(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Pembayaran dengan kartu kredit untuk sementara tidak tersedia karena kendala sistem. Sementara waktu Anda dapat meggunakan metode Pembayaran di Muka atau QRIS. Untuk informasi lebih lanjut, silakan hubungi Customer Service : TEL: 021-8984-0008 E-mail: cs@misumi.co.id. WA: 08118984008. Kami mohon maaf atas ketidaknyamanan yang terjadi.
    Credit card payments are temporarily unavailable due to system issues. Meanwhile, you can use the Advance Payment method or QRIS. For further information, please contact Customer Service: TEL: 021-8984-0008 E-mail: cs@misumi.co.id. WA: 08118984008. We apologize for any inconvenience caused.
  • Sehubungan dengan adanya Peraturan Baru Kementerian Perdagangan No.36 Tahun 2023 tentang Pembatasan Impor Barang, MISUMI Indonesia melakukan tindakan pencegahan. Lihat informasi detailnya di sini
    Due to New Regulation of Ministry Of Trade No.36 of 2023 concerning retrictions on imports of goods, MISUMI Indonesia do precautions measure. See detail information here
  • Nomor telepon alternatif Kontak Layanan Pelanggan : 021-29182911| 021-29182991 | 021-29182997 | 021-29182998
    Alternative telephone number Contact Customer Service: 021-29182911 | 021-29182991 | 021-29182997 | 021-29182998

Thermo-Dryer, Refrigerant R134a (HFC) IDH4/IDH6/IDHA4/IDHA6

Thermo-Dryer, Refrigerant R134a (HFC) IDH4/IDH6/IDHA4/IDHA6

Thermo-dryer is able to provide compressed air under the same conditions and with the same quality regardless of the season.
[Features]
· Stable supply of temperature- and pressure-controlled dry clean air.
· Power supply can be used all over the world.
· Compact and space saving.
· Can be installed close to a wall.
· Power supply voltage: Single-phase 100/200/230 V AC (50/60 Hz).
· RoHS compliant.

(i)Caution

  • ■ SMC Product Line
    Webpages for products currently without individual pages on this site will be released on an ad-hoc basis.

    ■ Products Planned for Online Release
    Air cylinder-related product pages will be released on this site on an ad-hoc basis.
    CQ2/MG types, etc., are already available.
    *Vacuum equipment, FRLs, solenoid valves, etc., will also be released on dedicated pages on this site on an ad-hoc basis.
    *The information above is correct as of December 2018.
  • See catalog for specification details.
  • Product images may be representative images. Refer to the manufacturer's catalog for shape details.

PDF

Part Number

Configured Part Number is shown.

IDHA4-23B-E

Refrigerant R134a (HFC) IDH□ Series Specifications

IDH□ Series external appearance

IDH□ Series external appearance

Size

  • Rated air flow capacity: 400L/min (ANR)
  • Air compressor size: 3.7 kW
  • Rated air flow capacity: 600 L/min (ANR)
  • Air compressor size: 5.5 kW

Structure Principle Diagram (Air/Refrigerant Circuit)

Structure Principle Diagram (Air/Refrigerant Circuit)

Structure Principle Diagram (Air/Refrigerant Circuit)

Pneumatic Circuit

Hot and humid air entering this product is cooled down by the cooler. The moisture condensed at this time is separated by the drain separator and exhausted automatically. The pressure of the dry air is adjusted by the regulator, and oil mist and solid particles are separated by the micro mist separator with pre-filter and super mist separator. The temperature of the dry and high-purity air is adjusted by the heater, and the air is supplied to the outlet side.

*The type without filter is not applicable.

Refrigerant Circuit

The HFC gas contained in the refrigerant circuit is compressed by the compressor, and cooled and liquefied by the condenser. When passing through the capillary tube, the HFC gas is regulated and its temperature decreases. While passing through the cooler part, it evaporates rapidly, taking the heat from the compressed air, and is sucked in by the compressor. The capacity regulating valve opens when the compressed air has been cooled sufficiently, and prevents condensed water from being frozen by excessive cooling.

