(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Pembayaran dengan kartu kredit untuk sementara tidak tersedia karena kendala sistem. Sementara waktu Anda dapat meggunakan metode Pembayaran di Muka atau QRIS. Untuk informasi lebih lanjut, silakan hubungi Customer Service : TEL: 021-8984-0008 E-mail: cs@misumi.co.id. WA: 08118984008. Kami mohon maaf atas ketidaknyamanan yang terjadi.
    Credit card payments are temporarily unavailable due to system issues. Meanwhile, you can use the Advance Payment method or QRIS. For further information, please contact Customer Service: TEL: 021-8984-0008 E-mail: cs@misumi.co.id. WA: 08118984008. We apologize for any inconvenience caused.
  • Pemberitahuan Jadwal Pemeliharaan : Situs ini akan tidak tersedia dikarenaka jadwal pemeliharaan mulai dari 8:00 21/4/2024 sampai dengan 5:00 pada tanggal 22/4/2024. Kami mohon maaf atas ketidaknyamanan yang terjadi.
    Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 8:00 21/4/2024 to 5:00 (WIB) 22/4/2024. We apologize for the inconvenience.
  • Sehubungan dengan adanya Peraturan Baru Kementerian Perdagangan No.36 Tahun 2023 tentang Pembatasan Impor Barang, MISUMI Indonesia melakukan tindakan pencegahan. Lihat informasi detailnya di sini
    Due to New Regulation of Ministry Of Trade No.36 of 2023 concerning retrictions on imports of goods, MISUMI Indonesia do precautions measure. See detail information here

NBC Series Single-Phase Noise Filter (High Attenuation / 2-Stage Filter / Low-Frequency Attenuation)

NBC Series Single-Phase Noise Filter (High Attenuation / 2-Stage Filter / Low-Frequency Attenuation)

Push-down terminal block 150KHz to 1MHz high attenuation (NBC)

[Features]
· 150kHz-1MHz high attenuation type (2-stage filter).
· Single phase 250V.
· Quick and easy push-down terminal block adoption (patent pending).
· With screw dropout prevention function

PDF

INDEX

Features of NBC series

NBC series

NBC series

150 kHz to 1 MHz high attenuation type (2-stage filter)
Single-phase 250 V
It uses a quick and easy push-down terminal block (With screw fall prevention function)

Ordering information

Ordering information

1 Series name
2 Rated current
3 Ground capacitor code

  • * The attenuation characteristic differs depending on the ground capacitor code.

4 Option D: DIN rail mounting type

  • * The external shape differs when the option is set. Please refer to the drawing.

Ground capacitor code

CodeLeakage current
Input 125/250 V 60 Hz
Capacitor capacity
(Nominal value)
68175.5 µA / 150 µA max680 pF
1020.13 mA / 0.25 mA max 1,000 pF
2220.25 mA / 0.5 mA max2,200 pF
3320.38 mA / 0.75 mA max 3,300 pF
4720.5 mA / 1.0 mA max4,700 pF

Product specifications

ItemNBC-06-472 NBC-10-472NBC-16-472NBC-20-472NBC-30-472
Rated Voltage〔V〕AC 1⌀ 250 / DC250
Rated current〔A〕610162030
Test voltage (Between terminals and mounting plates)2,500 V AC (cutoff current = 20 mA), 1-minute, normal temperature normal humidity 
Insulation resistance (Between terminals and mounting plates)500 V DC 100 MΩ min normal temperature normal humidity
Leakage current 125/250 V 60 Hz0.5 mA / 1.0 mA max
Voltage drop1.0 V max
Safety standard certified temperature— 25 to + 85°C (Refer to the derating characteristics)
Operating Temperature— 40 to + 85°C (Refer to the derating characteristics)
Operating Humidity20 to 95% RH (No condensation)
Storage temperature/humidity— 40 to + 85°C, 20 to 95% RH (No condensation)
Vibration10 to 55 Hz, 19.6 m/s^2 (2 G), period 3 minutes X, Y, Z direction 1 hour each
Impact196.1 m/s^2 (20 G) 11 ms X, Y, Z direction 1 time each
Safety StandardUL1283, CSA C22.2 No.8 (C-UL), DIN EN60939 VDE0565 Teil 3-1, ENEC (Except for DC input)
External dimensions (excluding protrusions) / weight53 × 41 × 92 mm (W × H × D) / 270 g max (Option: for -D, refer to the drawing)

Circuit Configuration

Circuit Configuration

Derating characteristics

Derating characteristics

Drawing

Since this product uses a push-down terminal block, it is shipped in the following conditions.
1 Terminal block cover is stored.
2 Terminal block screw is retained on the upper side.

Standard type

Standard type

DIN rail mounting type

DIN rail mounting type

  • * Tolerance: ±1
  • * Weight: 270 g max
  • * Mounting plate material: Steel (surface treatment: nickel plating) t = 1.0
  • * Case material: PBT
  • * Unit mm
  • * Terminal block tightening torque M4: 1.6 N⋅m (16.9 kgf⋅cm) max

Precautions for mounting DIN rail

Grounding through a DIN rail may not provide the proper noise attenuation effect.
Grounding should be done by connecting to the protective ground terminal (PE) of the noise filter main body.
There are 2 protective ground terminals, but you can use it even by connecting only one of them.

Precautions for mounting DIN rail

Characteristic data (Representative example)

NBC-06-472

Attenuation characteristic (Static characteristics)

Attenuation characteristic (Static characteristics)

NBC-10-472

Attenuation characteristic (Static characteristics)

Attenuation characteristic (Static characteristics)

NBC-16-472

Attenuation characteristic (Static characteristics)

Attenuation characteristic (Static characteristics)

NBC-20-472

Attenuation characteristic (Static characteristics)

Attenuation characteristic (Static characteristics)

NBC-30-472

Attenuation characteristic (Static characteristics)

Attenuation characteristic (Static characteristics)

Selection Support Information

Figure 2 8.3 comparison example of attenuation characteristics between 1-stage filter and 2-stage filter

Figure 2 8.3 comparison example of attenuation characteristics between 1-stage filter and 2-stage filter

The figure on the left shows a comparison example of the attenuation characteristics between 1-stage filter and 2-stage filter.

Part Number
NBC-10-472
NBC-30-472
Part NumberMinimum order quantityVolume DiscountDays to ShipRoHSRated Current
(A)
Mounting Method H
(mm)
1 Piece(s) 16 Day(s) or more 1010Fasten With Screws41
1 Piece(s) 16 Day(s) or more -30Fasten With Screws41

Loading...

  1. 1
 

Basic Information

Input Type Single-Phase Wiring Method Screw Fastening Safety standards UL / CUL / CSA
D(mm) 92 W(mm) 53 Representative standards (VDE) Corresponds To
Representative standards (ENEC) Corresponding (excluding time of DC input) 150 kHz to 1 MHz, high attenuation Corresponds To Leak current value(mA max) 1(250V60Hz)

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:021-8990-4102 / FAX:021-8990-5803
8:30am - 5:30pm (Monday - Friday)