(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Pembayaran dengan kartu kredit untuk sementara tidak tersedia karena kendala sistem. Sementara waktu Anda dapat meggunakan metode Pembayaran di Muka atau QRIS. Untuk informasi lebih lanjut, silakan hubungi Customer Service : TEL: 021-8984-0008 E-mail: cs@misumi.co.id. WA: 08118984008. Kami mohon maaf atas ketidaknyamanan yang terjadi.
    Credit card payments are temporarily unavailable due to system issues. Meanwhile, you can use the Advance Payment method or QRIS. For further information, please contact Customer Service: TEL: 021-8984-0008 E-mail: cs@misumi.co.id. WA: 08118984008. We apologize for any inconvenience caused.
  • Pemberitahuan Jadwal Pemeliharaan : Situs ini akan tidak tersedia dikarenaka jadwal pemeliharaan mulai dari 8:00 21/4/2024 sampai dengan 5:00 pada tanggal 22/4/2024. Kami mohon maaf atas ketidaknyamanan yang terjadi.
    Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 8:00 21/4/2024 to 5:00 (WIB) 22/4/2024. We apologize for the inconvenience.
  • Sehubungan dengan adanya Peraturan Baru Kementerian Perdagangan No.36 Tahun 2023 tentang Pembatasan Impor Barang, MISUMI Indonesia melakukan tindakan pencegahan. Lihat informasi detailnya di sini
    Due to New Regulation of Ministry Of Trade No.36 of 2023 concerning retrictions on imports of goods, MISUMI Indonesia do precautions measure. See detail information here

CT Built-in Solid State Relay G3PF

CT Built-in Solid State Relay G3PF
  • Volume Discount

[Features]
· Built-in CT, new concept SSR allows for heater disconnection detection and SSR short-circuit malfunction detection.
· Built-in CT, promotes reduction in wiring man-hours.
· Can detect single disconnection in multiple heaters.
· Can detect disconnection in 3-phase heaters.
· Can detect SSR short-circuit malfunctions.
· Abnormality detection level can be easily set by switch.
· Both DIN rail mounting and screw mounting are possible.
· 3 types of input terminals are available: M3 terminal, screwless clamp terminal (removable), and small minus terminal (removable).
· CSA standards, EN standards (TÜV certification) acquired.
· UL standard acquired (model G3PF-2□□B-□□□ series).

PDF

Japanese Only

G3PF-225B Specifications

Solid State Relay G3PF With Built-In Current Transformer: related images

G3PF-225B external appearance

Solid State Relay G3PF With Built-In Current Transformer: related images

G3PF-225B dimensional outline drawing, Units: mm

Solid State Relay G3PF With Built-In Current Transformer: related images

G3PF-225B dimensional outline drawing, Units: mm

Solid State Relay G3PF With Built-In Current Transformer: related images

Mounting hole dimensions, Units: mm

G3PF-235B specifications

Solid State Relay G3PF With Built-In Current Transformer: related images

G3PF-235B external appearance

Solid State Relay G3PF With Built-In Current Transformer: related images

G3PF-235B dimensional outline drawing, Units: mm

Solid State Relay G3PF With Built-In Current Transformer: related images

G3PF-235B dimensional outline drawing, Units: mm

Solid State Relay G3PF With Built-In Current Transformer: related images

G3PF-235B mounting hole dimensions, Units: mm

"m-h3--wysiwyg">Ratings

Detection Power Supply

Rated Power Supply Voltage24 V DC
Operating Voltage Range20.4 to 26.4 V DC
Current ConsumptionDC 50 mA max. (at 24 V DC)

Operation Input

Input MethodVoltage Input
Rated Input Voltage12 to 24 V DC
Operating Input Voltage Range9.6 to 26.4 V DC
Operating Voltage9.6 V DC max.
Release Voltage1.0 V DC min.
Input CurrentDC 5 mA max. (with 12 V DC)
DC 10 mA max. (with 24 V DC)

Alarm Output

Output OFF Collector Voltage30 V DC max.
Maximum Carry Current100 mA
Output FormatNPN open collector
(ON when error is detected)
Minimum Load Current0.1 mA
  • *If the power rise or fall time exceeds 200 ms for the detection power supply or operating input power supply, an alarm display or output may be activated by the failure detection function before the rated voltage is exceeded. Select a DC power supply that has a power rise or fall time of 200 ms or less.

Main Circuit

Model _x000D_Model G3PF-225BModel G3PF-235B
Model G3PF-225B-CTBModel G3PF-235B-CTB
Rated Load Voltage100 to 240 V AC 50/60 Hz
Operating Voltage Range75 to 264 V AC 50/60 Hz
Rated Carry Current *25 A (with 40°C)35 A (with 40°C)
Minimum Load Current2 A
Inrush Current220 A
(60 Hz, 1 cycle)
430 A
(60 Hz, 1 cycle)

* Differs depending on ambient temperature. For details, see the catalog characteristics data "● Rated Load Current—Ambient Temperature."

Performance

FormatModel G3PF-225BModel G3PF-235B
Model G3PF-225B-CTBModel G3PF-235B-CTB
Operating Time1/2 of load power source cycle + 1 ms max.
Release Time1/2 of load power source cycle + 1 ms max.
Main CircuitOutput On Voltage Drop1.6 V (RMS) max.
Leakage Current10 mA max. (at 200 V AC)
Alarm OutputOutput On Voltage Drop1.5 V max.
Leakage Current1 μA max.
Insulation Resistance100 MΩ min. (with 500 V ohmmeter)
Dielectric Strength2,500 V AC 50/60 Hz for 1 min
Vibration10 to 55 to 10 Hz, 0.35-mm single amplitude (0.7-mm double amplitude)
Shock294 m/s2
Storage Temperature-30 to +70°C (assuming no icing or condensation)
Ambient Operating Temperature-20 to +60°C (assuming no icing or condensation)
Ambient Operating Humidity45 to 85% RH
WeightApprox. 400 gApprox. 630 g

Common Items

  • Mount to DIN Track or with screws.
  • Three types of input terminals available: M3 terminals, screwless clamp terminals (detachable), or compact slotted screw terminals (detachable).
  • Certified for CSA and EN (TÜV).
  • The G3PF-2□□B-□□□ Series is UL certified.
  • *See the catalog for product information other than that listed above.
Part Number
G3PF-225B-CTB DC24
G3PF-225B DC24
G3PF-235B-CTB DC24
G3PF-235B DC24
Part NumberMinimum order quantityVolume DiscountDays to ShipRoHSTerminal shape Dimension height
(mm)
Dimension width
(mm)
Dimension depth
(mm)
Applicable output load
(A)/(V)
Function
1 Piece(s) 16 Day(s) or more 10Screwless clamp terminal100451102 to 25A/AC100 to 240VWarning Output 2 Point
1 Piece(s) 16 Day(s) or more -Screw Fastening77.6451102 to 25A/AC100 to 240VWarning Output 1 Point
1 Piece(s)Available 16 Day(s) or more -Screwless clamp terminal77.6551372 to 35A/AC100 to 240VWarning Output 2 Point
1 Piece(s) 16 Day(s) or more 10Screw Fastening100551302 to 35A/AC100 to 240VWarning Output 1 Point

Loading...

  1. 1
 

Basic Information

Application SSR Safety standards CE / UL / TUV / CSA Insulation method Phototriac Coupler
Zero cross function Available Operation Indicator Lamp Available Input rated voltage(V) DC 12–24

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:021-8990-4102 / FAX:021-8990-5803
8:30am - 5:30pm (Monday - Friday)