5-Port Solenoid Valve With Single/Double Switch Function

5-Port Solenoid Valve With Single/Double Switch Function
  • Economy

Choose between single and double solenoids by using a switch.
[Features]
· Rated voltage: 24 V DC.
· Pilot valve option: Standard (0.7 MPa), Quick response (0.7 MPa).
· Back-pressure check valve (built-in valve type): Standard, built-in.
· Coil type: Standard, with power-saving circuit (continuous duty type).
· Common specifications: Non-polar, positive common, negative common.

(i)Caution

  • Refer to the manufacturer's catalog for specification and material details.
  • Product images may be representative images. Refer to the manufacturer's catalog for shape details.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

5-Port Solenoid Valve With Single / Double Switching Function Specifications

5-Port Solenoid Valve With Single / Double Switching Function external appearance

5-Port Solenoid Valve With Single / Double Switching Function external appearance

  • Valve type: Pilot operated 2-position 5-port solenoid valve
  • Valve construction: Rubber seal
  • Switching method: Single/double switching type
  • Piping: Side ported / bottom ported, top ported
  • Manual: Non-locking push type, push-turn locking slotted type, push-turn locking lever type, sliding lock type

Base mounted valve weight

  • SY3(S, D)00: 84.5 g
  • SY5(S, D)00: 95.3 g

Body ported valve weight

  • SY3S30 (port size: C4): 87.9 g
  • SY3S30 (piping connection port diameter: C6): 90.9 g
  • SY5D30 (piping connection port diameter: C8): 112.3 g

*This product is the valve unit only. The manifold is not included.

Actuation switch

Single solenoid

Single solenoid

Double solenoid

Double solenoid

Switching between single specification and double specification (Left: single specification / actuation switch recessed, Right: double specification / actuation switch protruding)

Switching between single specification and double specification (Left: single specification / actuation switch recessed, Right: double specification / actuation switch protruding)

Usage Precautions

  • 1.When using a single specification valve as a double specification, turn the actuation switch with a precision screwdriver so that the slot on the actuation switch is in the "S" position as shown in the drawing.
  • 2.When using a double specification valve as a single specification, press the actuation switch and then rotate it counterclockwise. The single specification will not malfunction even if the 2 (B) side is operated manually.
  • 3.Do not energize the solenoid on both sides simultaneously.
  • 4. Be aware that actuator ejection may occur if the actuation switch of the double specification is operated when the main valve position is connecting 1 (P) → 4 (A), as the main valve position will change to connecting 1 (P) → 2 (B).
  • 5.See the manufacturer's catalog for details regarding the electric circuitry of models with indicator light / surge voltage suppressor.
  • 6.For manifold piping specification, select double piping specification.
  • 7.When turning the conversion switch, do not apply more torque than required. (Recommended value: less than 0.05 N⋅m)

Outline dimensional drawing

Side/bottom ported type

 

(Unit: mm)

 

SY3(S, D)00 dimensional drawing

SY3(S, D)00 dimensional drawing

 

(Unit: mm)

 

SY5(S, D)00 dimensional drawing

SY5(S, D)00 dimensional drawing

Top ported type

 

(Unit: mm)

 

SY3(S, D)30 dimensional drawing

SY3(S, D)30 dimensional drawing

 

(Unit: mm)

 

SY5(S, D)30 dimensional drawing

SY5(S, D)30 dimensional drawing

*Dimensional drawings are of a representative product.

