Temperature Sensors High Temperature K-Thermocouple

Temperature Sensors High Temperature K-Thermocouple

Click this image to zoom it.

Move the mouse over the image to zoom

  • Volume Discount

Temperature Sensors High Temperature K-Thermocouple
These Temperature Sensors Thermocouple type K are an economy item, The price is cheaper than the MISUMI standard product.They offer a wide variety of sizes to choose from.
[Feature]
● Temperature Sensors : Thermocouple Type K
● Sheath, Protection Tube Diameter (mm.): 1.5, 2, 3 and 5
● Protection Tube Length (mm.): 30, 50 and 100
● Wire Length (m.): 2
● Temperature Range (°C) : 0-550, 0-650, 0-750 and 0- 800
● Crimp Terminal Type: Y-Shaped 2 sets
[Application]
It is used in a variety of application such as heat treatment, packaging industry , plastic industry , and so on.



Temperature Sensors Dimensional Drawing

Dimensional Drawing
Temperature Sensors For more information on product dimensional drawings, please refer to the product catalog.

Temperature Sensors Specification Table

Temperature Sensors Tpye d (mm) L (mm) H (mm) F(m) Shape Temperature Range
C-MSND 1.5 100 7.1 2 K type thermocouples 0 to 550℃
2 50 0 to 650℃
3 30 0 to 750℃
50
100
5 100 9.6 0 to 800℃

Temperature Sensors Product Overview

Temperature Sensors
The thermocouple consists of two wires made of different materials, which are welded together at the end. After the ambient temperature of the unheated part is measured, the temperature of the heating point can be accurately known. Because it must have the conductor made of two different materials, it is called the thermocouple. The thermocouples made of different materials can be used in different temperature ranges, and their sensitivities are different from each other. The sensitivity of a thermocouple refers to the change in the output potential difference when the temperature of the heating point changes by 1°C. For most metal-supported thermocouples, this value is between 5-40 µV/°C.

PT100
Pt100 is a platinum thermal resistance, and its resistance value is proportional to the change of temperature. 100 after PT means that its resistance value is 100 ohms at 0°C and about 138.5 ohms at 100°C.

Temperature Sensors Product Feature

Genuine material and guaranteed wire diameter
Fast temperature response
More detailed improvements
Various mounting head types

Temperature Sensors Related Products

Temperature Sensors Precautions

PrecautionsTemperature Sensors Precautions for use
The sheath type can be bent (minimum bending radius: sheath diameter × 5), but the part in the temperature detection range (20 mm of the front end) cannot be bent. The protective tube type cannot be bent, otherwise the temperature cannot be measured correctly.
To extend the thermocouple lead wire, please use the compensation lead wire.
Please strictly observe the heat resistant temperature of each part in product page. Please note that even the upper limit of the temperature measurement is very high, malfunctions such as wire breakage may occur if the heat-resistant Temperature Sensors is exceeded.
Do not apply large external force or vibration.
Please note the heat resistance temperature of the sleeve part.
The upper limit temperature measured is the value at the temperature measuring point (the front end of the sheath). During the actual measurement, please note that the temperature of the sleeve should not exceed the heat-resistant temperature (80°C). Otherwise, the cable make break due to thermal expansion in the sleeve.
 Especially when the temperature of the object heated exceeds 100℃, please try to select the specification with the long length L of the sheath, and try to keep the sleeve part away from the object heated.
Please keep the upper limit of the temperature below the temperature measurement range of the product. If the bushing temperature exceeds the heat-resistant temperature, it is very easy to cause the breakage of the Temperature Sensors measurement wire.
If the temperature of heat generating parts exceeds 100°C, please choose the specification with a front end as long as possible.

