(!) Since support from Microsoft will end on January 14, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Penggunaan Window 7 tidak direkomendasikan pada website ini mulai tanggal 15 Desember 2019 dikarenakan support Windows 7 akan dihentikan Microsoft pada 14 Januari 2020.

  • Nomor telepon alternatif Kontak Layanan Pelanggan : 021-29182911| 021-29182991 | 021-29182997 | 021-29182998
    Alternative telephone number Contact Customer Service: 021-29182911 | 021-29182991 | 021-29182997 | 021-29182998

Emergency Alarm Cables

Fire alarm cables are used for applications such as fire protection equipment and alarm wiring. Cables for low power circuits using 60 V or less that do not require heat resistance are used for the wiring of devices such as interphone circuits, display wiring, bell wiring and earth leakage fire alarms. Flame-retardant cables with fire spread prevention properties do not generate much smoke in a fire and are used mainly for halogen-free eco-cables that do not generate toxic gases such as hydrogen halide gas or corrosive gas. Each type has heat-resistant layers and insulators coated with cross-linked polyethylene or heat-resistant polyethylene sheaths. A wide range of products are available that make work safer and easier, including types that enable open wiring through a staple stop method, and types with color-coded core wire identification to prevent miswiring.
Days to Ship
  • All
  • 9 Day(s) or Less
  • 10 Day(s) or Less
  • 11 Day(s) or Less
  • 13 Day(s) or Less
  • 58 Day(s) or Less
  1. 1
Brand
Product Series
Days to Ship
Overall Length(m)
Specified Length(m)
Conductor Cross Section(mm2)
AWG size(AWG)
Number Of Cores(Core)
Rated Voltage
Shield
Properties
Sheath (outer coating) color
Grounding Wire
Sheath (outer coating) material
Insulation body materials

    HFA Heat Resistant Wire for Small Force Circuits

      Heat Resistant Wire APK Series (with Shield)

        Communications Cable - FAP

          Polyethylene Insulation Cable for FA Alarms

            HFA-20 Heat Resistant Cable for High Frequency

              NH-HFA High Flame-Retardancy Halogen-Free Heat-Resistant Wire for Low Power Circuits

                Polyethylene Insulation Cable for Alarms NP

                  Heat Resistant Cable for Fire Services N-300

                    HP Heat-Resistant Cable for Fire Alarm Circuits

                      KRF Heat Resistant Wire for Fire Services

                        Heat Resistant Wire APK Series

                          Heat Resistant Wire EM-APK Series

                          Brand

                          FUJI ELECTRIC CABLE

                          KAYODENSEN

                          FUJI ELECTRIC WIRE INDUSTRIES

                          FUJI ELECTRIC CABLE

                          FUJI ELECTRIC CABLE

                          FUJI ELECTRIC CABLE

                          NIHON ELECTRIC WIRE & CABLE

                          NIHON ELECTRIC WIRE & CABLE

                          FUJIKURA DIA CABLE

                          KANZACC

                          KAYODENSEN

                          KAYODENSEN

                          Product Series

                          HFA Heat Resistant Wire for Small Force Circuits

                          Heat Resistant Wire APK Series (with Shield)

                          Communications Cable - FAP

                          Polyethylene Insulation Cable for FA Alarms

                          HFA-20 Heat Resistant Cable for High Frequency

                          NH-HFA High Flame-Retardancy Halogen-Free Heat-Resistant Wire for Low Power Circuits

                          Polyethylene Insulation Cable for Alarms NP

                          Heat Resistant Cable for Fire Services N-300

                          HP Heat-Resistant Cable for Fire Alarm Circuits

                          KRF Heat Resistant Wire for Fire Services

                          Heat Resistant Wire APK Series

                          Heat Resistant Wire EM-APK Series

                          Days to Ship 11 Day(s) or more 13 Day(s) or more 13 Day(s) or more 9 Day(s) or more 13 Day(s) or more 13 Day(s) or more 9 Day(s) or more 9 Day(s) or more 13 Day(s) or more 13 Day(s) or more 11 Day(s) or more 13 Day(s) or more
                          Overall Length(m)-1 ~ 200200---1 ~ 2007 ~ 20020010 ~ 2001 ~ 2001 ~ 200
                          Specified Length(m)10 ~ 200--10 ~ 200100100 ~ 200------
                          Conductor Cross Section(mm2)-20.9 ~ 1.2----1.25 ~ 2--1.25 ~ 2-
                          AWG size(AWG)-------14 ~ 16----
                          Number Of Cores(Core)2 ~ 1004 ~ 102 ~ 42 ~ 1002 ~ 62 ~ 202 ~ 1002 ~ 1002 ~ 1002 ~ 1001 ~ 602 ~ 20
                          Rated VoltageOther-OtherOtherOtherOther--Other---
                          ShieldNAAvailableNANAAvailableNANAAvailable / NANANANANA
                          PropertiesHeat-ResistanceHeat-Resistance--Heat-ResistanceHeat-Resistance-Heat-ResistanceHeat-ResistanceHeat-ResistanceHeat-ResistanceHeat-Resistance
                          Sheath (outer coating) colorGrayGrayOtherGray / OtherGrayBlackGray / OtherGray / OtherGray-GrayBlack
                          Grounding WireNANANANANANANANANANANANA
                          Sheath (outer coating) materialOtherPVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)OtherOtherOtherOther-PVC (Polyvinyl Chloride)OtherPVC (Polyvinyl Chloride)Polyester-Based
                          Insulation body materialsPolyethylene-BasedPolyethylene-BasedPolyethylene-BasedPolyethylene-BasedPolyethylene-BasedPolyethylene-BasedPolyethylene-BasedPolyethylene-Based-Polyethylene-BasedPolyethylene-BasedPolyethylene-Based