(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • Sehubungan dengan adanya Peraturan Baru Kementerian Perdagangan No.36 Tahun 2023 tentang Pembatasan Impor Barang, MISUMI Indonesia melakukan tindakan pencegahan. Lihat informasi detailnya di sini
    Due to New Regulation of Ministry Of Trade No.36 of 2023 concerning retrictions on imports of goods, MISUMI Indonesia do precautions measure. See detail information here
  • Nomor telepon alternatif Kontak Layanan Pelanggan : 021-29182911| 021-29182991 | 021-29182997 | 021-29182998
    Alternative telephone number Contact Customer Service: 021-29182911 | 021-29182991 | 021-29182997 | 021-29182998

Solid State/Timer H3DS

Solid State/Timer H3DS
  • Volume Discount

DIN17.5 mm wide console incorporating a standard timer series

[Features]
· Huge reduction in inventory types by enabling AC/DC power sources (AC24 to 230V/DC24 to 48V).
· The eight operational modes (type H3DS-ML), and four operational modes (Type H3DS-SL) cover a variety of applications.
· Erroneous operation prevented by a dial/switch locking function.
· 0 Setting instantaneous output which facilitates sequence check.
· UL, CSA acquired, EN61812-1 compatible.
· Compatible with the CE mark.
· Conforms with the EMC standard EN61812-1, so can be used in an industrial environment but also in residential, sales and light industry.
· Cadmium free terminal is easy on the environment (AgNi connection point) relay employed.
· Name seals applied for use by specific preferred users.
· A terminal construction with secure screw fittings that prevents against hazardous contact (VDE0106/P100 compliant).

PDF

Japanese Only

Solid-State Timer Specifications

Solid-State Timer H3DS: related image

H3DS-ML external appearance

Solid-State Timer H3DS: related image

H3DS-SL external appearance

Solid-State Timer H3DS: related image

H3DS-AL external appearance

Solid-State Timer H3DS: related image

H3DS dimensional outline drawing, units: mm

Note 1. For terminal connections, use a single wire of 2.5 mm2 or less, or a bar terminal with an insulating sleeve. To ensure the withstand voltage after connection, set the length of the exposed conductive portion to be inserted into the terminal to 8 mm or less.
Note 2. Screw tightening torque
Recommended torque: 0.49 N·m
Maximum torque: 0.98 N·m max

Solid-State Timer H3DS: related image

Figure for Note 1.
For single wire of 2.5 mm2 or less

Solid-State Timer H3DS: related image

Figure for Note 1.
For bar terminal with insulating sleeve

Features

  • Sticker provided for easy timer identification by users.
  • Terminal structure with secure screw fittings that protects against hazardous contact (VDE0106/P100 compliant)
Power Supply Voltage24 to 230 V AC / 24 to 48 V DC, 50/60 Hz (DC power supply ripple is 20% or less)
Allowable Voltage Variation Range85 to 110% of rated voltage
Power Supply ResetMinimum power supply open time: 0.1 s
Recovery Voltage2.4 V AC/V DC or Less
Voltage InputH Level: 20.4 to 253 V AC / 20.4 to 52.8 V DC, L Level: 0 to 2.4 V AC / V DC
Power Consumption*1When 230 V AC: 32 VA max. / 3.0 W max. (approx. 30 VA / 2.7 W)
When 24 V DC: 0.7 W max. (approx. 0.6 W)
When 48 V DC: 1.4 W max. (approx. 1.3 W)
Control OutputContact output: 250 V AC 5 A resistive load (cosφ = 1), 250 V AC 1 A inductive load (cosφ = 0.3), 30 V DC 5 A resistive load *2
125 V DC 0.15 A max. resistive load, 125 V DC 0.1 A max. L/R = 7 ms
Minimum applied load: 5 V DC 10 mA (P level, reference)
Contact material: Ag alloy
Operating Temperature Range-10 to +55°C (No Freezing)
Storage Temperature Range-25 to +65℃ (No Freezing)
Ambient Operating Humidity35 to 85%

Note: Since there is an inrush current of approx. 0.5 A when using the power supply voltage at 24 V DC, caution is required when opening/closing the power supply of the timer body with a non-contact output such as a sensor, etc.

  • *1 Power consumption is for A mode and after time up. AC input is at 50 Hz.
    For the H3DS-ML type, this is the maximum when including the input circuit current consumption.
  • *2 The control output rating is for a discrete H3DS unit. When 2 or more are used side by side, see "Installation Pitch and Output Switching Capacity (Reference Values)" in the catalog.
  • *Refer to the catalog for specifications other than those listed above.
Part Number
H3DS-AL AC/DC
H3DS-ML AC/DC
H3DS-SL AC/DC
Part NumberMinimum order quantityVolume DiscountDays to ShipRoHS
1 Piece(s) Same day 10
1 Piece(s) Same day 10
1 Piece(s)Available 16 Day(s) or more -

Loading...

  1. 1
 

Basic Information

Type Timer Display method No display function Mounting Method DIN rail mount
Time specifications(s) 0.1s to 10h Power Supply Voltage AC/DC Output Method Relay
Dimension vertical(mm) 80 Dimension width(mm) 17.5 Dimension depth(mm) 73
Rated power supply voltage(V) AC24 to 230/DC24 to 48 Time ranges = N 7 range Contact Configuration Time Limit 1c

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:021-8990-4102 / FAX:021-8990-5803
8:30am - 5:30pm (Monday - Friday)