1 Piece(s) 5 Day(s) 3.77.5690-CE / CUL / TUV / CCC554676.5----------------------
1 Piece(s) 5 Day(s) -18.5690-CE / CUL / TUV / CCC74.37488----------------------
1 Piece(s) 5 Day(s) 2245690-CE / CUL / TUV / CCC8968.583.5----------------------