(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Pembayaran dengan kartu kredit untuk sementara tidak tersedia karena kendala sistem. Sementara waktu Anda dapat meggunakan metode Pembayaran di Muka atau QRIS. Untuk informasi lebih lanjut, silakan hubungi Customer Service : TEL: 021-8984-0008 E-mail: cs@misumi.co.id. WA: 08118984008. Kami mohon maaf atas ketidaknyamanan yang terjadi.
    Credit card payments are temporarily unavailable due to system issues. Meanwhile, you can use the Advance Payment method or QRIS. For further information, please contact Customer Service: TEL: 021-8984-0008 E-mail: cs@misumi.co.id. WA: 08118984008. We apologize for any inconvenience caused.
  • Sehubungan dengan adanya Peraturan Baru Kementerian Perdagangan No.36 Tahun 2023 tentang Pembatasan Impor Barang, MISUMI Indonesia melakukan tindakan pencegahan. Lihat informasi detailnya di sini
    Due to New Regulation of Ministry Of Trade No.36 of 2023 concerning retrictions on imports of goods, MISUMI Indonesia do precautions measure. See detail information here
  • Nomor telepon alternatif Kontak Layanan Pelanggan : 021-29182911| 021-29182991 | 021-29182997 | 021-29182998
    Alternative telephone number Contact Customer Service: 021-29182911 | 021-29182991 | 021-29182997 | 021-29182998

Unitz E3000 series

Unitz E3000 series

· Single-phase, phase-control system, thyristor type feedback control model
· For stable control of halogen lamp heaters, pure metal heaters, SiC, carbon heaters, etc.
· Can be used under poor power supply conditions such as power supply voltage variations, instantaneous power failures, power supply surges, square waves, rectangular waves, etc.
· Suppresses erroneous control troubles in case of transformer loads
· Power supply voltage variation allowable range 30-440V
· Used in areas where voltage variation is severe, such as Southeast Asia
· Has been employed in semiconductor devices that require safety, reliability, and stability.
· Optimal for near infrared heaters that require output stability performance.

Part Number

Configured Part Number is shown.

