(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Pembayaran dengan kartu kredit untuk sementara tidak tersedia karena kendala sistem. Sementara waktu Anda dapat meggunakan metode Pembayaran di Muka atau QRIS. Untuk informasi lebih lanjut, silakan hubungi Customer Service : TEL: 021-8984-0008 E-mail: cs@misumi.co.id. WA: 08118984008. Kami mohon maaf atas ketidaknyamanan yang terjadi.
    Credit card payments are temporarily unavailable due to system issues. Meanwhile, you can use the Advance Payment method or QRIS. For further information, please contact Customer Service: TEL: 021-8984-0008 E-mail: cs@misumi.co.id. WA: 08118984008. We apologize for any inconvenience caused.
  • Pemberitahuan Jadwal Pemeliharaan : Situs ini akan tidak tersedia dikarenaka jadwal pemeliharaan mulai dari 8:00 21/4/2024 sampai dengan 5:00 pada tanggal 22/4/2024. Kami mohon maaf atas ketidaknyamanan yang terjadi.
    Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 8:00 21/4/2024 to 5:00 (WIB) 22/4/2024. We apologize for the inconvenience.
  • Sehubungan dengan adanya Peraturan Baru Kementerian Perdagangan No.36 Tahun 2023 tentang Pembatasan Impor Barang, MISUMI Indonesia melakukan tindakan pencegahan. Lihat informasi detailnya di sini
    Due to New Regulation of Ministry Of Trade No.36 of 2023 concerning retrictions on imports of goods, MISUMI Indonesia do precautions measure. See detail information here

Temperature Controller (Digital Control Meter) [E5CC]

Temperature Controller (Digital Control Meter) [E5CC]
  • On Sale Till 30/06/2024
  • Volume Discount

A large white PV display realizes high visibility. Pursuing ease of use from selection to operation and setting. Added push-in Plus terminal block type lineup.
[Features]
・ Height of 15.2 mm, white PV display is used to improve visibility
・ Realization of high-speed sampling 50 ms
・ In addition to the screw terminal block type, you can select from the push-in Plus terminal block type that reduces wiring man-hours and the plug-in type that allows the terminal block to be attached and detached
・ Slim body with a depth of 60 mm (Screw terminal block type)
・ Easy connection with PLC by programless communication function. Coordination between temperature control is possible by component communication
·By using a communication exchange cable (sold separately) to connect to a computer, settings can be made without wiring the power supply. Easy to set up from CX-Thermo (sold separately)

