(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Pembayaran dengan kartu kredit untuk sementara tidak tersedia karena kendala sistem. Sementara waktu Anda dapat meggunakan metode Pembayaran di Muka atau QRIS. Untuk informasi lebih lanjut, silakan hubungi Customer Service : TEL: 021-8984-0008 E-mail: cs@misumi.co.id. WA: 08118984008. Kami mohon maaf atas ketidaknyamanan yang terjadi.
    Credit card payments are temporarily unavailable due to system issues. Meanwhile, you can use the Advance Payment method or QRIS. For further information, please contact Customer Service: TEL: 021-8984-0008 E-mail: cs@misumi.co.id. WA: 08118984008. We apologize for any inconvenience caused.
  • Pemberitahuan Jadwal Pemeliharaan : Situs ini akan tidak tersedia dikarenaka jadwal pemeliharaan mulai dari 8:00 21/4/2024 sampai dengan 5:00 pada tanggal 22/4/2024. Kami mohon maaf atas ketidaknyamanan yang terjadi.
    Scheduled Maintenance Notice: This site will be unavailable due to scheduled maintenance from 8:00 21/4/2024 to 5:00 (WIB) 22/4/2024. We apologize for the inconvenience.
  • Sehubungan dengan adanya Peraturan Baru Kementerian Perdagangan No.36 Tahun 2023 tentang Pembatasan Impor Barang, MISUMI Indonesia melakukan tindakan pencegahan. Lihat informasi detailnya di sini
    Due to New Regulation of Ministry Of Trade No.36 of 2023 concerning retrictions on imports of goods, MISUMI Indonesia do precautions measure. See detail information here

Non-Magnetic/Non-Energization New Pic-Test (U Series)

Non-Magnetic/Non-Energization New Pic-Test (U Series)

[Features]
· Gauge heads and pointers are non-magnetic, so they are not affected by magnetic environments.
· The use of ceramic stems achieves non-conductivity, allowing use in electric discharge machines, etc.
· Easy to read light blue scale.
· Select from 0.01 mm, 0.002 mm, or 0.001 mm types.
· The gauge damage prevention probe is provided on all models.
· By adopting a balancing needle, errors due to difference in posture (gauge mounting direction) are minimized.
· Improved abrasion resistance with a probe with a ruby ball.

PDF

Part Number

Configured Part Number is shown.

 
Part Number
PCN-1AU
PCN-1BU
PCN-1LU
PCN-2BU
PCN-2U
PCN-5U
PCN-6U
PCN-SU
Part NumberMinimum order quantityVolume DiscountDays to ShipScale Interval / Minimum Display
(mm)
Measuring Range
(mm)
Detailed Type Scale Specification [Accuracy (µm)] Wide range bound accuracy [Accuracy (µm)] Adjacent Error
(µm)
[Accuracy (µm)] Return Error
(µm)
Specifications
1 Piece(s) 18 Day(s) or more 0.010.5Vertical No Clutch Type0-25-0553· No-clutch type · Equipped with measurement probe XN1A-2R
1 Piece(s) 14 Day(s) or more 0.010.8Vertical No Clutch Type0-40-0853· No-clutch type · Equipped with measurement probe XN1B-2R
1 Piece(s) 16 Day(s) or more 0.011Vertical No Clutch Type0-50-01054· No-clutch type · Equipped with measurement probe XN1L-2R
1 Piece(s) 14 Day(s) or more 0.0020.2Vertical No Clutch Type0-100-0322· No-clutch type · Equipped with measurement probe XN2B-2R
1 Piece(s) 18 Day(s) or more 0.0020.28Vertical No Clutch Type0-140-0322· No-clutch type · Equipped with measurement probe XN2-2R
1 Piece(s) 16 Day(s) or more 0.010.5Vertical, non-clutch type0-25-0553· No-clutch type · Equipped with measurement probe XN1A-2R
1 Piece(s) 18 Day(s) or more 0.0020.28Vertical, non-clutch type0-140-0322· No-clutch type · Equipped with measurement probe XN2-2R
1 Piece(s) 15 Day(s) or more 0.0010.14Vertical No Clutch Type0-70-0322· No-clutch type · High precision · Equipped with measurement probe XNS-2R

Loading...

  1. 1

Basic Information

Use Lever Type (Indicator) Display Method Dial Maximum Measuring Length (Adjustment Range)(mm) 0 ~ 1
Scale type Balance scale Measuring Force (or Less)(N) 0.3 Features Because the probe and pointer are nonmagnetic, they are not easily affected by magnetic environments. The use of ceramic stems achieves non-conductivity, which allows them to be used in electric discharge machines, etc. The pale blue scale indicators are easy to read. Indicators can be selected from 0.01 mm/0.002 mm/0.001 mm types. Gauge breakage prevention probes are attached to all instrument types. Adoption of balancing needles keeps errors due to posture differences (gauge mounting direction) as small as possible. Resistance to wear is improved via the adoption of measuring probes with ruby spheres. (φ2 standard types only)

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:021-8990-4102 / FAX:021-8990-5803
8:30am - 5:30pm (Monday - Friday)