Standard Specifications

SpecificationsModel
IDH4-10□IDH4-20□IDHA4-23□IDH6-10□IDH6-20□IDHA6-23□
Operating range*3Applicable fluidCompressed Air
Air flow capacity*1100 to 500 L/min (ANR)200 to 800 L/min (ANR)
Inlet air temperature5 to 40°C
Inlet air pressure0.3 to 1.0 MPa
Ambient temperature15 to 35°C (Relative humidity 85% or less)
Outlet air temperature adjustment range*215 to 30°C
Outlet air set pressure range0.15 to 0.85 MPa
(The inlet air pressure should be at least 0.15 MPa higher than the outlet air pressure.)
Rated conditionsAir flow capacity400 L/min (ANR)600 L/min (ANR)
Inlet air pressure0.7 MPa
Inlet air temperature35°C
Ambient temperature30°C
Outlet air set temperature30°C
Rated performance*4Outlet air pressure dew point10°C
Outlet air temperature stability*5±0.1°C (This may vary depending on the conditions.)
Outlet air temperature display accuracy±0.5°C (including accuracy of the sensor)
Electric specificationsPower supply*6Single-phase 100 V AC
(50/60 Hz)
Single-phase 200 V AC
(50/60 Hz)
Single-phase 230 V AC
(50/60 Hz)
Single-phase 100 V AC
(50/60 Hz)
Single-phase 200 V AC
(50/60 Hz)
Single-phase 230 V AC
(50/60 Hz)
Operating current4.2 A2.1 A2.1 A9.4 A4.8 A4.8 A
Earth leakage breaker capacity10 A5 A5 A15 A10 A10 A
Compressor input180/200 W 50/60 Hz385/440 W 50/60 Hz
Heater input220 W420 W
Built-in filter specifications*7Nominal filtration rating0.01 μm (99.9% filtration efficiency)
Cleanliness of the filter outlet sideParticles of 0.3 μm or more: 3.5 particles/L (ANR) or less
Temperature control methodHeater operation, PID control
Refrigerant type / Refrigerant chargeR134a / 0.14 kgR134a / 0.26 kg
Noise level (reference value)*852 dB (A)55 dB (A)
Weight26 kg37 kg
Applicable drain tube O.D.10 mm
Coating colorBody panel: urban white 1, Base: urban gray 2
Compliant standardsCE marked

*1: ANR is the value at 20°C, atmospheric pressure and relative humidity 65%.
*2: About 10 minutes are required until the temperature becomes stable after setting the temperature.
*3: The upper limit of the settable outlet air temperature varies depending on the conditions even within the operating range. Be sure to read the selection document before selecting the models.
*4: The rated performance is the performance when the operation of each part is stable without fluctuations in operating conditions and power supply. If the air flow capacity is beyond its specified range or if the air flows intermittently, the outlet air temperature range or temperature stability may not be satisfied. (If this happens, install a purge line and flow the compressed air continuously.)
*5: When the outlet air temperature is set in the range of the ambient temperature ±5°C.
*6: Keep the voltage within -5 to +10% of the rated voltage. If there is voltage fluctuation, the outlet air temperature stability may decrease. So if highly accurate temperature adjustment is required, use a stable power supply to make the voltage fluctuation smaller.
*7: The specification changes depending on the cleanliness of the inlet side air. It may take time until the cleanliness of the filter outlet side air stabilizes immediately after start of operation. The filter performance only applies to the built-in type filter.
*8: 1 m in front of the product, 1 m in height, without load, stable conditions.

Output Signal

Output signal timing chart

Output signal timing chart

DescriptionTerminal No.Description of operationContact capacityMinimum load
Operating signal N.O. (a-contact)1-2Close after 10 minutes of operationResistance load 2 A
Inductive load 80 VA
Lamp load 100 W
5 V DC 2 mA
Error signal N.C. (b contact)3-4Open at an emergency stop or set temperature error
Error signal N.O. (a-contact)4-5Close at an emergency stop or set temperature error

*1: The operation can be started or restarted (manually) by the operation stop switch mounted on the thermo-dryer or a remote switch prepared by the user.
*2: When an emergency stop is generated 5 times in an hour or the heater protection equipment (thermostat) is activated, the emergency stop status will be held. In this case, the dryer can be restarted by the reset operation using the switch stated in *1.

Dimensions

 

(Unit: mm)

 

Dimensional drawing: IDH□4

Dimensional drawing: IDH□4

 

(Unit: mm)

 

Dimensional drawing: IDH□6

Dimensional drawing: IDH□6

Condensed Water Calculation

Condensed water calculation chart

Condensed water calculation chart

How to calculate the amount of condensed water

Example: To obtain the amount of condensed water when the pressure is applied to air up to 0.7 MPa with an air compressor, then cooled down to 25°C, with an ambient temperature of 30°C and a relative humidity of 60%.

