Measuring Environment Logger

Measuring Environment Logger

Records measurement data from the meter as a set with environmental data, equipped with temperature/humidity/atmospheric pressure/vibration sensors, and can simultaneously measure & record 4 types of data.


[Features]
· Synchronizes and stores measurement data and surrounding environment data.
· Total data storage capacity: 10,000 sets.
· Recording interval: 1 second to 60 minutes.
· Measuring function: 4-channel recording as an individual unit: weighing data input also possible.
· Environmental changes can be displayed in a graph.
· Real-time data transfer with a balance + environment logger + PC.
· No driver software required when connecting with a PC.
· Energy-Saving Function (battery operation)

PDF

Japanese Only

Part Number

Configured Part Number is shown.

AD-1687

 
Part Number
AD-1687
Part NumberMinimum order quantityVolume DiscountDays to ShipRoHS
1 Piece(s) 16 Day(s) or more 10

Loading...

  1. 1

Basic Information

Width(mm) 127 Depth(mm) 36 Height(mm) 90
Recorded Data Count Max. 10,000 sets Supported OS Windows 2000/XP/Vista/7 (32/64 bit Version) Temperature (Minimum Display)(°C) 0.1
Temperature (Measuring Range)(°C) 0-60/85% RH or less (No condensation) Temperature (Measurement Accuracy)(°C) ±0.5 Relative humidity (minimum display)(RH) 0.1%
Relative humidity (measurement range)(RH) 0-100% Relative humidity (measuring accuracy) ±5% Atmospheric Pressure (Minimum Display)(hPa) 0.1
Atmospheric Pressure (Measuring Range)(hPa) 500-1100 Atmospheric Pressure (Measurement Accuracy)(hPa) ±3 Vibration (minimum display)(mG) 1
Vibration (measurable range)(mG) 0-2000 Vibration (measurement precision) Silent Acceleration Ratio ±20% Interface Flowmeter Connection RS-232C, PC Connection USB
Power Supply Power supplied from the balance using RS-232C (can also be supplied from two AA alkaline batteries or USB) Battery life Approx. 6 months (when measured every minute only with alkaline batteries) Mass(g) Approx. 275 (batteries and protectors included)
Accessory RS-232C signal cable for scale and balance connection (3 types, 1 m each), PC connection mini-B type USB cable (1m), 2 AA dry cell batteries for monitor, AC adapter (for USB power source), Operation Instructions Features ● Connect to the RS-232C output of the metering instrument to record both measured data and environment data as a set ● Memory data capacity: max. 10,000 sets ● Dedicated software isn't required for the measurement data since it can be saved as CSV by transferring to a PC using USB Supplement Connection with other companies' devices has not been verified, so proper operation cannot be guaranteed.