Solid State/Relay G3S/G3SD

Solid State/Relay G3S/G3SD
  • Volume Discount

[Features]
· An ultra small type that is capable of switching up to 1 A.
· A smaller version of the dual inline package (DIP).
· The G6B features an identical arrangement of electromagnetic relays and terminals and can be mixed and matched as needed depending on the application.
· Allows for cluster mounting, including the mounting of radiators in sets.
· Types for AC loads and DC loads available.
· Features high AC2,500V isolation between the input and output.
· The built-in varistor provides effective absorption of external surges (for AC switching).

PDF

Japanese Only

 

Solid State Relay G3S/G3SD: related images

Solid State Relay G3S/G3SD external appearance

Solid State Relay G3S/G3SD: related images

 

Solid State Relay G3S/G3SD dimensional outline drawing

  • Units: mm

 

Solid State Relay G3S/G3SD: related images

 

PCB processing dimensions

  • Units: mm
  • The dimensional tolerance is ±0.1 mm.

 

Solid State Relay G3S/G3SD: related images

 

Terminal layout/connection

  • Values within ( ) are for Model G3SD

 

Insulation MethodZero Cross FunctionOperation Indicator LampApplicable Output LoadRated Input VoltageModel
PhototriacNN1 A 100 to 240 V AC *15 V DCModel G3S-201PL
24 V DC
1.2 A 100 to 240 V AC *124 V DCModel G3S-201PL-PD
Photo Coupler1 A 4 to 24 V DC *25 V DCModel G3SD-Z01P
24 V DC
1.1 A 4 to 24 V DC *224 V DCModel G3SD-Z01P-PD
  • *The G3S-201PL-PD-US DC24 is an international standard certified product. Contact the manufacturer for details.

*1. 250 V AC is displayed for the actual product.
*1. 24 V DC is displayed for the actual product.

Ratings

Input

5 V DC and 24 V DC input voltage specifications are available for each model type.

Rated VoltageVoltage UsedOperating Voltage LevelRelease Voltage LevelInput Impedance
Model G3S-201PL
Model G3S-201PL-PD
Model G3SD-Z01P
Model G3SD-Z01P-PD
DC5 V4 to 6 V DC4 V DC or Less1 V DC or More450Ω ±20%-
24 V19.2 to 28.8 V DC19.2 V DC or Less2.2 kΩ ±20%2.8 kΩ ±20%

Output

ModelRated Load VoltageLoad Voltage RangeLoad CurrentInrush Current
Model G3S-201PL100 to 240 V AC75 to 264 V AC0.1 to 1 A *15 A
(60 Hz, 1 Cycle)
Model G3S-201PL-PD0.1 to 1.2 A *
Model G3SD-Z01P4 to 24 V DC3 to 26 V DC0.01 to 1 A *3 A (10 ms)
Model G3SD-Z01P-PD0.01 to 1.1 A *

*The applicable output load current may vary depending on the ambient temperature.
For details, refer to the reference data in the "Load Current - Ambient Temperature Ratings" section of the catalog.

Performance

ModelModel G3S-201PL
Model G3S-201PL-PD
Model G3SD-Z01P
Model G3SD-Z01P-PD
Turn-ON Time1 ms or Less1 ms or Less
Turn-OFF Time1/2 cycle of load power source + 1 ms or less1 ms or Less
Output On Voltage Drops1.6 V (RMS) or Less1.5 V or Less
Leakage Current2 mA or Less (at 200 V AC)0.1 mA or Less (at 26 V DC)
Insulation Resistance100 MΩ or More (with 500 V DC Megohmmeter)
Withstand VoltageInput-Output 2,500 V AC 50/60 Hz 1 min
Vibration10 to 55 to 10 Hz, Semi Amplitude 0.75 mm (Double Amplitude 1.5 mm)
Shock / Impact1,000 m/s2
Storage Temperature-30 to +100°C (Assuming No Freezing or Condensation)
Ambient Operating Temperature-30 to +80°C (Assuming No Freezing or Condensation)
Operating Ambient Humidity45 to 85% RH
WeightApprox. 13 g

Precautions

  • Model G3S-201PL-PD and Model G3SD-Z01-PD can be mounted together.
  • If mounting together, be sure to also mount the Model Y92B-S08N heat sink.
  • Before mounting the heat sink, be sure to apply thermal silicone grease (Momentive Performance Materials YG6260, Shin-Etsu Chemical G747 etc.) to the mounting surface.
  • As detailed below, the load current - ambient temperature rating will be lower when mounted together (with the heat sink).
Solid State Relay G3S/G3SD: related images

When mounted together

Solid State Relay G3S/G3SD: related images

 

Load current - ambient temperature ratings (equal load currents for 4 units when mounted together)

  • Load current (A)
  • Ambient temperature (°C)

 

Part Number
G3S-201PL DC5
G3SD-Z01P-PD DC24
Part NumberMinimum order quantityVolume DiscountDays to ShipRoHSInsulation method Rated load voltage
(V)
Max Load Current
(A)
Input rated voltage
(V)
1 Piece(s)Available Same day 10PhototriacAC 100–2400.1–1DC5
1 Piece(s) Same day 10Photo couplerDC4 to 240.01–1.1DC24

Loading...

  1. 1
 

Basic Information

Application SSR Latch function NA Terminal shape For PCB
Dimension height(mm) 16.5 Dimension width(mm) 20 Dimension depth(mm) 10
Circuit Board Mounting Circuit Board Hole Insertion

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:021-8990-4102 / FAX:021-8990-5803
8:30am - 5:30pm (Monday - Friday)