(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Pembayaran dengan kartu kredit untuk sementara tidak tersedia karena kendala sistem. Sementara waktu Anda dapat meggunakan metode Pembayaran di Muka atau QRIS. Untuk informasi lebih lanjut, silakan hubungi Customer Service : TEL: 021-8984-0008 E-mail: cs@misumi.co.id. WA: 08118984008. Kami mohon maaf atas ketidaknyamanan yang terjadi.
    Credit card payments are temporarily unavailable due to system issues. Meanwhile, you can use the Advance Payment method or QRIS. For further information, please contact Customer Service: TEL: 021-8984-0008 E-mail: cs@misumi.co.id. WA: 08118984008. We apologize for any inconvenience caused.
  • Sehubungan dengan adanya Peraturan Baru Kementerian Perdagangan No.36 Tahun 2023 tentang Pembatasan Impor Barang, MISUMI Indonesia melakukan tindakan pencegahan. Lihat informasi detailnya di sini
    Due to New Regulation of Ministry Of Trade No.36 of 2023 concerning retrictions on imports of goods, MISUMI Indonesia do precautions measure. See detail information here
  • Nomor telepon alternatif Kontak Layanan Pelanggan : 021-29182911| 021-29182991 | 021-29182997 | 021-29182998
    Alternative telephone number Contact Customer Service: 021-29182911 | 021-29182991 | 021-29182997 | 021-29182998

Circuit Protectors CP30-BA Series (CP30-BA 1P 1-M 0.5A)

Circuit Protectors CP30-BA Series CP30-BA 1P 1-M 0.5A

[CP30-BA] a combination of advanced breaker technology. Small, high performance circuit protector

PDF

Part Number

Configured Part Number is shown.

CP30-BA 1P 1-M 0.5A

Model CP30-BA Features

What is a Circuit Protector?

  • Mainly used to protect low capacity control circuits, heaters, motors, solenoid valves, transformers, electronic circuits, etc., that cannot be protected with MCCB.
  • Saves space for various control circuits in equipment and control panels, etc.

Circuit Protector Features

Open/close type small terminal cover is standard equipment.

Open/close type small terminal cover is standard equipment.

Open/close type small terminal cover + wire marker sleeve insulation provides good finger protection (IP20 supported from front direction [TÜV-certified]). Added finger protection from the direction of cable insertion.

Open/close type small terminal cover + wire marker sleeve insulation provides good finger protection (IP20 supported from front direction [TÜV-certified]). Added finger protection from the direction of cable insertion.

Can open and close with a single action, making terminal check easy when shipping panels or when performing initial inspection. Easy to check terminals during maintenance.

Can open and close with a single action, making terminal check easy when shipping panels or when performing initial inspection.
Easy to check terminals during maintenance.

Even if the terminal cover is closed, the wire marker sleeve symbol is not hidden and can be checked at a glance.

Even if the terminal cover is closed, the wire marker sleeve symbol is not hidden and can be checked at a glance.

Insulation resistance measurement and energization inspection are possible even when the terminal cover is closed.

Insulation resistance measurement and energization inspection are possible even when the terminal cover is closed.

Type for Both AC and DC Use

Type for both AC and DC use. Can be used as is for circuits not more than 250 V AC and 65 V DC.

Space Saving

  • Compact, with an extremely thin width of 17.5 mm per pole.
  • Greatly contributes to space saving, particularly when using a large quantity.

Model CP30-BA Specifications

ModelCP30-BA
Number of Poles123
Rated current In (A)0.1 0.25 0.3 0.5 1 2 3 5 7 10 15 20 30
Rated
breaking
current



(kA)
UL 1077
CSA C22.2
No.235
Rated voltageV AC250
V AC65125-
AC2.5 kA at 250 V
DC2.5 kA at 65 V2.5 kA at 125 V-
IEC 60934
EN 60934
GB 17701 (*3)
(Icn)
Rated insulation voltage
Ui V
250
AC2.5 kA at 230 V
DC2.5 kA at 60 V2.5 kA at 120 V-
JIS C 4610
(Icn)
Rated insulation voltage
Ui V
250
AC2.5 kA at 230 V
DC2.5 kA at 60 V2.5 kA at 120 V-
IEC 60947-2
EN 60947-2
JIS C 8201-2-1
Ann.1(Icu/Ics)
Rated insulation voltage
Ui V
250
AC2.5/2.5 kA at 230 V
DC 2.5/2.5 kA at 120 V-
AC/DC common useCommon use- (*1)
Operating characteristicsInstantaneous type (I); medium-speed type (M), (MD); low-speed type (S),
(SD); high-speed type (F) (*2)
Standard equipmentIEC 35-mm rail mounting tool

