(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Pembayaran dengan kartu kredit untuk sementara tidak tersedia karena kendala sistem. Sementara waktu Anda dapat meggunakan metode Pembayaran di Muka atau QRIS. Untuk informasi lebih lanjut, silakan hubungi Customer Service : TEL: 021-8984-0008 E-mail: cs@misumi.co.id. WA: 08118984008. Kami mohon maaf atas ketidaknyamanan yang terjadi.
    Credit card payments are temporarily unavailable due to system issues. Meanwhile, you can use the Advance Payment method or QRIS. For further information, please contact Customer Service: TEL: 021-8984-0008 E-mail: cs@misumi.co.id. WA: 08118984008. We apologize for any inconvenience caused.
  • Sehubungan dengan adanya Peraturan Baru Kementerian Perdagangan No.36 Tahun 2023 tentang Pembatasan Impor Barang, MISUMI Indonesia melakukan tindakan pencegahan. Lihat informasi detailnya di sini
    Due to New Regulation of Ministry Of Trade No.36 of 2023 concerning retrictions on imports of goods, MISUMI Indonesia do precautions measure. See detail information here
  • Nomor telepon alternatif Kontak Layanan Pelanggan : 021-29182911| 021-29182991 | 021-29182997 | 021-29182998
    Alternative telephone number Contact Customer Service: 021-29182911 | 021-29182991 | 021-29182997 | 021-29182998

Insulation Wires for Electric / Electronic / Communication Equipment(Representative Standard:UL)

Insulated wires for electrical, electronic and communications devices supply power to general households and factories, electrical and electronic components in large machinery and communications devices. The wires are made of drawn copper, copper alloys, aluminum, etc., and are used to connect and conduct electricity between 2 points. These wires feature conductors made of copper, etc., covered with an insulator. The wires are classified into insulated wires that transmit high current and those that transmit low current, with insulation material made of vinyl, PVC, polyethylene, etc. Some insulated wires feature fluoropolymer and polyester materials. Some insulated wires also feature a protective coating on top of the insulator.
Days to Ship
  • All
  • Same day
  • 8 Day(s) or Less
  • 10 Day(s) or Less
  • 11 Day(s) or Less
  • 12 Day(s) or Less
  • 15 Day(s) or Less
  1. 1
Brand
Product Series
Days to Ship
Specifications
Conductor Cross Section(mm2)
AWG size(AWG)
Sheath (outer coating) color
Rated Voltage
Properties
Overall Length(m)
Finished outer diameter(mm)
Representative Standard
Insulation body materials
Shield
Logarithm
Sheath (outer coating) material

    UL1061 UL Standard Lead Free Semi-Rigid PVC Cable

      UL3266 UL Standard Lead Free Irradiated Cross-Linked Flame Retardant PE Cable

        Cable NAUL1007 UL Supported

          Cable for Internal Wiring of DY-SOFT Equipment

            UL1430 UL Standard Lead Free Irradiated Cross-Linked PVC Cable

              UL1672 UL Standard Lead Free Irradiated Cross-Linked Vinyl Double Insulated Wire

                UL3265 UL Standard Lead Free Irradiated Cross-Linked Flame Retardant PE Cable

                  CE-362 Power Supply Cable

                    CE-362SB Power Supply Cable

                    Brand

                    HITACHI CABLE

                    HITACHI CABLE

                    MISUMI

                    DYDEN

                    HITACHI CABLE

                    HITACHI CABLE

                    HITACHI CABLE

                    KURAMO ELECTRIC

                    KURAMO ELECTRIC

                    Product Series

                    UL1061 UL Standard Lead Free Semi-Rigid PVC Cable

                    UL3266 UL Standard Lead Free Irradiated Cross-Linked Flame Retardant PE Cable

                    Cable NAUL1007 UL Supported

                    Cable for Internal Wiring of DY-SOFT Equipment

                    UL1430 UL Standard Lead Free Irradiated Cross-Linked PVC Cable

                    UL1672 UL Standard Lead Free Irradiated Cross-Linked Vinyl Double Insulated Wire

                    UL3265 UL Standard Lead Free Irradiated Cross-Linked Flame Retardant PE Cable

                    CE-362 Power Supply Cable

                    CE-362SB Power Supply Cable

                    Days to Ship 8 Day(s) or more 8 Day(s) or more 12 Day(s) or more 8 Day(s) or more 8 Day(s) or more 8 Day(s) or more 8 Day(s) or more 10 Day(s) or more 10 Day(s) or more
                    Specifications
                        • c-UL
                        • VW-1
                        • ULAWM
                        • For Signal
                        • Sensor
                        • Strand Wire
                        • 300 V
                                    Conductor Cross Section(mm2)--0.085.52 ~ 56.57---0.5 ~ 500.5 ~ 6
                                    AWG size(AWG)24 ~ 2816 ~ 28281 ~ 1016 ~ 2616 ~ 2222 ~ 281 ~ 2010 ~ 20
                                    Sheath (outer coating) colorBlack / Gray / White / Brown / Red / Orange / Yellow / Green / Blue / PurpleBlack / White / Red / Yellow / Green / BlueOtherBlack / OtherBlack / Gray / White / Brown / Red / Orange / Yellow / Green / Blue / Purple / OtherBlack / White / RedBlack / Gray / White / Brown / Red / Orange / Yellow / Green / Blue / PurpleGrayGray
                                    Rated Voltage--300V600V---600V600V
                                    Properties---Oil Resistance / Heat-Resistance-Abrasion Resistance-Oil Resistance / Heat-ResistanceOil Resistance / Heat-Resistance
                                    Overall Length(m)610305 ~ 61010 ~ 3051 ~ 100305 ~ 610305 ~ 61061010 ~ 10010 ~ 100
                                    Finished outer diameter(mm)0.88 ~ 1.111.2 ~ 2.351.185.4 ~ 15.61.48 ~ 2.532.68 ~ 3.450.98 ~ 1.366.2 ~ 388.5 ~ 20.5
                                    Representative StandardULULULULULULULULUL
                                    Insulation body materialsPVC (Polyvinyl Chloride)Other--PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)OtherOtherOther
                                    ShieldNANANANANANANANAAvailable
                                    Logarithm---------
                                    Sheath (outer coating) material--PVC (Polyvinyl Chloride)--PVC (Polyvinyl Chloride)-OtherOther

                                    Loading...

                                    1. 1