(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Pembayaran dengan kartu kredit untuk sementara tidak tersedia karena kendala sistem. Sementara waktu Anda dapat meggunakan metode Pembayaran di Muka atau QRIS. Untuk informasi lebih lanjut, silakan hubungi Customer Service : TEL: 021-8984-0008 E-mail: cs@misumi.co.id. WA: 08118984008. Kami mohon maaf atas ketidaknyamanan yang terjadi.
    Credit card payments are temporarily unavailable due to system issues. Meanwhile, you can use the Advance Payment method or QRIS. For further information, please contact Customer Service: TEL: 021-8984-0008 E-mail: cs@misumi.co.id. WA: 08118984008. We apologize for any inconvenience caused.
  • Sehubungan dengan adanya Peraturan Baru Kementerian Perdagangan No.36 Tahun 2023 tentang Pembatasan Impor Barang, MISUMI Indonesia melakukan tindakan pencegahan. Lihat informasi detailnya di sini
    Due to New Regulation of Ministry Of Trade No.36 of 2023 concerning retrictions on imports of goods, MISUMI Indonesia do precautions measure. See detail information here
  • Nomor telepon alternatif Kontak Layanan Pelanggan : 021-29182911| 021-29182991 | 021-29182997 | 021-29182998
    Alternative telephone number Contact Customer Service: 021-29182911 | 021-29182991 | 021-29182997 | 021-29182998

Temperature Controller (Digital Control Meter) (22.5 mm Width, DIN Rail-Mounted Type) [E5DC/E5DC-B]

Temperature Controller (Digital Control Meter) (22.5 mm Width, DIN Rail-Mounted Type) [E5DC/E5DC-B]

Ideal DIN rail mounting type for a system that connects a touch panel / PLC and a temperature controller while maintaining the operability and high performance of the E5□C type series.
Added push-in Plus terminal block type lineup.
[Features]
・ A slim body that fits in a low profile control panel with a DIN rail mounting type with a depth of 85 mm and a width of 22.5 mm
・ Easy-to-replace terminal block attachment/detachment structure improves maintainability
・ In addition to the screw terminal block type, you can select from the push-in Plus terminal block type that reduces wiring man-hours
・ Push-in Plus terminal block type is a connector and does not require wiring of power supply / communication line (Maximum number of connected units: 16)
・ High-speed sampling 50 ms makes it suitable for high-speed heating apps
・ Easy connection with PLC by programless communication
·By using a communication conversion cable (sold separately) to connect to a computer, settings can be configured without power wiring. Easy to set up from CX-Thermo (sold separately)
・ Enhanced basic functions of auxiliary output (2 points maximum) and event input (1 point maximum)
・ Easy-to-read white PV display that makes it easy to check when starting up or when something is wrong even inside the panel (PV height: 8.5 mm)

PDF

Japanese Only

Part Number

Configured Part Number is shown.

 
Part Number
E5DC-CX0ASM-015
E5DC-CX0DSM-015
E5DC-CX2ASM-000
E5DC-CX2ASM-016
E5DC-CX2DSM-000
E5DC-CX2DSM-015
E5DC-CX2DSM-016
E5DC-QX2ASM-000
E5DC-QX2ASM-017
E5DC-QX2DSM-017
E5DC-RX0ASM-015
E5DC-RX0DSM-015
E5DC-RX2DSM-000
E5DC-RX2DSM-002
Part NumberMinimum order quantityVolume DiscountDays to ShipRoHSOutput Type Failure Detecting Function Power Supply Voltage
(V)
Control Output 1 Auxiliary output points Event Input
(Point)
Heater Breakage, SSR Fault Detection Capability
1 Piece(s) 16 Day(s) or more -Current-100 to 240 VACLinear voltage outputNoneNone-
1 Piece(s) 16 Day(s) or more -Current-24 VAC/DCLinear voltage outputNoneNone-
1 Piece(s) 16 Day(s) or more -Current-100 to 240 VACLinear voltage output2 (one common)None-
1 Piece(s) 16 Day(s) or more -Current-100 to 240 VACLinear voltage output2 (one common)1-
1 Piece(s) 16 Day(s) or more -Current-24 VAC/DCLinear voltage output2 (one common)None-
1 Piece(s) 16 Day(s) or more -Current-24 VAC/DCLinear voltage output2 (one common)None-
1 Piece(s) 16 Day(s) or more -Current-24 VAC/DCLinear voltage output2 (one common)1-
1 Piece(s) 16 Day(s) or more -SSR Drive Output Voltage-100 to 240 VACVoltage output (for driving SSR)2 (one common)None-
1 Piece(s) 16 Day(s) or more -SSR Drive Output VoltageHeater Breakage / SSR Breakdown100 to 240 VACVoltage output (for driving SSR)2 (one common)11
1 Piece(s) 16 Day(s) or more -SSR Drive Output VoltageHeater Breakage / SSR Breakdown24 VAC/DCVoltage output (for driving SSR)2 (one common)11
1 Piece(s) 16 Day(s) or more -Relay contact-100 to 240 VACRelay OutputNoneNone-
1 Piece(s) 16 Day(s) or more -Relay contact-24 VAC/DCRelay OutputNoneNone-
1 Piece(s) Same day 10Relay contact-24 VAC/DCRelay Output2 (one common)None-
1 Piece(s) 16 Day(s) or more -Relay contactHeater Breakage / SSR Breakdown24 VAC/DCRelay Output2 (one common)None1

Loading...

  1. 1

Basic Information

Number of Control Points 1 Number of Input Points(pcs.) 1 Acquired Standards UL / CSA / CE
Type Temperature Controller / Controller Control Output 2 No

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:021-8990-4102 / FAX:021-8990-5803
8:30am - 5:30pm (Monday - Friday)