(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Pembayaran dengan kartu kredit untuk sementara tidak tersedia karena kendala sistem. Sementara waktu Anda dapat meggunakan metode Pembayaran di Muka atau QRIS. Untuk informasi lebih lanjut, silakan hubungi Customer Service : TEL: 021-8984-0008 E-mail: cs@misumi.co.id. WA: 08118984008. Kami mohon maaf atas ketidaknyamanan yang terjadi.
    Credit card payments are temporarily unavailable due to system issues. Meanwhile, you can use the Advance Payment method or QRIS. For further information, please contact Customer Service: TEL: 021-8984-0008 E-mail: cs@misumi.co.id. WA: 08118984008. We apologize for any inconvenience caused.
  • Pemberitahuan Jadwal Pemeliharaan : Situs ini akan tidak tersedia dikarenaka jadwal pemeliharaan mulai dari 8:00 21/4/2024 sampai dengan 5:00 pada tanggal 22/4/2024. Kami mohon maaf atas ketidaknyamanan yang terjadi.
    Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 8:00 21/4/2024 to 5:00 (WIB) 22/4/2024. We apologize for the inconvenience.
  • Sehubungan dengan adanya Peraturan Baru Kementerian Perdagangan No.36 Tahun 2023 tentang Pembatasan Impor Barang, MISUMI Indonesia melakukan tindakan pencegahan. Lihat informasi detailnya di sini
    Due to New Regulation of Ministry Of Trade No.36 of 2023 concerning retrictions on imports of goods, MISUMI Indonesia do precautions measure. See detail information here

Locker Switch With Reset Function A8G

Locker Switch With Reset Function A8G

Rocker switch with reset function for high-capacity switching.
[Features]
・ Effective for energy saving with reset function by external signal
・ Achieves excellent inrush current performance and 20 A opening and closing with a unique opening and closing mechanism
・ Contact configuration is 2-pole double heads
・ Contact gap 3 mm or more
・ UL, cUL accredited. EN standard compliant
[Applications]
・ As an operation / power supply / changeover switch for various devices

PDF

Japanese Only

Part Number

Configured Part Number is shown.

A8G-107-1-24

A8G Series With Reset Function

Rocker Switch With Reset Function A8G: related images

A8G series appearance

Rocker Switch With Reset Function A8G: related images

Unit: mm
Operating properties
Force required for operation OF Max: 19.6 N

Contact

ItemNon-inductive Load (A)Inductive Load (A)
Rated Voltage (V)Resistive LoadLamp LoadInductive LoadElectric Motor Load
250 V AC201088

Note 1. Lamp load has a 10x inrush current.
Note 2. Inductive loads will have a power factor of 0.4 or higher (AC).
Note 3. Electric motors have a 6x inrush current.
Note 4. The rated values described above were tested in the conditions below.

  • 1. Ambient temperature: 20 ±2℃
  • 2. Ambient humidity: 65 ±5% RH
  • 3. Operating frequency: 7 times/min.

Reset Coil

Rated Voltage (V)
(Usable Voltage Range)
Open Contact Voltage
(Coil Temperature 20 ±2°C)
Rated Value Excitation Current
(Coil Temperature 20 ±2°C)
Coil Resistance
(Coil Temperature 20 ±2°C)
Permitted Application Time
24 V DC ±10%
(21.6 to 26.4 V DC)
21.6 V or less185 mA ±20%130Ω ±20%100 ms or more
1s or less

Note 1. Please do not flow current to the coil for over 10 seconds. This may cause loss of performance.
Note 2. If the reset coil is controlled using a semiconductor element, etc., make sure that any residual voltage generated due to leakage current is 2.4 V DC or less.

Performance

Permitted Operation FrequencyMechanicalSwitch operation: 7 times/min. or less; Coil operation: 7 times/min. or less
Electrical20 times/min. or less
Insulation Resistance100 MΩ or higher (insulation resistance meter at 500 V DC)
Contact Resistance (Initial Value)100 mΩ or lower (6 to 8 V DC, 1 A voltage drop method)
Withstand VoltageBetween Same Pole Terminals2,000 V AC 50/60 Hz 1 min
Between Different Pole Terminals2,000 V AC 50/60 Hz 1 min
Metal And Ground Components For Charging4,000 V AC 50/60 Hz 1 Min.
VibrationMalfunction10 to 55 Hz double amplitude 1.5 mm (malfunction within 1 ms)
ShockMalfunction98 m/s2 or higher (malfunction within 1 ms)
DurabilityMax. 500 m/s2
DurabilityElectricalSwitch operation: 50,000 times or more; Coil operation: 10,000 times or more
MechanicalSwitch operation: 100,000 times or more
Inrush CurrentMax. 100 A
Protective StructureIEC IP40
Open Contact Time *100 ms or less
Operating Temperature Range-10 to +55℃ (with no icing and no condensation)
Operating Humidity Range45 to 85%

*Time between applying voltage to the coil and when the contact (between 1-2, 4-5) opens.

  • *Please see the catalog for other specifications and important points.
Part Number
A8G-107-1-24
Part NumberMinimum order quantityVolume DiscountDays to ShipRoHS
1 Piece(s) Same day 10

Loading...

  1. 1
 

Basic Information

Shape Rectangle Illumination Non-Illumination Contact Configuration 2-pole double throw
With key NA Terminal shape Tab Terminal Protection function (environmentally resistant) Available
Dimension vertical(mm) 37 Dimension width(mm) 27 Dimension depth(mm) 33
Contact rated 1 (resistant load)(V)/(A) AC250/20 Works with micro loads NA Reset function (external control) Available
Operation Unit Integrated style Operating unit marking NA Button color Black
Case color Black Protective Structure IP40

Please check the type/dimensions/specifications of the part A8G-107-1-24 in the Locker Switch With Reset Function A8G series.

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:021-8990-4102 / FAX:021-8990-5803
8:30am - 5:30pm (Monday - Friday)