(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Sehubungan dengan adanya Peraturan Baru Kementerian Perdagangan No.36 Tahun 2023 tentang Pembatasan Impor Barang, MISUMI Indonesia melakukan tindakan pencegahan. Lihat informasi detailnya di sini
    Due to New Regulation of Ministry Of Trade No.36 of 2023 concerning retrictions on imports of goods, MISUMI Indonesia do precautions measure. See detail information here
  • Nomor telepon alternatif Kontak Layanan Pelanggan : 021-29182911| 021-29182991 | 021-29182997 | 021-29182998
    Alternative telephone number Contact Customer Service: 021-29182911 | 021-29182991 | 021-29182997 | 021-29182998

Motor Operated Auto Drain ADM200 Series

Motor Operated Auto Drain ADM200 Series

Drain that reliably discharges high-viscosity condensate
[Features]
・ It is resistant to dust and high-viscosity condensates, and opens and closes the valve securely to discharge the condensate.
・ Large condensate discharge capacity
・ The discharge port can be enlarged and a large amount of condensate can be discharged with a single operation.
・ Condensate does not remain inside the tank or piping, preventing rust and foreign object generated by drying the condensate from adversely affecting downstream equipment.
・ Low power consumption / 4 W
・ Long piping is also possible for the discharge port.
・ It can be attached directly to the compressor.

(i)Caution

  • See catalog for specification details.
  • Product images may be representative images. Refer to the catalog for details.

PDF

Motor Operated Auto Drain ADM200 Specifications

Mounting example

Mounting example

ModelADM200-□□-□
FluidAir
Maximum operating pressure1.0 MPa
Proof pressure1.5 MPa
Ambient and fluid temperature-5 to +60°C (no freezing)
Operating cycle*1 cycle in 1 minute (Standard)
Operating time2 sec./cycle (Standard)
Power Supply100, 200 V AC 50/60 Hz, other
Power consumption4 W
Connection port sizeIN: 3/8, 1/2 
OUT: 3/8
Weight550 g

*If the operating cycle is 2 times in 1 minute (op. time 2 sec. × 2), the operating time is 4 sec. each minute.

Voltage

  • 100 V AC 50 Hz/60 Hz
  • 200 V AC 50 Hz/60 Hz
  • 240 V AC 50 Hz/60 Hz
  • 110 V AC 50 Hz/60 Hz
  • 220 V AC 50 Hz/60 Hz
  • 24 V DC
  • 12 V DC

Operating Time / Applicable Compressor

  • 2 sec/min. (1 time/min.) / 3.7 to 37 kW
  • 4 sec/min. (2 times/min.) / 37 to 75 kW
  • 6 sec/min. (3 times/min.) / 75 to 110 kW
  • 8 sec/min. (4 times/min.) / 220 to 370 kW

Thread type

  • Rc
  • NPT
  • G

Port size

SymbolINOUT
033/83/8
041/23/8

 

(Unit: mm)

 

ADM200 structural and dimensional drawings

ADM200 structural and dimensional drawings

Component Parts

  1. 1.: Body
  2. 2.: Cap
  • Material: die-cast aluminum
  • Remarks: chromate treatment

