(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Pembayaran dengan kartu kredit untuk sementara tidak tersedia karena kendala sistem. Sementara waktu Anda dapat meggunakan metode Pembayaran di Muka atau QRIS. Untuk informasi lebih lanjut, silakan hubungi Customer Service : TEL: 021-8984-0008 E-mail: cs@misumi.co.id. WA: 08118984008. Kami mohon maaf atas ketidaknyamanan yang terjadi.
    Credit card payments are temporarily unavailable due to system issues. Meanwhile, you can use the Advance Payment method or QRIS. For further information, please contact Customer Service: TEL: 021-8984-0008 E-mail: cs@misumi.co.id. WA: 08118984008. We apologize for any inconvenience caused.
  • Pemberitahuan Jadwal Pemeliharaan : Situs ini akan tidak tersedia dikarenaka jadwal pemeliharaan mulai dari 8:00 21/4/2024 sampai dengan 5:00 pada tanggal 22/4/2024. Kami mohon maaf atas ketidaknyamanan yang terjadi.
    Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 8:00 21/4/2024 to 5:00 (WIB) 22/4/2024. We apologize for the inconvenience.
  • Sehubungan dengan adanya Peraturan Baru Kementerian Perdagangan No.36 Tahun 2023 tentang Pembatasan Impor Barang, MISUMI Indonesia melakukan tindakan pencegahan. Lihat informasi detailnya di sini
    Due to New Regulation of Ministry Of Trade No.36 of 2023 concerning retrictions on imports of goods, MISUMI Indonesia do precautions measure. See detail information here

Direct Operated 3-Port Solenoid Valve Single General-Purpose Valve AG31/41 Series

Direct Operated 3-Port Solenoid Valve Single General-Purpose Valve AG31/41 Series

Multilex valve series for controlling various fluids including water, air, oil, and vacuum. Offers high reliability and high quality and the ample options assure performance in different equipment and device types.

(i)Caution

  • Some of the items are scheduled to be discontinued as of end of March in 2023. The manufacturer keep the items produced but they are not available with Misumi.
    There are not the replacement items and the plan to resumption of sale. Please check the quotation and order screen for details.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

