(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Pembayaran dengan kartu kredit untuk sementara tidak tersedia karena kendala sistem. Sementara waktu Anda dapat meggunakan metode Pembayaran di Muka atau QRIS. Untuk informasi lebih lanjut, silakan hubungi Customer Service : TEL: 021-8984-0008 E-mail: cs@misumi.co.id. WA: 08118984008. Kami mohon maaf atas ketidaknyamanan yang terjadi.
    Credit card payments are temporarily unavailable due to system issues. Meanwhile, you can use the Advance Payment method or QRIS. For further information, please contact Customer Service: TEL: 021-8984-0008 E-mail: cs@misumi.co.id. WA: 08118984008. We apologize for any inconvenience caused.
  • Sehubungan dengan adanya Peraturan Baru Kementerian Perdagangan No.36 Tahun 2023 tentang Pembatasan Impor Barang, MISUMI Indonesia melakukan tindakan pencegahan. Lihat informasi detailnya di sini
    Due to New Regulation of Ministry Of Trade No.36 of 2023 concerning retrictions on imports of goods, MISUMI Indonesia do precautions measure. See detail information here
  • Nomor telepon alternatif Kontak Layanan Pelanggan : 021-29182911| 021-29182991 | 021-29182997 | 021-29182998
    Alternative telephone number Contact Customer Service: 021-29182911 | 021-29182991 | 021-29182997 | 021-29182998

Control/Instrumentation Cables(Logarithm:1P)

Control and instrumentation cables are used for device controls and signal transmissions to and from terminal devices. Control cables are mainly used to control devices in plants and factories. For this reason, insulated vinyl sheath cables with PVC and polyethylene insulation are usually used for their highly flame retardant properties and excellent oil resistance, weather resistance and water resistance. Instrumentation cables are used in a wide range of applications including transmitting computer signals, electronic controls for industrial equipment, etc. Insulated vinyl sheath cables with polyethylene insulators are often used for their capacitance and noise reduction characteristics. The cables are selected for length and number of pairs, but other specific properties should also be considered, such as abrasion resistance and chemical resistance.
Days to Ship
  • All
  • 8 Day(s) or Less
  • 10 Day(s) or Less
  • 11 Day(s) or Less
  • 12 Day(s) or Less
  • 14 Day(s) or Less
  • 15 Day(s) or Less
  • 16 Day(s) or Less
  1. 1
Brand
Product Series
Days to Ship
Overall Length(m)
Specified Length(m)
Conductor Cross Section(mm2)
AWG size(AWG)
Number Of Cores(Core)
Logarithm
Finished outer diameter(mm)
Rated Voltage
Shield
Properties
Representative Standard
Sheath (outer coating) color
Grounding Wire
Sheath (outer coating) material
Insulation body materials

    KPEV-SBT Series

      Polyethylene Insulation Vinyl Sheath Instrumentation Cable J-KNPEV-SB

        UL Listed Unshielded Instrumentation Cable

          Twisted Pair Instrumentation Cable

            BIOS Highly Flame Retardant NEC Standard Cable (Shielded)

              KVC-36SBT

                KFPEV-SB Cable for Light Electrical Appliances and Instrumentation

                  BIO Highly Flame Retardant NEC Standard Cable (Non-Shield)

                    FCPEV Communication Cable

                      CL2/2464-3599-DS LF

                        Compensating Conductor

                          FCPEV (CU) Communication Cable

                          Brand

                          NAGAOKA ELECTRIC WIRE

                          NIHON ELECTRIC WIRE & CABLE

                          TACHII ELECTRIC WIRE

                          TACHII ELECTRIC WIRE

                          BANDO DENSEN

                          KURAMO ELECTRIC

                          FUJI ELECTRIC CABLE

                          BANDO DENSEN

                          FUJIKURA DIA CABLE

                          TAIYO CABLETEC

                          NINOMIYA ELECTRIC WIRE

                          FUJIKURA DIA CABLE

                          Product Series

                          KPEV-SBT Series

                          Polyethylene Insulation Vinyl Sheath Instrumentation Cable J-KNPEV-SB

                          UL Listed Unshielded Instrumentation Cable

                          Twisted Pair Instrumentation Cable

                          BIOS Highly Flame Retardant NEC Standard Cable (Shielded)

                          KVC-36SBT

                          KFPEV-SB Cable for Light Electrical Appliances and Instrumentation

                          BIO Highly Flame Retardant NEC Standard Cable (Non-Shield)

                          FCPEV Communication Cable

                          CL2/2464-3599-DS LF

                          Compensating Conductor

                          FCPEV (CU) Communication Cable

                          Days to Ship 11 Day(s) or more 10 Day(s) or more 8 Day(s) or more 8 Day(s) or more 8 Day(s) or more 12 Day(s) or more 12 Day(s) or more 8 Day(s) or more 11 Day(s) or more 11 Day(s) or more 8 Day(s) or more 11 Day(s) or more
                          Overall Length(m)1 ~ 1001 ~ 1001 ~ 1001 ~ 1001 ~ 1001 ~ 100-1 ~ 100500 ~ 10001 ~ 10020 ~ 100500 ~ 1000
                          Specified Length(m)------100-----
                          Conductor Cross Section(mm2)0.3 ~ 1.250.2 ~ 20.22 ~ 0.540.2 ~ 0.5-0.50.5 ~ 1.25--0.204 ~ 0.8230.5 ~ 1.3-
                          AWG size(AWG)16 ~ 2214 ~ 2420 ~ 2420 ~ 2420 ~ 242016 ~ 2020 ~ 24-18 ~ 24--
                          Number Of Cores(Core)2222-22-2-22
                          Logarithm1P1P1P1P1P1P1P1P1P1P1P1P
                          Finished outer diameter(mm)5.7 ~ 8.25.5 ~ 9.54 ~ 54.6 ~ 6.14.7 ~ 5.84.87 ~ 8.54.1 ~ 5.15 ~ 75.1 ~ 7.53.1x5.4 ~ 4.4x7.17
                          Rated VoltageOther-300VOther300VFor Low Current Circuits-300VOtherFor Low Current Circuits-Other
                          ShieldAvailableAvailableNAAvailableAvailableAvailableAvailableNAAvailableAvailableNAAvailable
                          Properties-Oil Resistance / Heat-ResistanceOil Resistance / Heat-ResistanceOil Resistance / Heat-ResistanceHeat-ResistanceOil Resistance-Heat-ResistanceWeatherproofOil Resistance / Heat-Resistance-Weatherproof
                          Representative Standard--UL / CSA(c-UL)UL / CSA(c-UL)UL / CSA(c-UL)UL / CSA(c-UL)-UL / CSA(c-UL)-UL / CSA(c-UL)--
                          Sheath (outer coating) colorBlackBlackBlackGrayBlackBlackBlackBlackBlackBlackBlack / Yellow / BlueBlack
                          Grounding WireOtherNANAOther-OtherNA-OtherNA-Other
                          Sheath (outer coating) materialOther-PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride) / OtherPVC (Polyvinyl Chloride)
                          Insulation body materialsOtherPolyethylene-BasedPVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)Polyethylene-BasedPVC (Polyvinyl Chloride)Polyethylene-BasedPolyethylene-BasedPVC (Polyvinyl Chloride) / OtherPolyethylene-Based