Earth Leakage Circuit Breakers (ELCB) NV-CV Series

NV63-CV Specifications

Type NameNV63-CV
Rated current In
standard ambient temperature 40°C A
60
Number of contacts23
Phase wire systemø 1, 2 W3 ø 3 W,
1 ø 3 W,
1 ø 2 W
Rated operating voltage Ue VAC100 to 240100-440
High-speed

type
Rated sensitivity current mA30(15) 30
(100/200/500 switch)
Maximum operating time sat I △n0.1
at 5I △n0.04
Time-delay

type
Rated sensitivity current mA-
Maximum operating time s-
Inertia dead time s or more-
Electrical leakage display methodMechanical button
Rated
short
circuit
breaking
capacity
kA


JIS C 8201-2-2 Ann. 1
JIS C 8201-2-2 Ann. 2
IEC 60947-2 2nd.ed.
(Icu/Ics)
AC440 V-2.5/2.5
415 V-2.5/2.5
400 V-5/5
230 V7.5/7.5
200 V7.5/7.5
100 V7.5/7.5

NV63-CV Dimensional Outline Drawing

Front Surface Type

Front Surface Type

Back Surface Type

Back Surface Type

Embedded Type

Embedded Type

Inserted Type

Inserted Type
  • Note: See the catalog for details on other products.
Part Number
NV63-CV 3P 60A 100-440V 1.2.500MA
NV63-CV 3P 60A 100-440V 30MA
NV125-CV 3P 60A 100-440V 1.2.500MA
NV125-CV 3P 75A 100-440V 1.2.500MA
NV125-CV 3P 125A 100-440V 1.2.500MA
NV250-CV 3P 125A 100-440V 1.2.500MA
NV250-CV 3P 150A 100-440V 1.2.500MA
NV250-CV 3P 175A 100-440V 1.2.500MA
NV250-CV 3P 200A 100-440V 1.2.500MA
NV250-CV 3P 225A 100-440V 1.2.500MA
Part NumberMinimum order quantityVolume DiscountDays to ShipAmpere frame AF Rated block capacity AC 100 V
(kA)
Rated block capacity AC 200 V
(kA)
Rated block capacity AC 400 V
(kA)
Rated Current
(A)
rate sensitivity current
(mA)
Dimension height
(mm)
Dimension width
(mm)
Dimension depth
(mm)
1 Piece(s) Same day 60AF7.57.5560100· 200· 500 switch1307590
1 Piece(s) Same day 60AF7.57.5560301307590
1 Piece(s) Same day [100AF to 199AF] 100AF30301060100· 200· 500 switch1309090
1 Piece(s) Same day [100AF to 199AF] 100AF30301075100· 200· 500 switch1309090
1 Piece(s) Same day [100AF to 199AF] 125AF303010125100· 200· 500 switch1309090
1 Piece(s) Quote [200AF to 399AF] 225AF363625125100· 200· 500 switch16510592
1 Piece(s) Quote [200AF to 399AF] 225AF363625150100· 200· 500 switch16510592
1 Piece(s) Quote [200AF to 399AF] 225AF363625175100· 200· 500 switch16510592
1 Piece(s) Quote [200AF to 399AF] 225AF363625200100· 200· 500 switch16510592
1 Piece(s) Quote [200AF to 399AF] 225AF363625225100· 200· 500 switch16510592

Loading...

  1. 1
 

Basic Information

Number of Poles 3 Rated Operating Voltage(V) AC100 to 440 Mounting Method Fasten With Screws
Connection Method Surface form Type Economical Products Specifications High Harmonics/Surge Compatible Table