PDF

Japanese Only


 
Part Number
E5CC-CX0AUM-000
E5CC-CX0DSM-000
E5CC-CX1AUM-000
E5CC-CX2ASM-004
E5CC-CX2ASM-005
E5CC-CX2ASM-006
E5CC-CX2ASM-007
E5CC-CX2AUM-000
E5CC-CX2DSM-000
E5CC-CX2DSM-004
E5CC-CX2DSM-006
E5CC-CX3ASM-000
E5CC-CX3ASM-004
E5CC-CX3ASM-006
E5CC-CX3DSM-000
E5CC-CX3DSM-006
E5CC-QQ2ASM-001
E5CC-QQ2ASM-003
E5CC-QQ3ASM-002
E5CC-QX0ASM-000
E5CC-QX0AUM-000
E5CC-QX0DSM-000
E5CC-QX1AUM-000
E5CC-QX2ABM-000
E5CC-QX2ABM-001
E5CC-QX2ABM-002
E5CC-QX2ABM-006
E5CC-QX2ASM-000
E5CC-QX2ASM-001
E5CC-QX2ASM-002
E5CC-QX2ASM-003
E5CC-QX2ASM-004
E5CC-QX2ASM-005
E5CC-QX2ASM-006
E5CC-QX2ASM-007
E5CC-QX2AUM-000
E5CC-QX2DBM-000
E5CC-QX2DBM-001
E5CC-QX2DBM-002
E5CC-QX2DBM-006
E5CC-QX2DSM-000
E5CC-QX2DSM-001
E5CC-QX2DSM-002
E5CC-QX2DSM-003
E5CC-QX2DSM-004
E5CC-QX2DSM-005
E5CC-QX2DSM-006
E5CC-QX3ASM-000
E5CC-QX3ASM-001
E5CC-QX3ASM-002
E5CC-QX3ASM-003
E5CC-QX3ASM-004
E5CC-QX3ASM-006
E5CC-QX3DSM-000
E5CC-QX3DSM-001
E5CC-QX3DSM-002
E5CC-QX3DSM-004
E5CC-RW0AUM-000
E5CC-RW0DUM-000
E5CC-RW1AUM-000
Part NumberMinimum order quantityVolume DiscountDays to ShipRoHSOutput Type Number of Control Points Setting Method Failure Detecting Function Power Supply Voltage
(V)
Control Output 1 Control Output 2 Auxiliary output points Terminal shape Event Input
(Point)
Heater Breakage, SSR Fault Detection Capability Program type Communication Remote SP input Transmission input
1 Piece(s) 16 Day(s) or more --1--100 to 240 VACLinear current outputNoNonePlug-Ins TypeNone-Simplicity---
1 Piece(s) 16 Day(s) or more --1--24 VAC/DCLinear current outputNoNoneScrew terminal Block TypeNone-Simplicity---
1 Piece(s) 16 Day(s) or more --1--100 to 240 VACLinear current outputNo1Plug-Ins TypeNone-Simplicity---
1 Piece(s) 16 Day(s) or more --1--100 to 240 VACLinear current outputNo2 independentScrew terminal Block Type2-SimplicityRS-485--
1 Piece(s) 16 Day(s) or more --1--100 to 240 VACLinear current outputNo2 independentScrew terminal Block Type4-Simplicity---
1 Piece(s) 16 Day(s) or more --1--100 to 240 VACLinear current outputNo2 independentScrew terminal Block Type2-Simplicity--Presence
1 Piece(s) 16 Day(s) or more --1Key inputNo100 to 240 VACLinear current outputNo2 independentScrew terminal Block Type2---Presence-
1 Piece(s) 16 Day(s) or more --1--100 to 240 VACLinear current outputNo2 independentPlug-Ins TypeNone-Simplicity---
1 Piece(s) 18 Day(s) or more --1--24 VAC/DCLinear current outputNo2 independentScrew terminal Block TypeNone-Simplicity---
1 Piece(s) 16 Day(s) or more --1--24 VAC/DCLinear current outputNo2 independentScrew terminal Block Type2-SimplicityRS-485--
1 Piece(s) 16 Day(s) or more --1--24 VAC/DCLinear current outputNo2 independentScrew terminal Block Type2-Simplicity--Presence
1 Piece(s) 16 Day(s) or more --1--100 to 240 VACLinear current outputNo3 (one common)Screw terminal Block TypeNone-Simplicity---
1 Piece(s) 16 Day(s) or more --1--100 to 240 VACLinear current outputNo3 (one common)Screw terminal Block Type2-SimplicityRS-485--
1 Piece(s) 16 Day(s) or more --1--100 to 240 VACLinear current outputNo3 (one common)Screw terminal Block Type2-Simplicity--Presence
1 Piece(s) 16 Day(s) or more --1--24 VAC/DCLinear current outputNo3 (one common)Screw terminal Block TypeNone-Simplicity---
1 Piece(s) 16 Day(s) or more --1--24 VAC/DCLinear current outputNo3 (one common)Screw terminal Block Type2-Simplicity--Presence
