(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Sehubungan dengan adanya Peraturan Baru Kementerian Perdagangan No.36 Tahun 2023 tentang Pembatasan Impor Barang, MISUMI Indonesia melakukan tindakan pencegahan. Lihat informasi detailnya di sini
    Due to New Regulation of Ministry Of Trade No.36 of 2023 concerning retrictions on imports of goods, MISUMI Indonesia do precautions measure. See detail information here
  • Nomor telepon alternatif Kontak Layanan Pelanggan : 021-29182911| 021-29182991 | 021-29182997 | 021-29182998
    Alternative telephone number Contact Customer Service: 021-29182911 | 021-29182991 | 021-29182997 | 021-29182998

Solid State Contactors US-H Series

Solid State Contactor US-H Series Features

  • Optimal for injection molding machines, semiconductor production equipment, and other uses with high-frequency heater switching.
  • The load current switching operation is performed by a semiconductor switching element, and as there are no mechanical parts, a long life with highly frequent switching can be achieved.
  • No mechanical moving parts or abrading parts, and therefore no abrasion dust or contact consumption dust, resulting in clean, noiseless, comfortable use.
  • Can be used at 24 to 480 V AC, a wide voltage range for the main circuit.
  • Operation indicator lamp on the front surface allows users to see the operating voltage input status at a glance.
  • Can select control method suited for the applied load, such as a main circuit batch control product suited for three-phase heater control (US-H□ type), or a main circuit individual control product suited for single-phase heater control (US-H□DD type).

Solid State Contactor US-H Series Specifications

Type
Name
StandardUS-H20US-H30US-H40US-H50US-H20DDUS-H30DDUS-H40DDUS-H50DD
IEC 35 mm Rail MountingUS-H20RMUS-H30RM--US-H20DDRMUS-H30DDRM--
Width Dimension DecreasedUS-H20UFUS-H30UF--US-H20DDUFUS-H30DDUF--
Rating
Rated Operating Current
(-10 To 40°C)
JEM (AC-1 Class)20 A30 A40 A50 A20 A30 A40 A50 A
IEC (AC-51 Class)20 A30 A40 A50 A20 A30 A40 A50 A
Applied Heater Capacity
(-10 To 40°C)
1 ø 200 V4 kW6 kW8 kW10 kW4 kW6 kW8 kW10 kW
3 Ø 200 V6.9 kW10.3 kW13.8 kW17.3 kW----
1 ø 400 V8 kW12 kW16 kW20 kW8 kW12 kW16 kW20 kW
3 Ø 400 V13.8 kW20.7 kW27.7 kW34.6 kW----
Minimum Load Current0.3 A
Main
Circuit
Specifications

Main Circuit Control MethodBatch controlIndividual control
Rated Operating Voltage24 to 480 V AC 50/60 Hz
Operating Voltage Range20 to 528 V AC
Rated Insulation Voltage500 V AC
Voltage Drop Upon Closing1.8 V (when energized with rated current)
Leakage Current When ClosingMaximum 30 mA (480 V AC 60 Hz)
Surge On Current
(60 Hz, Half-Wave 1 Cycle Wave Height Value)
330 A800 A1000 A1,300 A330 A800 A1000 A1,300 A
Tolerance I2t(A2s)4502,6004,1007,0004502,6004,1007,000
Trigger MethodZero voltage trigger method
Closing And Breaking Current Capacity28 A42 A56 A70 A28 A42 A56 A70 A
Operation
Circuit
Specifications

Rated Operating Voltage12 to 24 V DC (Voltage ripple rate 10% or less)
Operating Voltage Fluctuation Range85 to 110% of rated operating voltage
Operation Circuit Maximum Applied Voltage26.4 V DC
Operation Circuit Input Voltage10 mA or less (12 to 24 V DC)
Input Impedance1.2 to 2.4 kΩ
Operating Voltage9 V DC or less
Open Circuit Voltage3 V DC or more
Response TimeMaximum (1 ms+1/2 cycle)
Operating DisplayLED indicator lamp (Lights when applying operating voltage)
Common
Specifications

Withstand Voltage2.5 kV
Insulation Resistance100 MΩ
Rated Impulse Withstand Voltage6 kV
Ambient Operating Temperature-10 To 60°C (At 40°C Or Higher, Use Reduced Current)
Relative Temperature45% to 85% RH
Altitude2,000 m or less
Vibration Resistance10 to 55 Hz 19.6 m/s2
Shock Resistance98 m/s2
  • Note: We also have the US-H□HZ type, which has no cooling fins.
  • Note: The US-H□ type is a solid state conductor for heater load. Please do not use this for motor load.
Part Number
US-H20
US-H20DDHZ
US-H20HZ
US-H20RM
US-H20UF
US-H30
US-H30DDHZ
US-H30DDUF
US-H30HZ
US-H30RM
US-H30UF
US-H40
US-H40DD
US-H40DDHZ
US-H50
US-H50DD
US-H50DDHZ
Part NumberMinimum order quantityVolume DiscountDays to ShipDimension length
(mm)
Dimension width
(mm)
Dimension thickness
(mm)
Specifications Rated current used
(A)
Circuit control method
1 Piece(s) Same day 1009097Standard Form20Batch control
1 Piece(s) Quote 5844.538No cooling fins20Individual control
1 Piece(s) Quote 5844.538No cooling fins20Batch control
1 Piece(s) Quote 1009097Rail mount dedicated20Batch control
1 Piece(s) Quote 10045150Width dimension contraction accessory20Batch control
1 Piece(s) Quote 1009097Standard Form30Batch control
1 Piece(s) Quote 5844.538No cooling fins30Individual control
1 Piece(s) Quote 65100150Width dimension contraction accessory30Individual control
1 Piece(s) Quote 5844.538No cooling fins30Batch control
1 Piece(s) Quote 1009097Rail mount dedicated30Batch control
1 Piece(s) Quote 65100150Width dimension contraction accessory30Batch control
1 Piece(s) Quote 120110125Standard Form40Batch control
1 Piece(s) Quote 120110125Standard Form40Individual control
1 Piece(s) Quote 5844.538No cooling fins40Individual control
1 Piece(s) Quote 120110125Standard Form50Batch control
1 Piece(s) Quote 120110125Standard Form50Individual control
1 Piece(s) Quote 5844.538No cooling fins50Individual control

Loading...

  1. 1
 

Basic Information

Operating Method Irreversible type Coil rated voltage(V) DC 12–24 Number of Poles 2
Representative Standard CE / UL / TUV / CSA Equipment Name Solid state contactor Finger protection/terminal cover NA