Precautions

  • *Product images may be representative images.
  • *See the manufacturer's catalog for product information other than the above.
Part Number
SY5D00-5U1
SY5D00-5UF1
SY5D00-5Z1
SY5D00BT-5Z1
SY5D00BT-5ZD1
SY5D00BT-5ZE1
SY5D00BT-5ZF1
SY5D30T-5ZF1-C8
SY5S00-5U1
SY5S00-5UE1
SY5S00-5UF1
SY5S00-5Z1
SY5S00B-5Z1
SY5S00BT-5Z1
SY5S00BT-5ZD1
SY5S00BT-5ZE1
SY5S00BT-5ZF1
SY5S00HBT-5Z1
SY5S00T-5ZF1
Part NumberMinimum order quantityVolume DiscountDays to ShipNumber of Solenoids Status at Power Off Pipe Port Type Applicable Cylinder Dia.
(Ø)
Plumbing Connecting Tube Diameter Coil specifications Manual Indicator light / Surge voltage suppressor Valve specifications Functions Back-pressure check valve Common specifications
1 Piece(s) Quote DoubleSelf-Retaining-125 or lessSub-Base Plumbing-StandardNon-locking, push typeWith indicator light and surge voltage suppressor-Standard (0.7 MPa)StandardNon-polarized
1 Piece(s) Quote DoubleSelf-Retaining-125 or lessSub-Base Plumbing-StandardSliding type locking systemWith indicator light and surge voltage suppressor-Standard (0.7 MPa)StandardNon-polarized
1 Piece(s) Quote DoubleSelf-Retaining-125 or lessSub-Base Plumbing-StandardNon-locking, push typeWith indicator light and surge voltage suppressor-Standard (0.7 MPa)StandardPositive common
1 Piece(s) Quote DoubleSelf-Retaining-125 or lessSub-Base Plumbing-With energy-saving circuit (long time continuous energizing type)Non-locking, push typeWith indicator light and surge voltage suppressor-Quick response (0.7 MPa)StandardPositive common
1 Piece(s) Quote DoubleSelf-Retaining-125 or lessSub-Base Plumbing-With energy-saving circuit (long time continuous energizing type)Push-turn locking screwdriver-operated typeWith indicator light and surge voltage suppressor-Quick response (0.7 MPa)StandardPositive common
1 Piece(s) Quote DoubleSelf-Retaining-125 or lessSub-Base Plumbing-With energy-saving circuit (long time continuous energizing type)Push-turn locking hand-operated typeWith indicator light and surge voltage suppressor-Quick response (0.7 MPa)StandardPositive common
1 Piece(s) Quote DoubleSelf-Retaining-125 or lessSub-Base Plumbing-With energy-saving circuit (long time continuous energizing type)Sliding type locking systemWith indicator light and surge voltage suppressor-Quick response (0.7 MPa)StandardPositive common
1 Piece(s) Quote DoubleSelf-RetainingOne-Touch Plumbing125 or lessDirect PlumbingØ8With energy-saving circuit (long time continuous energizing type)Sliding type locking systemWith indicator light and surge voltage suppressor-Standard (0.7 MPa)StandardPositive common
1 Piece(s) Quote [Single] SingleSelf-Recovery (Pressure Differential Return)-125 or lessSub-Base Plumbing-StandardNon-locking, push typeWith indicator light and surge voltage suppressor-Standard (0.7 MPa)StandardNon-polarized
1 Piece(s) 15 Day(s) [Single] SingleSelf-Recovery (Pressure Differential Return)-125 or lessSub-Base Plumbing-StandardPush-turn locking hand-operated typeWith indicator light and surge voltage suppressor (non-polar type)SY5000Standard (0.7 MPa)StandardNon-polarized
1 Piece(s) Quote [Single] SingleSelf-Recovery (Pressure Differential Return)-125 or lessSub-Base Plumbing-StandardSliding type locking systemWith indicator light and surge voltage suppressor-Standard (0.7 MPa)StandardNon-polarized
1 Piece(s) Quote [Single] SingleSelf-Recovery (Pressure Differential Return)-125 or lessSub-Base Plumbing-StandardNon-locking, push typeWith indicator light and surge voltage suppressor-Standard (0.7 MPa)StandardPositive common
1 Piece(s) Quote [Single] SingleSelf-Recovery (Pressure Differential Return)-125 or lessSub-Base Plumbing-StandardNon-locking, push typeWith indicator light and surge voltage suppressor-Quick response (0.7 MPa)StandardPositive common
1 Piece(s) Quote [Single] SingleSelf-Recovery (Pressure Differential Return)-125 or lessSub-Base Plumbing-With energy-saving circuit (long time continuous energizing type)Non-locking, push typeWith indicator light and surge voltage suppressor-Quick response (0.7 MPa)StandardPositive common
1 Piece(s) Quote [Single] SingleSelf-Recovery (Pressure Differential Return)-125 or lessSub-Base Plumbing-With energy-saving circuit (long time continuous energizing type)Push-turn locking screwdriver-operated typeWith indicator light and surge voltage suppressor-Quick response (0.7 MPa)StandardPositive common
1 Piece(s) Quote [Single] SingleSelf-Recovery (Pressure Differential Return)-125 or lessSub-Base Plumbing-With energy-saving circuit (long time continuous energizing type)Push-turn locking hand-operated typeWith indicator light and surge voltage suppressor-Quick response (0.7 MPa)StandardPositive common
1 Piece(s) Quote [Single] SingleSelf-Recovery (Pressure Differential Return)-125 or lessSub-Base Plumbing-With energy-saving circuit (long time continuous energizing type)Sliding type locking systemWith indicator light and surge voltage suppressor-Quick response (0.7 MPa)StandardPositive common
1 Piece(s) Quote [Single] SingleSelf-Recovery (Pressure Differential Return)-125 or lessSub-Base Plumbing-With energy-saving circuit (long time continuous energizing type)Non-locking, push typeWith indicator light and surge voltage suppressor-Quick response (0.7 MPa)Built-in typePositive common
1 Piece(s) Quote [Single] SingleSelf-Recovery (Pressure Differential Return)-125 or lessSub-Base Plumbing-With energy-saving circuit (long time continuous energizing type)Sliding type locking systemWith indicator light and surge voltage suppressor-Standard (0.7 MPa)StandardPositive common

Loading...

  1. 1

Basic Information

Type Solenoid Valves Application Unit for Manifold Mounting Number of Ports 5-Port Valve
Mounting Orientation Manifold Base Specifications Standard Switching Type 2-Position Exhaust
Voltage DC24V Driving Type Pilot Type Spool Seal Type Soft Seal
Pressure Rating(MPa) 0.5 Pilot Air Supply Internal Mounting screw type Small cross pan head screw

Tech Support