(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Sehubungan dengan adanya Peraturan Baru Kementerian Perdagangan No.36 Tahun 2023 tentang Pembatasan Impor Barang, MISUMI Indonesia melakukan tindakan pencegahan. Lihat informasi detailnya di sini
    Due to New Regulation of Ministry Of Trade No.36 of 2023 concerning retrictions on imports of goods, MISUMI Indonesia do precautions measure. See detail information here
  • Nomor telepon alternatif Kontak Layanan Pelanggan : 021-29182911| 021-29182991 | 021-29182997 | 021-29182998
    Alternative telephone number Contact Customer Service: 021-29182911 | 021-29182991 | 021-29182997 | 021-29182998

Throttle Valve PP Type Union Straight for Clean Environment

Throttle Valve PP Type Union Straight for Clean Environment

[Features]
·PP resin is used for the main body, making it suitable for use in clean environments.
·SUS304 is used for the metal parts.
·EPDM is used for the seal.
· Oil-free specification.
·Because the color of the resin body is clear (semi-transparent), fluid (liquid) can be checked.
·The union type has been renewed to compact union type.
·It features a more compact structure and a 15% cut in price.
* Currently, the digital book shows the "PJNU" series before the part number change, and will be updated at a later date.

(i)Caution

  • Some of the items are scheduled to be discontinued as of end of March in 2023. The manufacturer keep the items produced but they are not available with Misumi.
    There are not the replacement items and the plan to resumption of sale. Please check the quotation and order screen for details.

PDF

Japanese Only

Drawing

Drawing of Throttle Valve, PP Type, for Clean Environments, Union Straight

Product Specifications

Product Specifications

Operating fluidAir, water (see condition *1), other (see condition *1)
Maximum operating pressure1.0 MPa (at 0 to +20°C) *2
Operating vacuum pressure-100 kPa
Operating temperature range0 to +80°C (no freezing)
  • *1. When using this product with water or other chemicals, be sure to observe the following conditions.
    1. When using this product with water or other liquid, ensure that the surge pressure will not exceed the maximum operating pressure.
    2. When using water or other liquid, be sure to use the insert ring.
    3. Regarding chemicals, mixed gas, etc., the conformity of the manufacturer's specifications may differ depending on the usage conditions, so please check before use.
  • *2. For the maximum operating pressure when the operating temperature exceeds 20°C, refer to "Relationship graph between operating temperature and maximum operating pressure."

Standard table

ModelTube
Outer Diameter
⌀D
B1B2⌀PTTube
End
C
ødF1F2Weight
(g)
max.min.
PJNMU6 (4)(6)625.421.624.612.513.117.13.214.86.213
PJNMU8 (4)(6)830.625.12814.815.418.13.218.27.225
PJNMU10 (4)(6)1035.428.93218.219.720.44.222.28.745
PJNMU12 (4)(6)123831.537.121.222.723.64.225.710.262
  • *1. Please enter the symbol: "-F" (FKM) and the symbol: "-HN" (HNBR) in (4) of a model only when a seal rubber material should be changed.
  • *2. Please enter the symbol: "-C" in □ at the end of a model when the cleanroom packaging specification is required.

Usage examples

Speed ​​adjustment method

1. Speed adjustment of drive equipment

Related image 1 of Throttle Valve, PP Type, for Clean Environments, Union Straight

(1) When increasing the speed
The flow rate increases as the needle of the throttle valve PP is turned counterclockwise from the fully closed state. When the flow rate reaches the desired value, be sure to tighten the lock nut to prevent the flow rate setting from deviating.

Related image 2 of Throttle Valve, PP Type, for Clean Environments, Union Straight

(2) When slowing down
If the needle of the throttle valve PP is turned too much (i.e. if the flow rate becomes too high), turn it clockwise to decrease the flow rate. When the flow rate reaches the desired value, be sure to tighten the lock nut to prevent the flow rate setting from deviating.

How To Attach And Detach The Connecting Part

1. How to attach/detach the tube

Related image 3 of Throttle Valve, PP Type, for Clean Environments, Union Straight

(1) Installation of tube

By simply inserting a tube until the tube stop, the Throttle Valve PP (Needle Throttle Valve With Quick-Connect Fitting for Clean Environment) fixes it with its lock claws, and the elastic sleeve seals the outer circumference of the tube.
When installing, refer to the precautions "6. Precautions for installing the tube" in the digital catalog.

Related image 4 of Throttle Valve, PP Type, for Clean Environments, Union Straight

(2) Removing the tube

When removing the tube, the lock claw opens by pushing the release ring, and the tube can be pulled out.
Please be sure to turn off the air before removing.

2. Screw tightening method

Related image 5 of Throttle Valve, PP Type, for Clean Environments, Union Straight

(1) Tightening the screws

To tighten the screws, use a spanner to tighten the hexagonal outer diameter.
When tightening, please refer to the table of Common Control Precautions "2. Precautions for mounting the main unit" and tighten the torque.

Cautions/prohibitions

Warning

1. Selection of pneumatic equipment

(1) The selection of pneumatic equipment should be decided by a person who has sufficient knowledge and experience, such as a pneumatic system designer or a person who decides specifications.

(2) Since the conditions used are diverse, before determining the compatibility with a system, ensure that a person with sufficient knowledge and experience, such as a pneumatic system designer or a person who decides the specifications, perform analyses and tests as necessary. In addition, it is the responsibility of the person who determines the compatibility with the system to guarantee the intended performance and safety of the system. Also after that, please review all the details of the specifications on the latest product catalogs and documents, and consider the situation regarding the possibility of equipment failure before configure a system.

2. A person with sufficient knowledge and experience should handle the pneumatic equipment.

(1) Compressed air is dangerous if mishandled. Ensure that a person with sufficient knowledge and experience performs assembly, operation, maintenance, etc., of machines and devices using pneumatic equipment.

3. Please do not handle machines/devices or remove devices until safety is confirmed.

(1) Before inspecting or servicing machines/devices, make sure that workpiece fall prevention measures are taken and runaway prevention devices are installed.

(2) When removing equipment, make sure that the above safety measures are taken, shut off the supply of compressed air and the power supply of the corresponding equipment, and exhaust the compressed air from the system.

(3) When restarting a machine/device, make sure that measures are taken to prevent popping out and be careful.

  • * Please note that cautions and prohibited items are subject to change without notice.
Part Number
PJNMU6
PJNMU8
PJNMU10
PJNMU12
Part NumberMinimum order quantityVolume DiscountDays to ShipRoHSOperating Temp. Range
(°C)
Operating Pressure Range
(MPa)
Nominal Diameter of Tube D Trusco Code
1 Piece(s) 12 Day(s) 100~800~0.96-
1 Piece(s) Same day 100~800~0.98-
1 Piece(s) 23 Day(s) or more -0~ 80-10778-1351
1 Piece(s) 16 Day(s) or more -0~800~0.912-

Loading...

  1. 1

Basic Information

Type Throttle Valves Shape Union Straight Control Direction Meter Out / In
Joint Type Tube, Tube Connection Material PP Environment, Applications Clean circumstance
Thread Material SUS304 Knob Type Standard Lock Nut Type Knurling
Package Specifications Regular Packaging Specifications Seal Rubber Material EPDM Applicable Fluids Air/Oxygen/Inert gas/Water/Chemicals/Mixed gas

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:021-8990-4102 / FAX:021-8990-5803
8:30am - 5:30pm (Monday - Friday)