1 Piece(s) 16 Day(s) or more --2-Heater Breakage / SSR Breakdown100 to 240 VACVoltage output (for driving SSR)Voltage Output (for SSR Drive)2 independentScrew terminal Block Type21Simplicity---
1 Piece(s) 16 Day(s) or more --2-Heater Breakage / SSR Breakdown100 to 240 VACVoltage output (for driving SSR)Voltage Output (for SSR Drive)2 independentScrew terminal Block TypeNone2 (for 3-phase heaters)Simplicity---
1 Piece(s) 16 Day(s) or more -SSR Drive Output Voltage2Key inputHeater Breakage100 to 240 VACVoltage output (for driving SSR)Voltage Output (for SSR Drive)3 (one common)Screw terminal Block TypeNone1-RS-485--
1 Piece(s) Same day 10-1--100 to 240 VACVoltage output (for driving SSR)NoNoneScrew terminal Block TypeNone-Simplicity---
1 Piece(s) 16 Day(s) or more --1--100 to 240 VACVoltage output (for driving SSR)NoNonePlug-Ins TypeNone-Simplicity---
1 Piece(s) Same day 10-1--24 VAC/DCVoltage output (for driving SSR)NoNoneScrew terminal Block TypeNone-Simplicity---
1 Piece(s) Same day 10-1--100 to 240 VACVoltage output (for driving SSR)No1Plug-Ins TypeNone-Simplicity---
1 Piece(s) 16 Day(s) or more -SSR Drive Output Voltage1Key inputNo100 to 240 VACVoltage output (for driving SSR)No2 (one common)Plug-Ins TypeNone-----
1 Piece(s) 16 Day(s) or more -SSR Drive Output Voltage1Key inputHeater Breakage100 to 240 VACVoltage output (for driving SSR)No2 (one common)Plug-Ins Type21----
1 Piece(s) 16 Day(s) or more -SSR Drive Output Voltage1Key inputHeater Breakage100 to 240 VACVoltage output (for driving SSR)No2 (one common)Plug-Ins TypeNone1-RS-485--
1 Piece(s) 16 Day(s) or more -SSR Drive Output Voltage1Key inputNo100 to 240 VACVoltage output (for driving SSR)No2 (one common)Plug-Ins Type2----Presence
1 Piece(s) Same day 10-1--100 to 240 VACVoltage output (for driving SSR)No2 independentScrew terminal Block TypeNone-Simplicity---
1 Piece(s) Same day 10-1-Heater Breakage / SSR Breakdown100 to 240 VACVoltage output (for driving SSR)No2 independentScrew terminal Block Type21Simplicity---
1 Piece(s) 16 Day(s) or more --1-Heater Breakage / SSR Breakdown100 to 240 VACVoltage output (for driving SSR)No2 independentScrew terminal Block TypeNone1Simplicity---
1 Piece(s) 16 Day(s) or more --1-Heater Breakage / SSR Breakdown100 to 240 VACVoltage output (for driving SSR)No2 independentScrew terminal Block TypeNone2 (for 3-phase heaters)Simplicity---
1 Piece(s) 16 Day(s) or more --1--100 to 240 VACVoltage output (for driving SSR)No2 independentScrew terminal Block Type2-SimplicityRS-485--
1 Piece(s) 16 Day(s) or more -SSR Drive Output Voltage1Key inputNo100 to 240 VACVoltage output (for driving SSR)No2 independentScrew terminal Block Type4-----
1 Piece(s) 15 Day(s) or more --1--100 to 240 VACVoltage output (for driving SSR)No2 independentScrew terminal Block Type2-Simplicity--Presence
1 Piece(s) 16 Day(s) or more --1--100 to 240 VACVoltage output (for driving SSR)No2 independentScrew terminal Block Type2-Simplicity-Presence-
1 Piece(s) 16 Day(s) or more --1--100 to 240 VACVoltage output (for driving SSR)No2 independentPlug-Ins TypeNone-Simplicity---
1 Piece(s) 16 Day(s) or more -SSR Drive Output Voltage1Key inputNo24 VAC/DCVoltage output (for driving SSR)No2 (one common)Plug-Ins TypeNone-----
1 Piece(s) 16 Day(s) or more -SSR Drive Output Voltage1Key inputHeater Breakage24 VAC/DCVoltage output (for driving SSR)No2 (one common)Plug-Ins Type21----