  • 1. Trace the arrow mark from point A at an ambient temperature of 30°C to obtain intersection B on the curved line for the relative humidity of 60%.
  • 2. Trace the arrow mark from intersection B to obtain intersection D on the pressure characteristic line for 0.7 MPa.
  • 3. Trace the arrow mark from intersection D to obtain intersection E.
  • 4. Intersection E is the dew point under pressure of 0.7 MPa with an ambient temperature of 30°C and a relative humidity of 60%. The value for E is 62°C.
  • 5. Trace intersection E upward, and trace from intersection D leftward to obtain intersection C.
  • 6. Intersection C is the amount of moisture included in the compressed air of 1 m3 at 0.7 MPa and a pressure dew point of 62°C. The amount of moisture is 18.2 g/m3.
  • 7. Trace the arrow mark, starting from F for a cooling temperature of 25°C (pressure dew point of 25°C) to obtain intersection G on the pressure characteristic line for 0.7 MPa.
  • 8. From intersection G, trace the arrow mark to obtain intersection H on the vertical axis.
  • 9. Intersection H is the amount of moisture included in the compressed air of 1 m3 at 0.7 MPa and a pressure dew point of 25°C. The amount of moisture is 3 g/m3.
  • 10. Therefore, the amount of condensed water is as follows:

(Per 1 m3) Amount of moisture at intersection C - amount of moisture at intersection H = amount of condensed water or 18.2 - 3 = 15.2 g/m3

Dew Point Conversion Chart

Dew point conversion chart

Dew point conversion chart

How to read the dew point conversion chart

(Example) To obtain the atmospheric pressure dew point at a pressure dew point of 10°C and a pressure of 0.7 MPa.

  • 1. Trace the arrow mark starting from point A at a pressure dew point of 10°C to obtain intersection B on the pressure characteristic line for 0.7 MPa.
  • 2. Trace the arrow mark starting from point B to obtain intersection C at the dew point under atmospheric pressure.
  • 3. Intersection C is the conversion value -17°C under the atmospheric pressure dew point.

Precautions

Avoid installing in the following locations

  • Avoid locations in direct contact with wind or rain and locations with high humidity. (Relative humidity 85% or more)
  • *Avoid exposure to direct sunlight.
  • *Avoid locations that contain large amounts of dust, corrosive gases, or flammable gases.
  • *Avoid locations with poor ventilation and high temperatures.
  • *Avoid locations where there is strong magnetic noise (strong electric field, strong magnetic field, or surge).
  • *Avoid locations or conditions where static electricity is discharged to the body.
  • *Avoid locations where the temperature rapidly changes.
  • *Avoid locations where the dryer is likely to be damaged by lightning.
  • *Avoid locations with an altitude of 2,000 m or higher. (This does not apply to storage and transportation.)
  • *Avoid locations where the dryer could draw in high-temperature air discharged from an air compressor or other dryer.
  • *Avoid locations subject to strong impact or vibration.
  • *Avoid conditions where an external force or weight that could deform the dryer is applied.
  • *Avoid locations where the drain could freeze.
  • *Avoid installation on machines for transportation, such as vehicles and ships.
  • *Avoid locations subject to sudden changes in pressure or flow rate.

Additional Precautions

*See the manufacturer's catalog for product information other than the above.

Part Number
IDHA4-23B-E
Part NumberMinimum order quantityVolume DiscountDays to Ship
1 Piece(s) 20 Day(s)

Loading...

  1. 1

Basic Information

Type Dryer Method Refrigerating type (air-cooling specification) Shape Standard
Air Inlet Flow(l/min) 400 Air Inlet Flow Rate [Distinction](l/min) ~400 Outlet Open Air Pressure Dew-point(℃) 10
Supply Side, Connection Type Rc Air Compressor Size(kW) 3.7 Inlet Air Temperature(℃) 35
Inlet Air Pressure(MPa) 0.7 Supply Side, Plumbing Thread Nominal 1/2 Control Side, Connection Type Rc
Control Side, Plumbing Thread Nominal 1/2 Power Supply Voltage Single-phase 230 V AC 50/60 Hz Auto drain Auto drain (normally closed)
Filter None

Please check the type/dimensions/specifications of the part IDHA4-23B-E in the Thermo-Dryer, Refrigerant R134a (HFC) IDH4/IDH6/IDHA4/IDHA6 series.

Tech Support