Part Number
AG41-02-1-0-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-1-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-1-B-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-1-C-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-1-D-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-1-E-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-1-F-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-1-H-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-1-HZ-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-1-J-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-1-JZ-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-1-K-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-1-L-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-1-LZ-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-1-M-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-1-MZ-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-1-N-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-1-P-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-1-PZ-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-1-R-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-1-RZ-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-1-V-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-1-W-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-2-0-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-2-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-2-B-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-2-C-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-2-D-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-2-E-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-2-F-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-2-H-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-2-HZ-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-2-J-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-2-JZ-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-2-K-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-2-L-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-2-LZ-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-2-M-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-2-MZ-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-2-N-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-2-P-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-2-PZ-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-2-R-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-2-RZ-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-2-V-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-02-2-W-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-2G-1-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-2G-1-[0,​B,​C,​D,​E,​F,​K,​N,​V,​W]-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-2G-1-[H,​J,​L,​M,​P,​R]-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-2G-1-[H,​J,​L,​M,​P,​R]Z-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-2G-2-0-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-2G-2-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-2G-2-B-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-2G-2-C-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-2G-2-D-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-2G-2-E-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-2G-2-F-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-2G-2-H-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-2G-2-HZ-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
AG41-2G-2-J-[AC100V,​AC200V,​DC12V,​DC24V,​DC48V,​DC100V]
Part NumberMinimum order quantityVolume DiscountDays to ShipConnection Type Plumbing Thread Nominal Orifice Dia.
(Ø)
Orifice Dia (Top) (φ) Body Material Sealing Material Special Specification
1 Piece(s) 27 Day(s) or more Rc1/422.0-NBR (with Option)NA
1 Piece(s) 27 Day(s) or more Rc1/422.0-NBR (Without Option)NA
1 Piece(s) 27 Day(s) or more Rc1/422.0-FKMNA
1 Piece(s) 27 Day(s) or more Rc1/422.0-PTFENA
1 Piece(s) 27 Day(s) or more Rc1/422.0-NBRNA
1 Piece(s) 27 Day(s) or more Rc1/422.0-FKMNA
1 Piece(s) 27 Day(s) or more Rc1/422.0-PTFENA
1 Piece(s) 27 Day(s) or more Rc1/422.0-NBR, No Oil TreatmentNA
1 Piece(s) 27 Day(s) or more Rc1/422.0-NBR, No Oil TreatmentFor Dry Air
1 Piece(s) 27 Day(s) or more Rc1/422.0-FKM, No Oil TreatmentNA
1 Piece(s) 27 Day(s) or more Rc1/422.0-FKM, No Oil TreatmentFor Dry Air
1 Piece(s) 27 Day(s) or more Rc1/422.0-PTFE, No Oil TreatmentNA
1 Piece(s) 27 Day(s) or more Rc1/422.0-NBR, No Oil TreatmentNA
1 Piece(s) 27 Day(s) or more Rc1/422.0-NBR, No Oil TreatmentFor Dry Air
1 Piece(s) 27 Day(s) or more Rc1/422.0-FKM, No Oil TreatmentNA
1 Piece(s) 27 Day(s) or more Rc1/422.0-FKM, No Oil TreatmentFor Dry Air
1 Piece(s) 27 Day(s) or more Rc1/422.0-PTFE, No Oil TreatmentNA
1 Piece(s) 27 Day(s) or more Rc1/422.0-EPDM, No Oil TreatmentNA
1 Piece(s) 27 Day(s) or more Rc1/422.0-EPDM, No Oil TreatmentFor Dry Air
1 Piece(s) 27 Day(s) or more Rc1/422.0-EPDM, No Oil TreatmentNA
1 Piece(s) 27 Day(s) or more Rc1/422.0-EPDM, No Oil TreatmentFor Dry Air
1 Piece(s) 27 Day(s) or more Rc1/422.0-FKM, Vacuum InspectionNA
1 Piece(s) 27 Day(s) or more Rc1/422.0-FKM, Vacuum InspectionNA
1 Piece(s) 50 Day(s) or more Rc1/42.32.3-NBR (with Option)NA
1 Piece(s) 50 Day(s) or more Rc1/42.32.3-NBR (Without Option)NA
1 Piece(s) 50 Day(s) or more Rc1/42.32.3-FKMNA
1 Piece(s) 50 Day(s) or more Rc1/42.32.3-PTFENA
1 Piece(s) 50 Day(s) or more Rc1/42.32.3-NBRNA
1 Piece(s) 50 Day(s) or more Rc1/42.32.3-FKMNA
1 Piece(s) 50 Day(s) or more Rc1/42.32.3-PTFENA
1 Piece(s) 50 Day(s) or more Rc1/42.32.3-NBR, No Oil TreatmentNA
1 Piece(s) 50 Day(s) or more Rc1/42.32.3-NBR, No Oil TreatmentFor Dry Air
1 Piece(s) 50 Day(s) or more Rc1/42.32.3-FKM, No Oil TreatmentNA
1 Piece(s) 50 Day(s) or more Rc1/42.32.3-FKM, No Oil TreatmentFor Dry Air
1 Piece(s) 50 Day(s) or more Rc1/42.32.3-PTFE, No Oil TreatmentNA
1 Piece(s) 50 Day(s) or more Rc1/42.32.3-NBR, No Oil TreatmentNA
1 Piece(s) 50 Day(s) or more Rc1/42.32.3-NBR, No Oil TreatmentFor Dry Air
1 Piece(s) 50 Day(s) or more Rc1/42.32.3-FKM, No Oil TreatmentNA
1 Piece(s) 50 Day(s) or more Rc1/42.32.3-FKM, No Oil TreatmentFor Dry Air
1 Piece(s) 50 Day(s) or more Rc1/42.32.3-PTFE, No Oil TreatmentNA
1 Piece(s) 50 Day(s) or more Rc1/42.32.3-EPDM, No Oil TreatmentNA
1 Piece(s) 50 Day(s) or more Rc1/42.32.3-EPDM, No Oil TreatmentFor Dry Air
1 Piece(s) 50 Day(s) or more Rc1/42.32.3-EPDM, No Oil TreatmentNA
1 Piece(s) 50 Day(s) or more Rc1/42.32.3-EPDM, No Oil TreatmentFor Dry Air
1 Piece(s) 50 Day(s) or more Rc1/42.32.3-FKM, Vacuum InspectionNA
1 Piece(s) 50 Day(s) or more Rc1/42.32.3-FKM, Vacuum InspectionNA
1 Piece(s) 77 Day(s) or more G1/422.0Stainless steel-NA
1 Piece(s) 77 Day(s) or more G1/422.0Stainless steelPTFE, No Oil TreatmentNA
1 Piece(s) 77 Day(s) or more G1/422.0Stainless steelEPDM, No Oil Treatment / FKM, No Oil TreatmentNA
1 Piece(s) 77 Day(s) or more G1/422.0Stainless steelEPDM, No Oil Treatment / FKM, No Oil TreatmentFor Dry Air
1 Piece(s) 77 Day(s) or more G1/42.32.3--NA
1 Piece(s) 77 Day(s) or more G1/42.32.3--NA
1 Piece(s) 77 Day(s) or more G1/42.32.3--NA
1 Piece(s) 77 Day(s) or more G1/42.32.3--NA
1 Piece(s) 77 Day(s) or more G1/42.32.3-NBRNA
1 Piece(s) 77 Day(s) or more G1/42.32.3-FKMNA
1 Piece(s) 77 Day(s) or more G1/42.32.3-PTFENA
1 Piece(s) 77 Day(s) or more G1/42.32.3-NBR, No Oil TreatmentNA
1 Piece(s) 77 Day(s) or more G1/42.32.3-NBR, No Oil TreatmentFor Dry Air
1 Piece(s) 77 Day(s) or more G1/42.32.3-FKM, No Oil TreatmentNA

Loading...

Basic Information

Type Electromagnetic Applicable Fluid Air / Water / Vacuum / Oil / Gas Operating Environment Standard
Switching Type 3 Port Universal Driving Type Linear Motion Type Number of Solenoids Single
Application Single Item

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:021-8990-4102 / FAX:021-8990-5803