Control/Instrumentation Cables(Representative Standard:CSA(c-UL))

Control and instrumentation cables are used for device controls and signal transmissions to and from terminal devices. Control cables are mainly used to control devices in plants and factories. For this reason, insulated vinyl sheath cables with PVC and polyethylene insulation are usually used for their highly flame retardant properties and excellent oil resistance, weather resistance and water resistance. Instrumentation cables are used in a wide range of applications including transmitting computer signals, electronic controls for industrial equipment, etc. Insulated vinyl sheath cables with polyethylene insulators are often used for their capacitance and noise reduction characteristics. The cables are selected for length and number of pairs, but other specific properties should also be considered, such as abrasion resistance and chemical resistance.
Days to Ship
  • All
  • 11 Day(s) or Less
  • 12 Day(s) or Less
  • 15 Day(s) or Less
  • 16 Day(s) or Less
  • 18 Day(s) or Less
  • 19 Day(s) or Less
  • 20 Day(s) or Less
  1. 1
Brand
Product Series
Days to Ship
Overall Length(m)
Specified Length(m)
Conductor Cross Section(mm2)
AWG size(AWG)
Number Of Cores(Core)
Logarithm
Finished outer diameter(mm)
Rated Voltage
Shield
Properties
Representative Standard
Sheath (outer coating) color
Grounding Wire
Sheath (outer coating) material
Insulation body materials

    Twisted Pair Instrumentation Cable

      KVC-36SBT

        UL Listed Unshielded Instrumentation Cable

          CL2/2464-3599-DS LF

            Twisted Layer Instrumentation Cable

              BIOS Highly Flame Retardant NEC Standard Cable (Shielded)

                BIO Highly Flame Retardant NEC Standard Cable (Non-Shield)

                Brand

                TACHII ELECTRIC WIRE

                KURAMO ELECTRIC

                TACHII ELECTRIC WIRE

                TAIYO CABLETEC

                TACHII ELECTRIC WIRE

                BANDO DENSEN

                BANDO DENSEN

                Product Series

                Twisted Pair Instrumentation Cable

                KVC-36SBT

                UL Listed Unshielded Instrumentation Cable

                CL2/2464-3599-DS LF

                Twisted Layer Instrumentation Cable

                BIOS Highly Flame Retardant NEC Standard Cable (Shielded)

                BIO Highly Flame Retardant NEC Standard Cable (Non-Shield)

                Days to Ship 16 Day(s) or more 11 Day(s) or more 16 Day(s) or more 11 Day(s) or more 16 Day(s) or more 16 Day(s) or more 16 Day(s) or more
                Overall Length(m)1 ~ 1001 ~ 1001 ~ 1001 ~ 1001 ~ 1001 ~ 1001 ~ 100
                Specified Length(m)-------
                Conductor Cross Section(mm2)0.2 ~ 0.50.50.22 ~ 0.540.204 ~ 0.8230.2 ~ 0.3--
                AWG size(AWG)20 ~ 242020 ~ 2418 ~ 2422 ~ 2416 ~ 2616 ~ 26
                Number Of Cores(Core)2 ~ 502 ~ 402 ~ 50-2 ~ 402 ~ 102 ~ 10
                Logarithm1P ~ 25P1P ~ 20P1P ~ 25P1P ~ 5P-1P ~ 25P1P ~ 20P
                Finished outer diameter(mm)4.6 ~ 15.94.8 ~ 164 ~ 155.1 ~ 144.6 ~ 11.64.7 ~ 18.34.1 ~ 17.6
                Rated VoltageOtherFor Low Current Circuits300VFor Low Current CircuitsOther300V300V
                ShieldAvailableAvailableNAAvailableAvailableAvailableNA
                PropertiesOil Resistance / Heat-ResistanceOil ResistanceOil Resistance / Heat-ResistanceOil Resistance / Heat-ResistanceOil Resistance / Heat-ResistanceOil Resistance / Heat-ResistanceOil Resistance / Heat-Resistance
                Representative StandardCSA(c-UL)CSA(c-UL)CSA(c-UL)CSA(c-UL)CSA(c-UL)CSA(c-UL)CSA(c-UL)
                Sheath (outer coating) colorGrayBlackBlackBlackBlackBlackBlack
                Grounding WireOtherOtherNANAOther--
                Sheath (outer coating) materialPVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)
                Insulation body materialsPVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)Polyethylene-BasedPVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)