1 Piece(s) 16 Day(s) or more -SSR Drive Output Voltage1Key inputHeater Breakage24 VAC/DCVoltage output (for driving SSR)No2 (one common)Plug-Ins TypeNone1-RS-485--
1 Piece(s) 16 Day(s) or more -SSR Drive Output Voltage1Key inputNo24 VAC/DCVoltage output (for driving SSR)No2 (one common)Plug-Ins Type2----Presence
1 Piece(s) Same day 10-1--24 VAC/DCVoltage output (for driving SSR)No2 independentScrew terminal Block TypeNone-Simplicity---
1 Piece(s) Same day 10-1-Heater Breakage / SSR Breakdown24 VAC/DCVoltage output (for driving SSR)No2 independentScrew terminal Block Type21Simplicity---
1 Piece(s) 16 Day(s) or more --1-Heater Breakage / SSR Breakdown24 VAC/DCVoltage output (for driving SSR)No2 independentScrew terminal Block TypeNone1Simplicity---
1 Piece(s) 16 Day(s) or more --1-Heater Breakage / SSR Breakdown24 VAC/DCVoltage output (for driving SSR)No2 independentScrew terminal Block TypeNone2 (for 3-phase heaters)Simplicity---
1 Piece(s) Same day 10-1--24 VAC/DCVoltage output (for driving SSR)No2 independentScrew terminal Block Type2-SimplicityRS-485--
1 Piece(s) 16 Day(s) or more -SSR Drive Output Voltage1Key inputNo24 VAC/DCVoltage output (for driving SSR)No2 independentScrew terminal Block Type4-----
1 Piece(s) 16 Day(s) or more --1--24 VAC/DCVoltage output (for driving SSR)No2 independentScrew terminal Block Type2-Simplicity--Presence
1 Piece(s) 16 Day(s) or more --1--100 to 240 VACVoltage output (for driving SSR)No3 (one common)Screw terminal Block TypeNone-Simplicity---
1 Piece(s) 16 Day(s) or more --1-Heater Breakage / SSR Breakdown100 to 240 VACVoltage output (for driving SSR)No3 (one common)Screw terminal Block Type21Simplicity---
1 Piece(s) 16 Day(s) or more --1-Heater Breakage / SSR Breakdown100 to 240 VACVoltage output (for driving SSR)No3 (one common)Screw terminal Block TypeNone1Simplicity---
1 Piece(s) 16 Day(s) or more --1-Heater Breakage / SSR Breakdown100 to 240 VACVoltage output (for driving SSR)No3 (one common)Screw terminal Block TypeNone2 (for 3-phase heaters)Simplicity---
1 Piece(s) 16 Day(s) or more --1--100 to 240 VACVoltage output (for driving SSR)No3 (one common)Screw terminal Block Type2-SimplicityRS-485--
1 Piece(s) 16 Day(s) or more --1--100 to 240 VACVoltage output (for driving SSR)No3 (one common)Screw terminal Block Type2-Simplicity--Presence
1 Piece(s) 16 Day(s) or more --1--24 VAC/DCVoltage output (for driving SSR)No3 (one common)Screw terminal Block TypeNone-Simplicity---
1 Piece(s) 16 Day(s) or more --1-Heater Breakage / SSR Breakdown24 VAC/DCVoltage output (for driving SSR)No3 (one common)Screw terminal Block Type21Simplicity---
1 Piece(s) 16 Day(s) or more --1-Heater Breakage / SSR Breakdown24 VAC/DCVoltage output (for driving SSR)No3 (one common)Screw terminal Block TypeNone1Simplicity---
1 Piece(s) 16 Day(s) or more --1--24 VAC/DCVoltage output (for driving SSR)No3 (one common)Screw terminal Block Type2-SimplicityRS-485--
1 Piece(s) 16 Day(s) or more --1--100 to 240 VACRelay OutputNoNonePlug-Ins TypeNone-Simplicity---
1 Piece(s) 16 Day(s) or more --1--24 VAC/DCRelay OutputNoNonePlug-Ins TypeNone-Simplicity---
1 Piece(s) Same day 10-1--100 to 240 VACRelay OutputNo1Plug-Ins TypeNone-Simplicity---

Loading...

Basic Information

Control Method ON/OFF Control / PID control with auto tuning Number of Input Points(pcs.) 1 Input type Full multi-input

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:021-8990-4102 / FAX:021-8990-5803
8:30am - 5:30pm (Monday - Friday)