(*1) 3-pole products are dedicated to AC use.
(*2) Please inquire regarding operating characteristics for those other than the instantaneous type (I); medium-speed type (M), (MD); low-speed type (S), (SD); and high-speed type (F).
(*3) CP30-BA only.

Part Number
CP30-BA 1P 1-M 0.5A
Part NumberMinimum order quantityVolume DiscountDays to ShipRoHSRated block capacity When DC 60 V
(kA)
Rated block capacity voltage conditions besides AC 250 V/DC 60 V Number of Poles Rated Voltage Rated Current
(A)
Operating properties Warning output presence Representative Standard Dimension width
(mm)
Inertial delay included Connection Method P1 internal circuit specification P2 internal circuit specification P3 internal circuit specification Rated block capacity when DC 120 V
(kA)
Rated block capacity when AC 230 V
(kA)
Rated block capacity when DC 65 V
(kA)
Rated block capacity When DC 125 V
(kA)
1 Piece(s) Same day --Available1-poleAC250V / DC65V0.5Medium speedNAPSE / CE / UL / TUV / CCC / CSA17.5×ScrewSeries shape----2.5-

Loading...

  1. 1
 

Basic Information

Rated block capacity When AC 250 V(kA) 2.5kA Polarity presence NA Dimension height(mm) 73
Dimension depth(mm) 65

Please check the type/dimensions/specifications of the part CP30-BA 1P 1-M 0.5A in the Circuit Protectors CP30-BA Series series.

Products like this...

Part Number
CP30-BA 1P 1-F 10A
CP30-BA 1P 1-F 15A
CP30-BA 1P 1-F 1A
CP30-BA 1P 1-M 10A
CP30-BA 1P 1-M 15A
CP30-BA 1P 1-M 1A
Part NumberMinimum order quantityVolume DiscountDays to ShipRoHSRated block capacity When DC 60 V
(kA)
Rated block capacity voltage conditions besides AC 250 V/DC 60 V Number of Poles Rated Voltage Rated Current
(A)
Operating properties Warning output presence Representative Standard Dimension width
(mm)
Inertial delay included Connection Method P1 internal circuit specification P2 internal circuit specification P3 internal circuit specification Rated block capacity when DC 120 V
(kA)
Rated block capacity when AC 230 V
(kA)
Rated block capacity when DC 65 V
(kA)
Rated block capacity When DC 125 V
(kA)
1 Piece(s) Same day --Available1-poleDC65V / AC250V10High SpeedNAPSE / CE / UL / TUV / CCC / CSA17.5×ScrewSeries shape----2.5-
1 Piece(s) Same day --Available1-poleDC65V / AC250V15High SpeedNAPSE / CE / UL / TUV / CCC / CSA17.5×ScrewSeries shape----2.5-
1 Piece(s) Same day --Available1-poleDC65V / AC250V1High SpeedNAPSE / CE / UL / TUV / CCC / CSA17.5×ScrewSeries shape----2.5-
1 Piece(s) Same day --Available1-poleDC65V / AC250V10Medium speedNAPSE / CE / UL / TUV / CCC / CSA17.5×ScrewSeries shape----2.5-
1 Piece(s) Same day --Available1-poleDC65V / AC250V15Medium speedNAPSE / CE / UL / TUV / CCC / CSA17.5×ScrewSeries shape----2.5-
1 Piece(s) Same day --Available1-poleDC65V / AC250V1Medium speedNAPSE / CE / UL / TUV / CCC / CSA17.5×ScrewSeries shape----2.5-

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:021-8990-4102 / FAX:021-8990-5803
8:30am - 5:30pm (Monday - Friday)