(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Pembayaran dengan kartu kredit untuk sementara tidak tersedia karena kendala sistem. Sementara waktu Anda dapat meggunakan metode Pembayaran di Muka atau QRIS. Untuk informasi lebih lanjut, silakan hubungi Customer Service : TEL: 021-8984-0008 E-mail: cs@misumi.co.id. WA: 08118984008. Kami mohon maaf atas ketidaknyamanan yang terjadi.
    Credit card payments are temporarily unavailable due to system issues. Meanwhile, you can use the Advance Payment method or QRIS. For further information, please contact Customer Service: TEL: 021-8984-0008 E-mail: cs@misumi.co.id. WA: 08118984008. We apologize for any inconvenience caused.
  • Sehubungan dengan adanya Peraturan Baru Kementerian Perdagangan No.36 Tahun 2023 tentang Pembatasan Impor Barang, MISUMI Indonesia melakukan tindakan pencegahan. Lihat informasi detailnya di sini
    Due to New Regulation of Ministry Of Trade No.36 of 2023 concerning retrictions on imports of goods, MISUMI Indonesia do precautions measure. See detail information here
  • Nomor telepon alternatif Kontak Layanan Pelanggan : 021-29182911| 021-29182991 | 021-29182997 | 021-29182998
    Alternative telephone number Contact Customer Service: 021-29182911 | 021-29182991 | 021-29182997 | 021-29182998

Digital Pressure Sensor GS40 Series

Digital Pressure Sensor GS40 Series

[Features]
· Multiple functions
Pressure sensor and switch have been combined, reducing mounting space and labor hours
· Built-in semiconductor sensor and microcontroller

(i)Caution

  • Product images may be representative images. Refer to the manufacturer's catalog for details

PDF

Specifications of Digital Pressure Sensor GS40 Series

External appearance of digital pressure sensor GS40 Series

External appearance of digital pressure sensor GS40 Series

ModelGS40-M5GS40-01GS40-02
FluidAir and inert gas
Hysteresis3% F.S. (full span) or less
Accuracy±3%F.S.(+5~+40℃), ±5%F.S. (-5~+60℃)
Operating voltage12 to 24 V DC (Ripple ±10% or less)
OutputOpen collector 30 V, 80 mA or less
Indicator lightLights when ON (ON when the pressure drops below the setting value.)
Current Consumption15 mA (24 V DC, when light is ON) or less
Maximum operating pressure0.98 MPa
Operating temperature range-5~+60℃ (No freezing)
Sampling frequency4 Hz
Bracket15501--
Connection port sizeM5 × 0.8 (female thread)R1/8R1/4
Weight (g)425457

Dimensions

 

(Units: mm)

 

· External appearance 1 of GS40 Series

External appearance 1 of GS40 Series

· Dimensional drawing 2 of GS40 Series

Dimensional drawing 2 of GS40 Series

External appearance of M (fixed SI unit) type

External appearance of M (fixed SI unit) type

Dimensional drawing 3 of GS40 Series

Dimensional drawing 3 of GS40 Series

Dimensional drawing of M5 type

Dimensional drawing of M5 type

Dimensional drawing of R type

Dimensional drawing of R type

Notes

Wiring

  • * 1Do not wire when the power is on. If it is short-circuited, the built-in microcomputer will be damaged.
  • * 2If the black wire (output wire) touches the power supply or the circuit is shorted, the built-in output transistor will be burned, causing malfunction.
  • * 3Do not apply pulling force to the power cord. Doing so may result in breakage.
  • * 4Maximum load current is 80 mA. It can be used within the range of 80 mA.
Internal Circuit and Connection

Internal Circuit and Connection

  • Brown wire: Connect the wire to the positive (+) side of the DC power supply to operate the switch.
  • Black wire: Since it is the output of the switch, connect it to the input terminal of the PLC or a load such as a DC relay.
  • Blue wire: Connect the wire to the negative (-) side of the DC power supply to operate the switch.
Wiring examples for relays, resistant loads, etc.

Wiring examples for relays, resistant loads, etc.

  • D1: Reverse connection protection diode
  • D2: Surge suppressor (Surge absorption diode)
  • D3: Surge suppressor (Surge absorption diode)
  • Tr: Output transistor

Mounting/Piping

  • * 1The mounting direction can be horizontal or vertical.
  • * 2The main body must be kept holding when handling the product.
  • * 3Dropping or hitting should be avoided. If an excessive impact is applied, the inside of the switch will be damaged.
  • * 4When mounting on a pipe, apply a wrench to the width across flats for R thread types and the square part on the bottom of the body for M5 types and turn the wrench. If stress is applied to the upper part of the body or resin case, internal parts will be stressed and damaged.
  • * 5Touching the LCD display should be avoided. Touching the LCD display during operation may cause malfunction or damage to internal parts due to the influence of static electricity.

