Electromagnetic Switch With Case

Part Number

Configured Part Number is shown.

 
Part Number
MUE80H190
MUE100H220
MUE180H450
MUF7H001
MUF7H002
MUF7H004
MUF7H007
MUF7H011
MUF7H015
MUF7H601
MUF7H602
MUF7H604
MUF7H607
MUF7H611
MUF7H615
MUF10-4H022
MUF10-5H001
MUF10-5H002
MUF10-5H004
MUF10-5H007
MUF10-5H011
MUF10-5H015
MUF10-5H022
MUF10-5H104
MUF10-5H622
MUF18H037
MUF18H107
MUF18H637
MUF20H037
MUF25H055
MUF35H075
MUF50H110
MUF50H6110
MUF65H150
MUF65H6150
MUF300H750
MUF400H1100
Part NumberVolume DiscountDays to ShipMotor capacity 400 to 440-VAC class
(kW/A)
Motor Capacity VAC 200–220 Class
(kW/A)
Coil rated voltage
(V)
Number of Poles Auxiliary Contact Representative Standard Dimension length
(mm)
Dimension width
(mm)
Dimension height
(mm)
With thermal relay Auxiliary contact rated current used AC-15 220 V
(A)
Rated current used AC-3 220 V
(A)
Applicable motor type Applicable motor capacity
(kW)
Durability Mechanical
(x10K times)
Durability Electrical (AC-3)
(x10K times)
Durability Opening and closing frequency
(Times/Hour)
After adding coil capacity
(VA)
After adding coil capacity
(VA)
After coil consumption power is turned on
(W)
After adding coil current
(mA)
Ambient Operating Temperature Min
(°C)
Ambient Operating Temperature Max
(°C)
Min relative humidity
(%)
Max relative humidity
(%)
20 Day(s) or more -19/67AC200Three-Phase2a2b-375215163380--50010012003003210160-5404585
13 Day(s) or more 22/4222/80AC200Three-Phase2a2b-375215163393--50010012003003210160-5404585
30 Day(s) or more --220 AC---198260500HRE180DG-180Three-phase 220 V45-----------
30 Day(s) or more --220 AC-1aPSE9180153HRD010B311Three-phase 220 V0.1--------5404585
20 Day(s) or more 0.2/0.60.2/1.2AC200Three-Phase1aPSE1538091311--500100120046102.750-5404585
11 Day(s) or more 0.4/1.20.4/2.2AC200Three-Phase1aPSE1538091311--500100120046102.750-5404585
11 Day(s) or more 0.75/1.70.75/3.6AC200Three-Phase1aPSE1538091311--500100120046102.750-5404585
20 Day(s) or more -1.1/5AC200Three-Phase1aPSE1538091311--500100120046102.750-5404585
11 Day(s) or more 1.5/3.61.5/6.7AC200Three-Phase1aPSE1538091311--500100120046102.750-5404585
30 Day(s) or more --100 AC-1a-9180153HRD010B311Independent 100 V coil0.1--------5404585
20 Day(s) or more 0.2/0.60.2/1.2AC100Three-Phase1aPSE1538091311--500100120046102.750-5404585
20 Day(s) or more 0.4/1.20.4/2.2AC100Three-Phase1aPSE1538091311--500100120046102.7100-5404585
20 Day(s) or more 0.75/1.70.75/3.6AC100Three-Phase1aPSE1538091311--500100120046102.7100-5404585
30 Day(s) or more --100 AC-1a-9180153HRD010B311Independent 100 V coil1.1--------5404585
20 Day(s) or more 1.5/3.61.5/6.7AC100Three-Phase1aPSE1538091311--500100120046102.7100-5404585
11 Day(s) or more 2.2/52.2/9AC200Three-Phase1aPSE1538091313--500100120046102.750-5404585
30 Day(s) or more --220 AC-1a1bPSE9180153HRD010B313Three-phase 220 V0.1--------5404585
20 Day(s) or more 0.2/0.60.2/1.2AC200Three-Phase1a1bPSE1538091313--500100120046102.750-5404585
20 Day(s) or more 0.4/1.20.4/2.2AC200Three-Phase1a1bPSE1538091313--500100120046102.750-5404585
20 Day(s) or more 0.75/1.70.75/3.6AC200Three-Phase1a1bPSE1538091313--500100120046102.750-5404585
30 Day(s) or more --220 AC-1a1bPSE9180153HRD010B313Three-phase 220 V1.1--------5404585
20 Day(s) or more 1.5/3.61.5/6.7AC200Three-Phase1a1bPSE1538091313--500100120046102.750-5404585
20 Day(s) or more 2.2/52.2/9AC200Three-Phase1a1bPSE1538091313--500100120046102.750-5404585
30 Day(s) or more --110 AC-1a1bPSE9180153HRD010B313Single-phase 110 V0.4--------5404585
30 Day(s) or more --100 AC-1a1b-9180153HRD010B313Independent 100 V coil2.2--------5404585
11 Day(s) or more 3.7/6.73.7/15AC200Three-Phase1a1bPSE1609099220--500100120057123.360-5404585
30 Day(s) or more --110 AC-1a1bPSE99-160HRD018B220Single-phase 110 V0.75--------5404585
30 Day(s) or more --100 AC-1a1b-99-160HRD018B220Independent 100 V coil3.7--------5404585
15 Day(s) or more 3.7/6.73.7/15AC200Three-Phase1a1bPSE1609099320--10001001200708.42.443-5404585
11 Day(s) or more 5.5/125.5/22AC200Three-Phase2a2bPSE231138129.5326--10001001200140145.270-5404585
11 Day(s) or more 7.5/157.5/30AC200Three-Phase2a2bPSE231138129.5335--10001001200140145.270-5404585
15 Day(s) or more 11/2211/42AC200Three-Phase2a2bPSE300163146350--50010012002142210110-5404585
30 Day(s) or more --100 AC-2a2b-146163300HRE75DG350Independent 100 V coil11--------5404585
13 Day(s) or more 15/3015/56AC200Three-Phase2a2b-300163146365--50010012002142210110-5404585
30 Day(s) or more --100 AC-2a2b-146163300HRE75DG365Independent 100 V coil15--------5404585
30 Day(s) or more --220 AC-2a2b-284314674HRD018D3300Three-phase 220 V55 to 75--------5404585
30 Day(s) or more --220 AC-2a2b-284314674HRD018D3400Three-phase 220 V90 to 110--------5404585

Loading...

  1. 1

Basic Information

Operating Method Irreversible with Case

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:021-8990-4102 / FAX:021-8990-5803
8:30am - 5:30pm (Monday - Friday)