Part Number
E3031-1
E3031-1-G
E3031-1-R
E3031-1-RG
E3031-2
E3031-2-G
E3031-2-R
E3031-2-RG
E3031-3
E3031-3-G
E3031-3-R
E3031-3-RG
E3032-1
E3032-1-G
E3032-1-R
E3032-1-RG
E3032-2
E3032-2-G
E3032-2-R
E3032-2-RG
E3032-3
E3032-3-G
E3032-3-R
E3032-3-RG
E3034-1
E3034-1-G
E3034-1-R
E3034-1-RG
E3034-2
E3034-2-G
E3034-2-R
E3034-2-RG
E3034-3
E3034-3-G
E3034-3-R
E3034-3-RG
E3061-1
E3061-1-G
E3061-1-R
E3061-1-RG
E3061-2
E3061-2-G
E3061-2-R
E3061-2-RG
E3061-3
E3061-3-G
E3061-3-R
E3061-3-RG
E3062-1
E3062-1-G
E3062-1-R
E3062-1-RG
E3062-2
E3062-2-G
E3062-2-R
E3062-2-RG
E3062-3
E3062-3-G
E3062-3-R
E3062-3-RG
Part NumberMinimum order quantityVolume DiscountDays to ShipInput Voltage
(V)
Rated Current
(A)
Dimension length
(mm)
Dimension width
(mm)
Dimension thickness
(mm)
Control input type Option
1 Piece(s) 14 Day(s) or more AC100-1203020021080DC 4–20 mA (receiver resistance: 100 Ω)-
1 Piece(s) 14 Day(s) or more AC100-1203020021080DC 4–20 mA (receiver resistance: 100 Ω)Gradient volume
1 Piece(s) 14 Day(s) or more AC100-1203020021080DC 4–20 mA (receiver resistance: 100 Ω)Remote gain input (external gradient setting)/control input are identical type
1 Piece(s) 14 Day(s) or more AC100-1203020021080DC 4–20 mA (receiver resistance: 100 Ω)R/G simultaneous selection
1 Piece(s) 14 Day(s) or more AC100-1203020021080DC0-5V-
1 Piece(s) 14 Day(s) or more AC100-1203020021080DC0-5VGradient volume
1 Piece(s) 14 Day(s) or more AC100-1203020021080DC0-5VRemote gain input (external gradient setting)/control input are identical type
1 Piece(s) 14 Day(s) or more AC100-1203020021080DC0-5VR/G simultaneous selection
1 Piece(s) 14 Day(s) or more AC100-1203020021080DC0-10V-
1 Piece(s) 14 Day(s) or more AC100-1203020021080DC0-10VGradient volume
1 Piece(s) 14 Day(s) or more AC100-1203020021080DC0-10VRemote gain input (external gradient setting)/control input are identical type
1 Piece(s) 14 Day(s) or more AC100-1203020021080DC0-10VR/G simultaneous selection
1 Piece(s) 12 Day(s) or more AC200-2403020021080DC 4–20 mA (receiver resistance: 100 Ω)-
1 Piece(s) 14 Day(s) or more AC200-2403020021080DC 4–20 mA (receiver resistance: 100 Ω)Gradient volume
1 Piece(s) 14 Day(s) or more AC200-2403020021080DC 4–20 mA (receiver resistance: 100 Ω)Remote gain input (external gradient setting)/control input are identical type
1 Piece(s) 14 Day(s) or more AC200-2403020021080DC 4–20 mA (receiver resistance: 100 Ω)R/G simultaneous selection
1 Piece(s) 12 Day(s) or more AC200-2403020021080DC0-5V-
1 Piece(s) 14 Day(s) or more AC200-2403020021080DC0-5VGradient volume
1 Piece(s) 14 Day(s) or more AC200-2403020021080DC0-5VRemote gain input (external gradient setting)/control input are identical type
1 Piece(s) 14 Day(s) or more AC200-2403020021080DC0-5VR/G simultaneous selection
1 Piece(s) 12 Day(s) or more AC200-2403020021080DC0-10V-
1 Piece(s) 14 Day(s) or more AC200-2403020021080DC0-10VGradient volume
1 Piece(s) 14 Day(s) or more AC200-2403020021080DC0-10VRemote gain input (external gradient setting)/control input are identical type
1 Piece(s) 14 Day(s) or more AC200-2403020021080DC0-10VR/G simultaneous selection
1 Piece(s) 12 Day(s) or more AC380-4403020021080DC 4–20 mA (receiver resistance: 100 Ω)-
1 Piece(s) 14 Day(s) or more AC380-4403020021080DC 4–20 mA (receiver resistance: 100 Ω)Gradient volume
1 Piece(s) 14 Day(s) or more AC380-4403020021080DC 4–20 mA (receiver resistance: 100 Ω)Remote gain input (external gradient setting)/control input are identical type
1 Piece(s) 14 Day(s) or more AC380-4403020021080DC 4–20 mA (receiver resistance: 100 Ω)R/G simultaneous selection
1 Piece(s) 12 Day(s) or more AC380-4403020021080DC0-5V-
1 Piece(s) 14 Day(s) or more AC380-4403020021080DC0-5VGradient volume
1 Piece(s) 14 Day(s) or more AC380-4403020021080DC0-5VRemote gain input (external gradient setting)/control input are identical type
1 Piece(s) 14 Day(s) or more AC380-4403020021080DC0-5VR/G simultaneous selection
1 Piece(s) 12 Day(s) or more AC380-4403020021080DC0-10V-
1 Piece(s) 14 Day(s) or more AC380-4403020021080DC0-10VGradient volume
1 Piece(s) 14 Day(s) or more AC380-4403020021080DC0-10VRemote gain input (external gradient setting)/control input are identical type
1 Piece(s) 14 Day(s) or more AC380-4403020021080DC0-10VR/G simultaneous selection
1 Piece(s) 14 Day(s) or more AC100-1206021025090DC 4–20 mA (receiver resistance: 100 Ω)-
1 Piece(s) 14 Day(s) or more AC100-1206021025090DC 4–20 mA (receiver resistance: 100 Ω)Gradient volume
1 Piece(s) 14 Day(s) or more AC100-1206021025090DC 4–20 mA (receiver resistance: 100 Ω)Remote gain input (external gradient setting)/control input are identical type
1 Piece(s) 14 Day(s) or more AC100-1206021025090DC 4–20 mA (receiver resistance: 100 Ω)R/G simultaneous selection
1 Piece(s) 14 Day(s) or more AC100-1206021025090DC0-5V-
1 Piece(s) 14 Day(s) or more AC100-1206021025090DC0-5VGradient volume
1 Piece(s) 14 Day(s) or more AC100-1206021025090DC0-5VRemote gain input (external gradient setting)/control input are identical type
1 Piece(s) 14 Day(s) or more AC100-1206021025090DC0-5VR/G simultaneous selection
1 Piece(s) 14 Day(s) or more AC100-1206021025090DC0-10V-
1 Piece(s) 14 Day(s) or more AC100-1206021025090DC0-10VGradient volume
1 Piece(s) 14 Day(s) or more AC100-1206021025090DC0-10VRemote gain input (external gradient setting)/control input are identical type
1 Piece(s) 14 Day(s) or more AC100-1206021025090DC0-10VR/G simultaneous selection
1 Piece(s) 12 Day(s) or more AC200-2406021025090DC 4–20 mA (receiver resistance: 100 Ω)-
1 Piece(s) 14 Day(s) or more AC200-2406021025090DC 4–20 mA (receiver resistance: 100 Ω)Gradient volume
1 Piece(s) 14 Day(s) or more AC200-2406021025090DC 4–20 mA (receiver resistance: 100 Ω)Remote gain input (external gradient setting)/control input are identical type
1 Piece(s) 14 Day(s) or more AC200-2406021025090DC 4–20 mA (receiver resistance: 100 Ω)R/G simultaneous selection
1 Piece(s) 12 Day(s) or more AC200-2406021025090DC0-5V-
1 Piece(s) 14 Day(s) or more AC200-2406021025090DC0-5VGradient volume
1 Piece(s) 14 Day(s) or more AC200-2406021025090DC0-5VRemote gain input (external gradient setting)/control input are identical type
1 Piece(s) 14 Day(s) or more AC200-2406021025090DC0-5VR/G simultaneous selection
1 Piece(s) 12 Day(s) or more AC200-2406021025090DC0-10V-
1 Piece(s) 14 Day(s) or more AC200-2406021025090DC0-10VGradient volume
1 Piece(s) 14 Day(s) or more AC200-2406021025090DC0-10VRemote gain input (external gradient setting)/control input are identical type
1 Piece(s) 14 Day(s) or more AC200-2406021025090DC0-10VR/G simultaneous selection