Pressure setting

Name of each part of GS40 Series

Name of each part of GS40 Series

  • * 1How to set the pressure switch: While pressing the push button (1) SET, turn the pressure setting trimmer (3) P.SET to display the set pressure on the pressure display plate (4) LCD. (The set pressure is high for clockwise rotation and low for counterclockwise rotation.) After setting the pressure, press the push button (1) SET to display the line side pressure on the pressure display plate (4) LCD.
  • * 2Alarm display: The ↓ on the LCD flashes within +10% of the pressure setting value of the pressure switch to inform that the set pressure is approaching. When the line pressure falls below the set pressure, (2) the ALM LED (red) lights up and the switch turns on.
  • * 3It can be used within the maximum operating pressure range. If a pressure higher than the maximum operating pressure is applied, the LCD display will show "“OF" and the product cannot be used. In that case, reset the pressure and power supply once.

Operating environment

  • * 1It cannot be used in a place where water or oil is scattered. Since it is an open type structure, if water or oil gets inside, the electric circuit will corrode, resulting in malfunction or damage.
  • * 2It may be affected by induction noise from piping or noise from power line or high voltage line. As it may cause malfunction or damage to the switch, take measures such as grounding the pipe for inductive noise from the pipe or keeping it away from noise on power lines and high-voltage lines.
  • * 3Operating fluids are dedicated for air and inert gas. Fluids cannot be used.
  • * 4It must not be used in an atmosphere of flammable liquid or flammable gas. Since it is not explosion proof, it may cause an explosion hazard.
Part Number
GS40-01
GS40-01-M
GS40-01-M-X202
GS40-01-X202
GS40-02
GS40-02-M
GS40-02-M-X202
GS40-02-X202
GS40-M5
GS40-M5-M
GS40-M5-M-X202
GS40-M5-X202
GS40-M5B
GS40-M5B-M
GS40-M5B-M-X202
GS40-M5B-X202
Part NumberMinimum order quantityVolume DiscountDays to ShipPipe Port Type Plumbing Thread Type Plumbing Thread Nominal Unit Specifications Bracket Lead Wire
1 Piece(s) 20 Day(s) [Threads] Male thread[Rc (R)] R[1/8] 1/8With unit conversion functionNone0.6 m
1 Piece(s) 20 Day(s) [Threads] Male thread[Rc (R)] R[1/8] 1/8SI unit (MPa) fixedNone0.6 m
1 Piece(s) 31 Day(s) [Threads] Male thread[Rc (R)] R[1/8] 1/8SI unit (MPa) fixedNone5 m
1 Piece(s) 31 Day(s) [Threads] Male thread[Rc (R)] R[1/8] 1/8With unit conversion functionNone5 m
1 Piece(s) 20 Day(s) [Threads] Male thread[Rc (R)] R[1/4] 1/4With unit conversion functionNone0.6 m
1 Piece(s) 20 Day(s) [Threads] Male thread[Rc (R)] R[1/4] 1/4SI unit (MPa) fixedNone0.6 m
1 Piece(s) 31 Day(s) [Threads] Male thread[Rc (R)] R[1/4] 1/4SI unit (MPa) fixedNone5 m
1 Piece(s) 31 Day(s) [Threads] Male thread[Rc (R)] R[1/4] 1/4With unit conversion functionNone5 m
1 Piece(s) 20 Day(s) Female ThreadMM5x0.8With unit conversion functionNone0.6 m
1 Piece(s) 15 Day(s) Female ThreadMM5x0.8SI unit (MPa) fixedNone0.6 m
1 Piece(s) 15 Day(s) Female ThreadMM5x0.8SI unit (MPa) fixedNone5 m
1 Piece(s) 15 Day(s) Female ThreadMM5x0.8With unit conversion functionNone5 m
1 Piece(s) 31 Day(s) Female ThreadMM5x0.8With unit conversion functionYes0.6 m
1 Piece(s) 31 Day(s) Female ThreadMM5x0.8SI unit (MPa) fixedYes0.6 m
1 Piece(s) 15 Day(s) Female ThreadMM5x0.8SI unit (MPa) fixedYes5 m
1 Piece(s) 31 Day(s) Female ThreadMM5x0.8With unit conversion functionYes5 m

Loading...

  1. 1

Basic Information

Type Pressure Switch Fluid Type Air Sensor, Monitor Structure Integrated shape
Output Method Switch Fluid Characteristics Inert Pressure Type Standard
Operating Temperature Range(°C) -5::60 Number of Input Points 1 Number of Output Points 1
Power Supply Type DC Power Supply Voltage(V) 24 Mounting Holes No
Display Digital Drive Component Analog Lamp Presence