Temperature Sensors Usage Method

Temperature Sensors Couples should not be installed too close to the door and heating place, and the insertion depth should be at least 8 to 10 times the diameter of the protection tube; the interval between the thermocouple protection bushing and the wall is not filled with insulation material, resulting in furnace heat overflow or cold air intrusion. Therefore, the interval between the thermocouple protection bushing and the furnace wall hole should be blocked with refractory mud or asbestos cord or other insulation materials so that the accuracy of temperature measurement will not be affected by hot and cold air convection; The cold end of the thermocouple is too close to the furnace, causing the temperature to rise above 100℃; thermocouples should be as far away as possible from strong magnetic and electric fields, so the thermocouples and power cable should not be installed in the same conduit to avoid deviation caused by interference; thermocouples can not be installed in the area where the measured medium rarely flow. Thermocouples must be installed against the direction of the flow and in full contact with the gas when the tube gas temperature is measured by thermocouples.

Temperature Sensors Brand introduction

MISUMI, the head office company, has been providing customers with various high-quality parts such as automation parts, mold parts, electronic parts, tool & consumables, etc. quickly and accurately since its establishment in Japan in 1963. By compiling product catalogs independently and establishing a marketing system for direct sales of products, a low-cost business operation mode has been created, and by making annual product plans according to customers' opinions and requirements, MISUMI brand-name products with high quality level have been continuously developed

Part Number 

CAD Data download and 3D preview are not available because the part number has not yet been determined.

  • *In order to open the CAD Data download and 3D preview screen, the part number must be fixed.
  • Please confirm the part number from "Specification / Dimension"on the left side, and then perform the CAD Data Download / 3D Preview operation.
Loading...
Part Number
C-MSND1.5-100
C-MSND2-50
C-MSND3-30
C-MSND3-50
C-MSND3-100
C-MSND5-100
Part NumberMinimum order quantityVolume DiscountDays to ShipSheath, Protection Tube Diameter
(Ø)
Sheath, Protecting Tube Length L
(mm)
Operating Temperature Range
(°C)
Sheath, Protecting Tube Band Diameter D
(Ø)
1 Piece(s)Available 10 Day(s) 1.51000~5507.1mm
1 Piece(s)Available 10 Day(s) 2500~6507.1mm
1 Piece(s)Available Same day 3300~7507.1mm
1 Piece(s)Available Same day 3500~7507.1mm
1 Piece(s)Available 10 Day(s) 31000~7507.1mm
1 Piece(s)Available 10 Day(s) 51000~8009.6mm

Loading...

  1. 1

Dimensional Drawing
Dimensional Drawing
For more information on product dimensional drawings, please refer to the product catalog.
Specification Table
TpyedLH (mm)F(m)ShapeTemperature Range
C-MSND1.51007.12K type thermocouples0 to 550℃
2500 to 650℃
3300 to 750℃
50
100
51009.60 to 800℃

Basic Information

Type of Temperature Sensor Thermocouple Type of Thermocouple K Thermocouple Measurement Object Temperature Sensor
Temperature Measurement Contact Point Isolated Neutral Type Number of Elements 1 Type of Terminal Y-Shaped Crimp Terminal
Lead Wire Length (F)(m) 2

Frequently asked question (FAQ)

Question: What are the main types of sensors currently sold by MISUMI?
Answer: Photoelectric sensors, proximity sensors, pressure sensors, temperature sensors, etc.
Question: What is a photo microsensors?
Answer: With an amplifier, an emitter and a receiver built in its integrated main body, it is a sensor that is easy to install and adjust, usually designed for detecting the passage of workpieces on the conveying line and for positioning workpieces, etc.
Question: What are the features of the photoelectric sensor?
Answer: 1. The action (response time) is very fast because light is used as the medium.
2. It has a longer detection distance than the light sensor and allows for remote detection.
3. Objects made of almost any material can be detected as long as they reflect light.
Question: What are the detection methods of the photoelectric sensor?
Answer: Transmittance type, regression reflection type, diffusion reflection type, limited reflection type, etc.

Check other FAQ (1 items) Hide