(!) Since support from Microsoft will end on January 14, 2020, Windows 7 will be excluded from the recommended environment from December 15th, 2019 on this site. Penggunaan Window 7 tidak direkomendasikan pada website ini mulai tanggal 15 Desember 2019 dikarenakan support Windows 7 akan dihentikan Microsoft pada 14 Januari 2020.

  • Fitur "Auto Translate" pada halaman eKatalog sementara ini tidak tersedia. Mohon maaf atas ketidaknyamanannya.
    Auto translation feature on our e-Catalog page is temporarily not available. We apologize for any inconvenience.
  • Sehubungan dengan wabah virus Corona (2019-nCoV), kami mohon maaf dikarenakan beberapa supplier harus berhenti beroperasi dan tingginya permintaan akan beberapa produk, hal ini akan mempengaruhi lead time beberapa produk menjadi lebih lama dari waktu standar.
    Regarding the Coronavirus (2019-nCoV) Pandemic, Some of supplier have to stop working to follow additional precautionary measures the virus and due to effect of high demand some product, it may cause some of product take longer than standard lead time.

Surface-mount Relay - G6L

Surface-mount Relay - G6L
  • On Sale Till 23/12/2020

[Features]
· An ultra-thin single pole flat relay with the lowest profile in its class.
· Requires approximately 20% less surface area for mounting and has approximately 64% the volume (compared to the manufacturer's G5V-1). This enables high-density mounting (width: 7.0 mm × length: 10.6 mm × height: 4.5 mm (SMD), 4.1 mm (TH)).
· High withstand voltage between coil-contacts of AC1,000V. Also boasts impulse voltage resistance of 1.5kV10 × 160 μs (FCCPart68 compliant).
· High withstand voltage between identical polarity contacts of 750V.
· Surface mounted types also available.
· The standard type is UL and CSA standard certified.
· Uses absolutely no lead.

PDF

Japanese Only

Surface Mount Relay G6L Series Specifications

Surface Mount Relay G6L: related images

Model G6L-1P outline drawing

Surface Mount Relay G6L: related images

Note: The general dimensional tolerance is ±0.3 mm.

Surface Mount Relay G6L: related images

The dimensional tolerance is ±0.1 mm.

Ratings

ItemsRated Current
(mA)
Coil Resistance
(Ω)
Operating Voltage
(V)
Release Voltage
(V)
Maximum Allowable Voltage
(V)
Power Consumption
(mW)
Rated Voltage (V)
DC536.0139.075% or Less10% or More150%Approx. 180
1215.0800.0

Note 1: The rated current and coil resistance are measured at a coil temperature of +23°C and a tolerance of ±10%.
Note 2: The operating characteristics are measured at a coil temperature of +23°C.
Note 3: The maximum allowable voltage is the maximum voltage that can be applied to a relay coil.
Note 4: Measurements for Turn ON/Turn OFF voltage are values measured using instantaneous changes in voltage (rectangular waves).

Performance

TypeSingle Stable Type
ModelModel G6L-1P
Contact Resistance *1100 mΩ or Less
Operating Time *25 ms or Less (Approx. 1.1 ms)
Turn OFF Time *25 ms or Less (Approx. 0.4 ms)
Insulation Resistance *31,000 MΩ or More (at 500 V DC)
Withstand VoltageBetween Coil and Contact1,000 V AC 50/60 Hz 1 min
Between Contacts of Same Polarity750 V AC 50/60 Hz 1 min
Impulse Withstand VoltageBetween Coil and Contact1,500 V 10 × 160 μs
VibrationDurability10 to 55 Hz Semi-Amplitude 1.65 mm (Double Amplitude 3.3 mm)
Malfunction10 to 55 Hz Semi-Amplitude 1.65 mm (Double Amplitude 3.3 mm)
Shock / ImpactDurability1,000 m/s2
Malfunction100 m/s2
DurabilityMechanical5,000,000 Times or More (Switching Frequency: 36,000 Times/h)
Electrical100,000 Times or More (Rated Load, Switching Frequency: 1,800 Times/h)
Failure Rate P Level (Reference Value *4)5 V DC, 1 mA
Ambient Operating Temperature-40 to +70°C (Assuming No Freezing or Condensation)
Operating Ambient Humidity5 to 85%RH
WeightApprox. 0.6 g

Note: The above values are the initial default values.
*1. Measurement conditions: 1 V DC 10 mA, voltage drop method.
*2. The values within ( ) are the actual values.
*3. Measurement conditions: Measuring the same spot for the withstand voltage items using a 500 V DC insulation resistance meter.
*4. This value is obtained with a switching frequency of 120 times/min. and a contact resistance failure value of 100 Ω.
These values may vary depending on switching frequency and operating conditions, meaning it is always recommended to double-check under actual load conditions.

  • *Refer to the catalog for other specifications.
Part Number
G6L-1P DC5
G6L-1P DC12
Part NumberVolume DiscountDays to ShipCoil rated voltage (DC)
(V)
Same day 5
Same day 12

Loading...

  1. 1
 

Basic Information

Application For Signals Contact Configuration 1a Latch function NA
Terminal shape For Circuit Boards Contact rated current (minimum value for AC and DC)(A) 0.3 Dimension height(mm) 4.1
Dimension width(mm) 10.6 Dimension depth(mm) 7 Classification Single stable shape
Protective Structure Plastic seal type Contact mechanism Crossbar twin Circuit Board Mounting Circuit Board Hole Insertion
AC rated load(V)/(A) AC125/0.3 DC rated load(V)/(A) DC24/1