(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Pembayaran dengan kartu kredit untuk sementara tidak tersedia karena kendala sistem. Sementara waktu Anda dapat meggunakan metode Pembayaran di Muka atau QRIS. Untuk informasi lebih lanjut, silakan hubungi Customer Service : TEL: 021-8984-0008 E-mail: cs@misumi.co.id. WA: 08118984008. Kami mohon maaf atas ketidaknyamanan yang terjadi.
    Credit card payments are temporarily unavailable due to system issues. Meanwhile, you can use the Advance Payment method or QRIS. For further information, please contact Customer Service: TEL: 021-8984-0008 E-mail: cs@misumi.co.id. WA: 08118984008. We apologize for any inconvenience caused.
  • Pemberitahuan Jadwal Pemeliharaan : Situs ini akan tidak tersedia dikarenaka jadwal pemeliharaan mulai dari 8:00 21/4/2024 sampai dengan 5:00 pada tanggal 22/4/2024. Kami mohon maaf atas ketidaknyamanan yang terjadi.
    Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 8:00 21/4/2024 to 5:00 (WIB) 22/4/2024. We apologize for the inconvenience.
  • Sehubungan dengan adanya Peraturan Baru Kementerian Perdagangan No.36 Tahun 2023 tentang Pembatasan Impor Barang, MISUMI Indonesia melakukan tindakan pencegahan. Lihat informasi detailnya di sini
    Due to New Regulation of Ministry Of Trade No.36 of 2023 concerning retrictions on imports of goods, MISUMI Indonesia do precautions measure. See detail information here

Internal Pilot-Operated Type 3 Port Valve, Mounted Type Solenoid Valve NP13/NP14 Series

Internal Pilot-Operated Type 3 Port Valve, Mounted Type Solenoid Valve NP13/NP14 Series

Internal pilot-operated 3-port valve equipped with solenoid valve.
[Features]
·NC (open when energized) type, NO (closed when energized) type.
·Connection port diameter: Rc3/8 to Rc2.
[Application]
·Ideal for controlling compressed air.

(i)Caution

  • Some of the items are scheduled to be discontinued as of end of March in 2023. The manufacturer keep the items produced but they are not available with Misumi.
    There are not the replacement items and the plan to resumption of sale. Please check the quotation and order screen for details.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

