(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Sehubungan dengan adanya Peraturan Baru Kementerian Perdagangan No.36 Tahun 2023 tentang Pembatasan Impor Barang, MISUMI Indonesia melakukan tindakan pencegahan. Lihat informasi detailnya di sini
    Due to New Regulation of Ministry Of Trade No.36 of 2023 concerning retrictions on imports of goods, MISUMI Indonesia do precautions measure. See detail information here
  • Nomor telepon alternatif Kontak Layanan Pelanggan : 021-29182911| 021-29182991 | 021-29182997 | 021-29182998
    Alternative telephone number Contact Customer Service: 021-29182911 | 021-29182991 | 021-29182997 | 021-29182998

Control/Instrumentation Cables(Representative Standard:CSA(c-UL))

Control and instrumentation cables are used for device controls and signal transmissions to and from terminal devices. Control cables are mainly used to control devices in plants and factories. For this reason, insulated vinyl sheath cables with PVC and polyethylene insulation are usually used for their highly flame retardant properties and excellent oil resistance, weather resistance and water resistance. Instrumentation cables are used in a wide range of applications including transmitting computer signals, electronic controls for industrial equipment, etc. Insulated vinyl sheath cables with polyethylene insulators are often used for their capacitance and noise reduction characteristics. The cables are selected for length and number of pairs, but other specific properties should also be considered, such as abrasion resistance and chemical resistance.
Days to Ship
  • All
  • 10 Day(s) or Less
  • 11 Day(s) or Less
  • 12 Day(s) or Less
  • 14 Day(s) or Less
  • 15 Day(s) or Less
  • 16 Day(s) or Less
  • 18 Day(s) or Less
  • 19 Day(s) or Less
  • 20 Day(s) or Less
  1. 1
Brand
Product Series
Days to Ship
Overall Length(m)
Specified Length(m)
Conductor Cross Section(mm2)
AWG size(AWG)
Number Of Cores(Core)
Logarithm
Finished outer diameter(mm)
Rated Voltage
Shield
Properties
Representative Standard
Sheath (outer coating) color
Grounding Wire
Sheath (outer coating) material
Insulation body materials

    UL Listed Unshielded Instrumentation Cable

      KVC-36SBT

        BIO Highly Flame Retardant NEC Standard Cable (Non-Shield)

          Twisted Layer Instrumentation Cable

            Twisted Pair Instrumentation Cable

              BIOS Highly Flame Retardant NEC Standard Cable (Shielded)

                CL2/2464-3599-DS LF

                Brand

                TACHII ELECTRIC WIRE

                KURAMO ELECTRIC

                BANDO DENSEN

                TACHII ELECTRIC WIRE

                TACHII ELECTRIC WIRE

                BANDO DENSEN

                TAIYO CABLETEC

                Product Series

                UL Listed Unshielded Instrumentation Cable

                KVC-36SBT

                BIO Highly Flame Retardant NEC Standard Cable (Non-Shield)

                Twisted Layer Instrumentation Cable

                Twisted Pair Instrumentation Cable

                BIOS Highly Flame Retardant NEC Standard Cable (Shielded)

                CL2/2464-3599-DS LF

                Days to Ship 16 Day(s) or more 10 Day(s) or more 16 Day(s) or more 16 Day(s) or more 16 Day(s) or more 16 Day(s) or more 10 Day(s) or more
                Overall Length(m)1 ~ 1001 ~ 1001 ~ 1001 ~ 1001 ~ 1001 ~ 1001 ~ 100
                Specified Length(m)-------
                Conductor Cross Section(mm2)0.22 ~ 0.540.5-0.2 ~ 0.30.2 ~ 0.5-0.204 ~ 0.823
                AWG size(AWG)20 ~ 242016 ~ 2622 ~ 2420 ~ 2416 ~ 2618 ~ 24
                Number Of Cores(Core)2 ~ 502 ~ 402 ~ 102 ~ 402 ~ 502 ~ 10-
                Logarithm1P ~ 25P1P ~ 20P1P ~ 20P-1P ~ 25P1P ~ 25P1P ~ 5P
                Finished outer diameter(mm)4 ~ 154.8 ~ 164.1 ~ 17.64.6 ~ 11.64.6 ~ 15.94.7 ~ 18.35.1 ~ 14
                Rated Voltage300VFor Low Current Circuits300VOtherOther300VFor Low Current Circuits
                ShieldNAAvailableNAAvailableAvailableAvailableAvailable
                PropertiesOil Resistance / Heat-ResistanceOil ResistanceOil Resistance / Heat-ResistanceOil Resistance / Heat-ResistanceOil Resistance / Heat-ResistanceOil Resistance / Heat-ResistanceOil Resistance / Heat-Resistance
                Representative StandardCSA(c-UL)CSA(c-UL)CSA(c-UL)CSA(c-UL)CSA(c-UL)CSA(c-UL)CSA(c-UL)
                Sheath (outer coating) colorBlackBlackBlackBlackGrayBlackBlack
                Grounding WireNAOther-OtherOther-NA
                Sheath (outer coating) materialPVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)
                Insulation body materialsPVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)Polyethylene-Based

                Loading...