Electromagnetic Switch Without Case

Electromagnetic Switch Without Case

Separated into series according to the rated capacity for motor operation control. A version that includes a case cover is also available.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

MUF50HB110

 
Part Number
MUF50HB110
Part NumberVolume DiscountDays to ShipMotor capacity 400 to 440-VAC class
(kW/A)
Motor Capacity VAC 200–220 Class
(kW/A)
Coil rated voltage
(V)
Number of Poles Auxiliary Contact Dimension length
(mm)
Dimension width
(mm)
Dimension height
(mm)
With thermal relay Auxiliary contact rated current used AC-15 220 V
(A)
Rated current used AC-3 220 V
(A)
Applicable motor type Applicable motor capacity
(kW)
Durability Mechanical
(x10K times)
Durability Electrical (AC-3)
(x10K times)
Durability Opening and closing frequency
(Times/Hour)
After adding coil capacity
(VA)
After adding coil capacity
(VA)
After coil consumption power is turned on
(W)
After adding coil current
(mA)
Ambient Operating Temperature Min
(°C)
Ambient Operating Temperature Max
(°C)
Min relative humidity
(%)
Max relative humidity
(%)
11 Day(s) or more 11/2211/42AC200Three-Phase2a2b170.598118.5350--50010012002142210110-5404585

Loading...

  1. 1

Basic Information

Operating Method Irreversible

Please check the type/dimensions/specifications of the part MUF50HB110 in the Electromagnetic Switch Without Case series.

Products like this...

Part Number
MUF10-4HB022
MUF10-5HB001
MUF10-5HB002
MUF50HB6110
MUF65HB150
MUF65HB6150
Part NumberVolume DiscountDays to ShipMotor capacity 400 to 440-VAC class
(kW/A)
Motor Capacity VAC 200–220 Class
(kW/A)
Coil rated voltage
(V)
Number of Poles Auxiliary Contact Dimension length
(mm)
Dimension width
(mm)
Dimension height
(mm)
With thermal relay Auxiliary contact rated current used AC-15 220 V
(A)
Rated current used AC-3 220 V
(A)
Applicable motor type Applicable motor capacity
(kW)
Durability Mechanical
(x10K times)
Durability Electrical (AC-3)
(x10K times)
Durability Opening and closing frequency
(Times/Hour)
After adding coil capacity
(VA)
After adding coil capacity
(VA)
After coil consumption power is turned on
(W)
After adding coil current
(mA)
Ambient Operating Temperature Min
(°C)
Ambient Operating Temperature Max
(°C)
Min relative humidity
(%)
Max relative humidity
(%)
11 Day(s) or more 2.2/52.2/9AC200Three-Phase1a98.54381313--500100120046102.750-5404585
30 Day(s) or more --200 AC-1a1b77.55398.5HRD010B313Three-phase 220 V0.15001001,20046102.750-5404585
20 Day(s) or more 0.2/0.60.2/1.2AC200Three-Phase1a1b98.55377.5313--500100120046102.750-5404585
30 Day(s) or more --100 AC-2a2b118.598170.5HRE75DG350Independent 100 V coil115001001,200-----5404585
13 Day(s) or more 15/3015/56AC200Three-Phase2a2b170.598118.5365--50010012002142210110-5404585
30 Day(s) or more --100 AC-2a2b118.598170.5HRE75DG365Independent 100 V coil155001001,200-----5404585