Control/Instrumentation Cables(Rated Voltage:300V)

Control and instrumentation cables are used for device controls and signal transmissions to and from terminal devices. Control cables are mainly used to control devices in plants and factories. For this reason, insulated vinyl sheath cables with PVC and polyethylene insulation are usually used for their highly flame retardant properties and excellent oil resistance, weather resistance and water resistance. Instrumentation cables are used in a wide range of applications including transmitting computer signals, electronic controls for industrial equipment, etc. Insulated vinyl sheath cables with polyethylene insulators are often used for their capacitance and noise reduction characteristics. The cables are selected for length and number of pairs, but other specific properties should also be considered, such as abrasion resistance and chemical resistance.
Days to Ship
  • All
  • 11 Day(s) or Less
  • 12 Day(s) or Less
  • 15 Day(s) or Less
  • 16 Day(s) or Less
  • 18 Day(s) or Less
  • 19 Day(s) or Less
  • 20 Day(s) or Less
  1. 1
Brand
Product Series
Days to Ship
Overall Length(m)
Specified Length(m)
Conductor Cross Section(mm2)
AWG size(AWG)
Number Of Cores(Core)
Logarithm
Finished outer diameter(mm)
Rated Voltage
Shield
Properties
Representative Standard
Sheath (outer coating) color
Grounding Wire
Sheath (outer coating) material
Insulation body materials

    UL Listed Unshielded Instrumentation Cable

      VVC Highly Flame-Retardant NEC Standard Cable (Shielded)

        BIOS Highly Flame Retardant NEC Standard Cable (Shielded)

          Thick Multi-Pair Cable

            VVC Highly Flame-Retardant NEC Standard Cable (Unshielded)

              BIO Highly Flame Retardant NEC Standard Cable (Non-Shield)

              Brand

              TACHII ELECTRIC WIRE

              BANDO DENSEN

              BANDO DENSEN

              HITACHI CABLE

              BANDO DENSEN

              BANDO DENSEN

              Product Series

              UL Listed Unshielded Instrumentation Cable

              VVC Highly Flame-Retardant NEC Standard Cable (Shielded)

              BIOS Highly Flame Retardant NEC Standard Cable (Shielded)

              Thick Multi-Pair Cable

              VVC Highly Flame-Retardant NEC Standard Cable (Unshielded)

              BIO Highly Flame Retardant NEC Standard Cable (Non-Shield)

              Days to Ship 16 Day(s) or more 16 Day(s) or more 16 Day(s) or more 16 Day(s) or more 16 Day(s) or more 16 Day(s) or more
              Overall Length(m)1 ~ 1001 ~ 1001 ~ 1001 ~ 2001 ~ 1001 ~ 100
              Specified Length(m)------
              Conductor Cross Section(mm2)0.22 ~ 0.54--0.12 ~ 0.2--
              AWG size(AWG)20 ~ 2420 ~ 2416 ~ 2624 ~ 2620 ~ 2416 ~ 26
              Number Of Cores(Core)2 ~ 502 ~ 402 ~ 1010 ~ 502 ~ 142 ~ 10
              Logarithm1P ~ 25P-1P ~ 25P5P ~ 25P-1P ~ 20P
              Finished outer diameter(mm)4 ~ 155.5 ~ 13.74.7 ~ 18.3-4.9 ~ 8.94.1 ~ 17.6
              Rated Voltage300V300V300V300V300V300V
              ShieldNAAvailableAvailableAvailableNANA
              PropertiesOil Resistance / Heat-ResistanceHeat-ResistanceOil Resistance / Heat-ResistanceHeat-ResistanceHeat-ResistanceOil Resistance / Heat-Resistance
              Representative StandardUL / CSA(c-UL)ULUL / CSA(c-UL)ULULUL / CSA(c-UL)
              Sheath (outer coating) colorBlackGrayBlackGrayGrayBlack
              Grounding WireNA-----
              Sheath (outer coating) materialPVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)
              Insulation body materialsPVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)

              Loading...