(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Pembayaran dengan kartu kredit untuk sementara tidak tersedia karena kendala sistem. Sementara waktu Anda dapat meggunakan metode Pembayaran di Muka atau QRIS. Untuk informasi lebih lanjut, silakan hubungi Customer Service : TEL: 021-8984-0008 E-mail: cs@misumi.co.id. WA: 08118984008. Kami mohon maaf atas ketidaknyamanan yang terjadi.
    Credit card payments are temporarily unavailable due to system issues. Meanwhile, you can use the Advance Payment method or QRIS. For further information, please contact Customer Service: TEL: 021-8984-0008 E-mail: cs@misumi.co.id. WA: 08118984008. We apologize for any inconvenience caused.
  • Sehubungan dengan adanya Peraturan Baru Kementerian Perdagangan No.36 Tahun 2023 tentang Pembatasan Impor Barang, MISUMI Indonesia melakukan tindakan pencegahan. Lihat informasi detailnya di sini
    Due to New Regulation of Ministry Of Trade No.36 of 2023 concerning retrictions on imports of goods, MISUMI Indonesia do precautions measure. See detail information here
  • Nomor telepon alternatif Kontak Layanan Pelanggan : 021-29182911| 021-29182991 | 021-29182997 | 021-29182998
    Alternative telephone number Contact Customer Service: 021-29182911 | 021-29182991 | 021-29182997 | 021-29182998

Power Supply SPD, Class II/III, LGL Series

Power Supply SPD, Class II/III, LGL Series

SPD for power supply with built-in disconnection device with no follow current and excellent response performance.
[Features]
・ Response speed is 3 nsec or less, excellent response, no follow current
・ Maximum electric discharge machining current (Imax) protects the power supply from 20 kA, 40 kA (8/20 μs), lightning surge/ switching surge, multiple-lightning
・ With safety function even when it deteriorates
・ Built-in disconnecting device, visual inspection from transparent inspection window
・ DIN rail mounting, screw mounting supported
・ Easy and reliable inspection and attachment/detachment mechanism
・ Circuit insulation resistance measurement (insulation resistance test) available
・ Can be used for connection between ground electrodes
[Applications]
・ Protection of low-voltage distribution board (power distribution board) and low-voltage power supply circuit

PDF

Japanese Only

Part Number

Configured Part Number is shown.

 
Part Number
GL-L1F
GL-L2F
LT-L1F
LT-L2F
LT-L4F
Part NumberMinimum order quantityVolume DiscountDays to ShipRoHSVoltage Dimension depth
(mm)
Maximum Continuous Operational Voltage Nominal Discharge Current (8/20 μs) Maximum Discharge Current (8/20 μs) Voltage protection level Voltage when starting operations
1 Piece(s) 12 Day(s) or more -100V61.5AC110V10kA20kA700V or less250V±12%
1 Piece(s) 12 Day(s) or more -200V61.5AC230V10kA20kA1200V or less500V±12%
1 Piece(s) 14 Day(s) or more 10100V61.5AC110V20kA40kA800V or less220V±10%
1 Piece(s) 12 Day(s) or more -200V61.5AC230V20kA40kA1300V or less440 V±10%
1 Piece(s) 16 Day(s) or more 10400V70AC440V20kA40kA2500V or less1000V±10%

Loading...

  1. 1

Basic Information

Application Power Supply Type Single pole type Mounting Method Crimp terminal attached
Class, category Class II / Class III Dimension vertical(mm) 96 Dimension width(mm) 25