Part Number
NP13-10A-12C-1
NP13-10A-12C-2
NP13-10A-12C-3
NP13-10A-12CS-1
NP13-10A-12CS-2
NP13-10A-12CS-3
NP13-10A-12G-1
NP13-10A-12G-2
NP13-10A-12G-3
NP13-10A-12GS-1
NP13-10A-12GS-2
NP13-10A-12GS-3
NP13-10A-12H-1
NP13-10A-12H-2
NP13-10A-12H-3
NP13-10A-12HS-2
NP13-10A-12HS-3
NP13-10A-13R-1
NP13-10A-13R-2
NP13-10A-13R-3
NP13-10A-13RS-1
NP13-10A-13RS-3
NP13-10A-13T-1
NP13-10A-13T-2
NP13-10A-13T-3
NP13-10A-13TS-3
NP13-15A-12C-2
NP13-15A-12C-3
NP13-15A-12CS-1
NP13-15A-12CS-2
NP13-15A-12CS-3
NP13-15A-12G-1
NP13-15A-12G-2
NP13-15A-12G-3
NP13-15A-12GS-1
NP13-15A-12GS-2
NP13-15A-12GS-3
NP13-15A-12H-1
NP13-15A-12H-2
NP13-15A-12H-3
NP13-15A-12HS-1
NP13-15A-12HS-2
NP13-15A-12HS-3
NP13-15A-13R-1
NP13-15A-13R-2
NP13-15A-13R-3
NP13-15A-13RS-1
NP13-15A-13RS-3
NP13-15A-13T-1
NP13-15A-13T-2
NP13-15A-13TS-3
NP13-20A-12C-1
NP13-20A-12C-2
NP13-20A-12C-3
NP13-20A-12CS-3
NP13-20A-12G-1
NP13-20A-12G-2
NP13-20A-12G-3
NP13-20A-12GS-1
NP13-20A-12GS-3
Part NumberMinimum order quantityVolume DiscountDays to ShipSwitching Type Voltage Plumbing Thread Nominal CV Value Coil Symbol Surge Suppressor
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedAC100V3/83.42CWithout Options (standard)
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedAC200V3/83.42CWithout Options (standard)
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedDC24V3/83.42CWithout Options (standard)
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedAC100V3/83.42CS: Surge suppressor equipped
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedAC200V3/83.42CS: Surge suppressor equipped
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedDC24V3/83.42CS: Surge suppressor equipped
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedAC100V3/83.42GWithout Options (standard)
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedAC200V3/83.42GWithout Options (standard)
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedDC24V3/83.42GWithout Options (standard)
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedAC100V3/83.42GS: Surge suppressor equipped
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedAC200V3/83.42GS: Surge suppressor equipped
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedDC24V3/83.42GS: Surge suppressor equipped
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedAC100V3/83.42HWithout Options (standard)
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedAC200V3/83.42HWithout Options (standard)
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedDC24V3/83.42HWithout Options (standard)
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedAC200V3/83.42HS: Surge suppressor equipped
1 Piece(s) 18 Day(s) or more 2-position Normally ClosedDC24V3/83.42HS: Surge suppressor equipped
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedAC100V3/83.43RWithout Options (standard)
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedAC200V3/83.43RWithout Options (standard)
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedDC24V3/83.43RWithout Options (standard)
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedAC100V3/83.43RS: Surge suppressor equipped
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedDC24V3/83.43RS: Surge suppressor equipped
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedAC100V3/83.43TWithout Options (standard)
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedAC200V3/83.43TWithout Options (standard)
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedDC24V3/83.43TWithout Options (standard)
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedDC24V3/83.43TS: Surge suppressor equipped
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedAC200V1/23.62CWithout Options (standard)
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedDC24V1/23.62CWithout Options (standard)
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedAC100V1/23.62CS: Surge suppressor equipped
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedAC200V1/23.62CS: Surge suppressor equipped
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedDC24V1/23.62CS: Surge suppressor equipped
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedAC100V1/23.62GWithout Options (standard)
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedAC200V1/23.62GWithout Options (standard)
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedDC24V1/23.62GWithout Options (standard)
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedAC100V1/23.62GS: Surge suppressor equipped
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedAC200V1/23.62GS: Surge suppressor equipped
1 Piece(s) 18 Day(s) or more 2-position Normally ClosedDC24V1/23.62GS: Surge suppressor equipped
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedAC100V1/23.62HWithout Options (standard)
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedAC200V1/23.62HWithout Options (standard)
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedDC24V1/23.62HWithout Options (standard)
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedAC100V1/23.62HS: Surge suppressor equipped
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedAC200V1/23.62HS: Surge suppressor equipped
1 Piece(s) 18 Day(s) or more 2-position Normally ClosedDC24V1/23.62HS: Surge suppressor equipped
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedAC100V1/23.63RWithout Options (standard)
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedAC200V1/23.63RWithout Options (standard)
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedDC24V1/23.63RWithout Options (standard)
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedAC100V1/23.63RS: Surge suppressor equipped
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedDC24V1/23.63RS: Surge suppressor equipped
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedAC100V1/23.63TWithout Options (standard)
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedAC200V1/23.63TWithout Options (standard)
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedDC24V1/23.63TS: Surge suppressor equipped
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedAC100V3/48.42CWithout Options (standard)
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedAC200V3/48.42CWithout Options (standard)
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedDC24V3/48.42CWithout Options (standard)
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedDC24V3/48.42CS: Surge suppressor equipped
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedAC100V3/48.42GWithout Options (standard)
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedAC200V3/48.42GWithout Options (standard)
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedDC24V3/48.42GWithout Options (standard)
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedAC100V3/48.42GS: Surge suppressor equipped
1 Piece(s) 22 Day(s) or more 2-position Normally ClosedDC24V3/48.42GS: Surge suppressor equipped

Loading...

Basic Information

Type Electromagnetic Valve Application Single Item Operating Number of Ports 3-port valve
Mounting Orientation Direct Specifications Standard / Oil-Free Number of Solenoids Single
Status at Power Off Self-reset(differential pressure spring return) Pipe Port Type Rc Plumbing Direct piping
Driving Type Pilot-Operated Poppet Seal Type Soft seal Pilot Air Supply Internal
Manual Equipment Non-Locking Combination of Material (Body / Seal) Aluminum / nitrile rubber

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:021-8990-4102 / FAX:021-8990-5803
8:30am - 5:30pm (Monday - Friday)