Replacement Parts

NumberPart nameMaterialPart number
3Motor-Voltage
D126J45-29 (100 V AC)
D126J45-31 (200 V AC)
D126J45-33 (240 V AC)
D126J45-30 (110 V AC)
D126J45-32 (220 V AC)
812PG-DC24V (24 V DC)
4CamCast steelOperating time
201324 (Nil)
201325 (4)
201326 (6)
201327 (8)
5Valve assemblyBrass, NBR20137-1A
6O-ringNBRKA01323
Part Number
ADM200-N031
ADM200-N031-4
ADM200-N032
ADM200-N032-4
ADM200-N032-6
ADM200-N034
ADM200-N034-4
ADM200-N036
ADM200-N041
ADM200-N041-6
ADM200-N041-8
ADM200-N042-4
ADM200-N042-6
ADM200-N043
ADM200-N044-4
ADM200-N044-8
ADM200-N045
ADM200-N045-4
ADM200-N045-8
ADM200-N046
ADM200-N046-6
Part NumberMinimum order quantityVolume DiscountDays to ShipPower Supply Voltage Inlet Connection Type Inlet Connection Screw Nominal Outlet Connection Type Max. Operating Pressure
(MPa)
Operating Time/Applicable Compressor
1 Piece(s) Quote [AC100V] AC100V 50/60HzNPT[3/8B] 3/8NPT12 sec/min. (1 time/min.) / 3.7 to 37 kW
1 Piece(s) Quote [AC100V] AC100V 50/60HzNPT[3/8B] 3/8NPT14 sec/min. (2 times/min.) / 37 to 75 kW
1 Piece(s) Quote [AC200V] AC200V 50/60HzNPT[3/8B] 3/8NPT12 sec/min. (1 time/min.) / 3.7 to 37 kW
1 Piece(s) Quote [AC200V] AC200V 50/60HzNPT[3/8B] 3/8NPT14 sec/min. (2 times/min.) / 37 to 75 kW
1 Piece(s) Quote [AC200V] AC200V 50/60HzNPT[3/8B] 3/8NPT16 sec/min. (3 times/min.) / 75 to 110 kW
1 Piece(s) Quote [AC110V] AC110V 50/60HzNPT[3/8B] 3/8NPT12 sec/min. (1 time/min.) / 3.7 to 37 kW
1 Piece(s) Quote [AC110V] AC110V 50/60HzNPT[3/8B] 3/8NPT14 sec/min. (2 times/min.) / 37 to 75 kW
1 Piece(s) Quote DC24VNPT[3/8B] 3/8NPT12 sec/min. (1 time/min.) / 3.7 to 37 kW
1 Piece(s) 31 Day(s) [AC100V] AC100V 50/60HzNPT[1/2B] 1/2NPT12 sec/min. (1 time/min.) / 3.7 to 37 kW
1 Piece(s) 31 Day(s) [AC100V] AC100V 50/60HzNPT[1/2B] 1/2NPT16 sec/min. (3 times/min.) / 75 to 110 kW
1 Piece(s) Quote [AC100V] AC100V 50/60HzNPT[1/2B] 1/2NPT18 sec/min. (4 time/min.) / 220 to 370 kW
1 Piece(s) Quote [AC200V] AC200V 50/60HzNPT[1/2B] 1/2NPT14 sec/min. (2 times/min.) / 37 to 75 kW
1 Piece(s) Quote [AC200V] AC200V 50/60HzNPT[1/2B] 1/2NPT16 sec/min. (3 times/min.) / 75 to 110 kW
1 Piece(s) Quote [AC240V] AC240V 50/60HzNPT[1/2B] 1/2NPT-2 seconds/minute (1 operation / minute) / 3.7 to 37 kW
1 Piece(s) Quote [AC110V] AC110V 50/60HzNPT[1/2B] 1/2NPT14 sec/min. (2 times/min.) / 37 to 75 kW
1 Piece(s) Quote [AC110V] AC110V 50/60HzNPT[1/2B] 1/2NPT18 sec/min. (4 time/min.) / 220 to 370 kW
1 Piece(s) 31 Day(s) [AC220V] AC220V 50/60HzNPT[1/2B] 1/2NPT12 sec/min. (1 time/min.) / 3.7 to 37 kW
1 Piece(s) 31 Day(s) [AC220V] AC220V 50/60HzNPT[1/2B] 1/2NPT14 sec/min. (2 times/min.) / 37 to 75 kW
1 Piece(s) 31 Day(s) [AC220V] AC220V 50/60HzNPT[1/2B] 1/2NPT18 sec/min. (4 time/min.) / 220 to 370 kW
1 Piece(s) 31 Day(s) DC24VNPT[1/2B] 1/2NPT12 sec/min. (1 time/min.) / 3.7 to 37 kW
1 Piece(s) Quote DC24VNPT[1/2B] 1/2NPT16 sec/min. (3 times/min.) / 75 to 110 kW

Loading...

  1. 1

Basic Information

Type Drain Discharge Apparatus Drain Discharge Automatic ejection Drain Discharge Operating Method Compressor Interlocking when ON / Compressor Interlocking when OFF / Constant Time
Outlet Screw Nominal 3/8

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:021-8990-4102 / FAX:021-8990-5803
8:30am - 5:30pm (Monday - Friday)